MEAN WELL SE-600-5 Single Output Power Supply Owner’s Manual

October 30, 2023
MEAN WELL

MEAN WELL SE-600-5 Single Output Power Supply

600W Single Output Power Supply – SE-600 Series

The SE-600 series power supply is a reliable and efficient product that provides a single output of up to 600W. It is designed to meet safety standards such as IS 15885(Part 2/Sec13) and K60950-1, except for the 48V model which is not included. The 12V and 24V models also comply with IEC62368-1 (Note.5).

Specifications

  • Model: SE-600-5, SE-600-12, SE-600-15, SE-600-24, SE-600-27, SE-600-36, SE-600-48
  • Output:
    • DC Voltage: 5V, 12V, 15V, 24V
    • Rated Current: 100A, 50A, 40A, 25A
    • Current Range: 0~100A, 0~50A, 0~40A, 0~25A
    • Rated Power: 500W (for SE-600-5), 600W (for all other models)
    • Ripple & Noise (max.): 150mVp-p (for all models)
    • Voltage Adj. Range: 4.75~5.5V (for SE-600-5), 10~13.5V (for SE-600-12), 13.5~16.5V and 22~26.4V (for SE-600-15 and SE-600-24 respectively)
    • Line Regulation, Load Regulation, Setup, Rise Time: Refer to user manual
    • Hold Up Time (Typ.): 20ms/230VAC, 16ms/115VAC at full load
    • Voltage Range: 90~132VAC / 180~264VAC selected by switch or 254~370VDC
    • Frequency Range: 47~63Hz
  • Input:
    • Efficiency (Typ.): 78% (for SE-600-5), 83% (for SE-600-12), 84% (for SE-600-15), 87% (for all other models)
    • AC Current (Typ.): 12A/115VAC, 7.5A/230VAC
    • Inrush Current (Typ.): 30A/115VAC, 60A/230VAC
    • Leakage Current: Refer to user manual

Product Usage Instructions

  1. Before use, ensure that the input voltage range is set correctly according to your local power supply specifications. Use the switch to select between 90~132VAC / 180~264VAC or 254~370VDC as appropriate.
  2. Connect the power supply to your device using appropriate cables and connectors. Ensure that the polarity is correct to avoid damage to your device.
  3. Adjust the output voltage as required using the voltage adjustment range specified for your model in the specifications section of the user manual.
  4. Power on your device and monitor the output voltage to ensure that it remains within the specified range. If there are any issues, refer to the troubleshooting section of the user manual or contact customer support for assistance.
  5. When not in use, turn off the power supply and disconnect it from your device to avoid unnecessary power consumption and potential damage to your device.

Features

  • AC input active surge current limiting
  • AC input range selected by switch
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Forced air cooling by built-in DC fan
  • High power density 4.9w/in’
  • Built-in remote sense function
  • UL approved
  • Low cost
  • 2 years warranty

SPECIFICATION

MODEL| SE-600-5| SE-600-12| SE-600-15| SE-600-24| SE-600-27| SE-600-36| SE-600-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 36V| 48V
RATED CURRENT| 100A| 50A| 40A| 25A| 22.2A| 16.6A| 12.5A
CURRENT RANGE| 0 ~ 100A| 0 ~ 50A| 0 ~ 40A| 0 ~ 25A| 0 ~ 22.2A| 0 ~ 16.6A| 0 ~ 12.5A
RATED POWER| 500W| 600W| 600W| 600W| 599.4W| 597.6W| 600W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.75 ~ 5.5V| 10 ~ 13.5V| 13.5 ~ 16.5V| 22 ~ 26.4V| 24 ~ 30V| 32 ~ 40V| 43 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 50ms/230VAC            1000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)| 20ms/230VAC            16ms/115VAC at full load
INPUT| VOLTAGE RANGE| 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 78%| 83%| 84%| 87%| 87%| 87%| 88%
AC CURRENT (Typ.)| 12A/115VAC          7.5A/230VAC
INRUSH CURRENT (Typ.)| 30A/115VAC           60A/230VAC
LEAKAGE CURRENT| <2.0mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 125% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 5.75 ~ 6.3V| 13.8 ~ 16.2V| 18 ~ 21V| 27.6 ~ 32.4V| 31 ~ 36.5V| 42 ~ 50V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| 85℃±5℃ (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -20 ~ +60℃ (Refer to output load derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS**| CB IEC62368-1, UL60950-1,UL62368-1, EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only),

IS13252(Part1)/IEC60950-1(except for 48V) approved; Design refer to BS EN/EN62368-1

WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:1.5KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
OTHERS| MTBF| 1529.1K hrs min.        Telcordia TR/SR-332 (Bell core) ;  204.2K hrs min.          MIL-HDBK-217F (25℃)
DIMENSION| 24712763.5mm (LWH)
PACKING| 2.1Kg; 6pcs/13.4Kg/1.03CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 of & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The ambient temperature derating of 3.5°C/1000m with finless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  5. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions:
    • the end-devices is used within the European Union, and
    • the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
    • the power supply is:
    • installed in end-devices with average or continuous input power greater than 75W, or
    • belong to part of a lighting system

Exception
Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2

  • professional equipment with a total rated input power greater than 1000W;
  • symmetrically controlled heating elements with a rated power less than or equal to 200W

Product Liability Disclaimer: For detailed information. please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-SE-600-5-Single-Output-Power-Supply-03
AC input terminal

Pin No. Assignment
1 AC/L
2 AC/N
3 FG

DC Output terminal :

Pin No. Assignment
1~3 +V
4~6 -V

RS Connector (CN4) : JST B-XH or equivalent

Pin No. Assignment Mating Housing Terminal
1 +S JST XHP or equivalent JST SXH-001T or equivalent
2 -S
  • **Block Diagram

MEAN-WELL-SE-600-5-Single-Output-Power-Supply-04

**

  • Derating Curve
    MEAN-WELL-SE-600-5-Single-Output-Power-Supply-05

  • Static Characteristics****


Made in China
MEAN-WELL-SE-600-5-Single-Output-Power-Supply-02

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)