MEAN WELL HLG-600H-24B LED Driver Installation Guide

September 6, 2024
MEAN WELL

600W Constant Voltage + Constant Current LED Driver

HLG-600H series


User’s Manual

MEAN WELL A - 1

Features

  • Constant Voltage + Constant Current mode output
  • Metal housing with class I design
  • Standby power consumption <0.5W at remote off
  • IP67/ IP65 rating for indoor or outdoor installations
  • Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off)
  • Typical lifetime > 62000 hours
  • 7 years warranty

Applications

  • LED high-bay lighting
  • Parking space lighting
  • LED fishing lamp
  • LED greenhouse lighting
  • Type “HL” for use in Class I, Division 2 hazardous (Classified) location.

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

HLG-600H series is a 600W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-600H operates from 90 ~ 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 96%, with the fanless design, the entire series is able to operate for -40°C ~ +90°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-600H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.

Model Encoding

  1. Function options
  2. Rated output voltage (12V/15V/20V/24V/30V/36V/42V/48V/54V)
  3. Rated wattage
  4. Series name

Type

| IP Level| Function| Note
---|---|---|---
A|

IP65

| Io and Vo adjustable through built-in potentiometer|

In Stock

B|

IP67

| 3 in 1 dimming function (0~10VDC, 10V PWM signal and resistance)|

In Stock

AB|

IP65

| Io and Vo adjustable through built-in potentiometer &
3 in 1 dimming function (0~10VDC, 10V PWM signal and resistance)|

In Stock

Blank|

IP67

| Io and Vo fixed|

In Stock

SPECIFICATION

MODEL HLG-600H-12 HLG-600H-15 HLG-600H-20
OUTPUT DC VOLTAGE 12V 15V

CONSTANT CURRENT REGION

Note.4

| 6 ~12V| 7.5 ~ 15V| 10 ~ 20V
RATED CURRENT| 40A| 36A| 28A
RATED POWER| 480W| 540W| 560W
RIPPLE & NOISE (max.)

Note.2

| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A-Type only (via built-in potentiometer)
10.2 ~ 12.6V| 12.7 ~ 15.8V| 17 ~ 21V
CURRENT ADJ. RANGE| Adjustable for A-Type only (via built-in potentiometer)
20 ~ 40A| 18 ~ 36A| 14 ~ 28A
VOLTAGE TOLERANCE

Note.3

| ±3.0%| ±2.0%| ±1.5%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±1.0%
SETUP, RISE TIME

Note.6

| 500ms, 80ms/ 115VAC, 230VAC
HOLD UP TIME (Typ.)| 15ms / 115VAC, 230VAC
INPUT| VOLTAGE RANGE

Note.5

| 90 ~ 305VAC   127 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
EFFICIENCY (Typ.)| 230VAC| 92%| 93.5%| 94.5%
277VAC| 92.5%| 93.5%| 94.5%
AC CURRENT (Typ.)| 7A / 115VAC   3.3A / 230VAC   2.9A / 277VAC
INRUSH CURRENT (Typ.)| COLD START 70A(twidth=1000 μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY POWER CONSUMPTION| <0.5W at remote off
PROTECTION| OVER CURRENT

Note.4

| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 13 ~ 16V| 16.5 ~ 20.5V| 22 ~ 26V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
FUNCTION| REMOTE ON/OFF CONTROL| Power on : “High” >2 ~ 5V or Open circuit   Power off : “Low” <0 ~ 0.5V or Short circuit
5V STANDBY| 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT| WORKING TEMP.| Tcase= -40 ~ +90℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase= +90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 55℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note 10)| SAFETY STANDARDS

Note.7

| UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP65 or IP67, J61347-1, J61347-2-13, GB19510.1,GB19510.14, EAC TP TC 004, AS/NZS 60950.1(by CB)(AB type except ),KC61347-1, KC61347-2-13(for 24A,36A,48A,54A only) approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION

Note.7

| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3, EAC TP TC 020; GB/T17743,GB17625.1, KC KN15, KN61547(for 24A,36A,48A,54A only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020; KC KN15, KN61547(for 24A,36A,48A,54A only)
OTHERS| MTBF| 913.4K hrs min.   Telcordia SR-332 (Bellcore) ; 76.9K hrs min.   MIL-HDBK-217F (25℃)
DIMENSION| 28014448.5mm (LWH)
PACKING| 3.9Kg; 4pcs/16.6Kg/0.9CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25°C of ambient temperature. 
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Please refer to “DRIVING METHODS OF LED MODULE.
  5. Derating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 
  6. Length of set up time is measured at fist cold start. Turning ON/OFF the driver may lead to increase of the set up time. 
  7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model. Please contact MEAN WELL for details. 
  8. This series meets the typical Ife expectancy of >62,000 hours of operation when Tcase, particularly point (or TMP, per DLC), is about 75°C or less.
  9. Please refer to the warranty statement on MEAN WELL’s website http://www.meanwell.com 
  10. The driver is considered a component which will be installed into a final equipment. Al the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must b re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com
  11. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  12. For any application note and IP water proof function installation caution, please refer our user manual before using.
    https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL HLG-600H-24 HLG-600H-30 HLG-600H-36
OUTPUT DC VOLTAGE 24V 30V

CONSTANT CURRENT REGION

Note.4

| 12 ~ 24V| 15 ~ 30V| 18 ~ 36V
RATED CURRENT| 25A| 20A| 16.7A
RATED POWER| 600W| 600W| 601.2W
RIPPLE & NOISE (max.)

Note.2

| 150mVp-p| 200mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A-Type only (via built-in potentiometer)
20.4 ~ 25.2V| 25.5 ~ 31.5V| 30.6 ~ 37.8V
CURRENT ADJ. RANGE| Adjustable for A-Type only (via built-in potentiometer)
12.5 ~ 25A| 10 ~ 20A| 8.3 ~ 16.7A
VOLTAGE TOLERANCE

Note.3

| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME

Note.6

| 500ms, 80ms/ 115VAC, 230VAC
HOLD UP TIME (Typ.)| 15ms / 115VAC, 230VAC
INPUT| VOLTAGE RANGE

Note.5

| 90 ~ 305VAC   127 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
EFFICIENCY (Typ.)| 230VAC| 95%| 95%| 95.5%
277VAC| 95%| 95%| 95.5%
AC CURRENT (Typ.)| 7A / 115VAC   3.3A / 230VAC   2.9A / 277VAC
INRUSH CURRENT (Typ.)| COLD START 70A(twidth=1000 μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY POWER CONSUMPTION| <0.5W at remote off
PROTECTION| OVER CURRENT

Note.4

| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 26 ~ 30V| 32.5 ~ 36.5V| 39.5 ~ 43.5V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
FUNCTION| REMOTE ON/OFF CONTROL| Power on : “High” >2 ~ 5V or Open circuit   Power off : “Low” <0 ~ 0.5V or Short circuit
5V STANDBY| 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT| WORKING TEMP.| Tcase= -40 ~ +90℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase= +90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 55℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note 10)| SAFETY STANDARDS

Note.7

| UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP65 or IP67, J61347-1, J61347-2-13, GB19510.1,GB19510.14, EAC TP TC 004, AS/NZS 60950.1(by CB)(AB type except ),KC61347-1, KC61347-2-13(for 24A,36A,48A,54A only) approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION

Note.7

| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3, EAC TP TC 020; GB/T17743,GB17625.1, KC KN15, KN61547(for 24A,36A,48A,54A only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020; KC KN15, KN61547(for 24A,36A,48A,54A only)
OTHERS| MTBF| 913.4K hrs min.   Telcordia SR-332 (Bellcore) ; 76.9K hrs min.   MIL-HDBK-217F (25℃)
DIMENSION| 28014448.5mm (LWH)
PACKING| 3.9Kg; 4pcs/16.6Kg/0.9CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25°C of ambient temperature. 
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Please refer to “DRIVING METHODS OF LED MODULE.
  5. Derating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 
  6. Length of set up time is measured at fist cold start. Turning ON/OFF the driver may lead to increase of the set up time. 
  7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model. Please contact MEAN WELL for details. 
  8. This series meets the typical Ife expectancy of >62,000 hours of operation when Tcase, particularly point (or TMP, per DLC), is about 75°C or less.
  9. Please refer to the warranty statement on MEAN WELL’s website http://www.meanwell.com 
  10. The driver is considered a component which will be installed into a final equipment. Al the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must b re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com
  11. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  12. For any application note and IP water proof function installation caution, please refer our user manual before using.
    https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL HLG-600H-42 HLG-600H-48 HLG-600H-54
OUTPUT DC VOLTAGE 42V 48V

CONSTANT CURRENT REGION

Note.4

| 21 ~ 42V| 24 ~ 48V| 27 ~ 54V
RATED CURRENT| 14.3A| 12.5A| 11.2A
RATED POWER| 600.6W| 600W| 604.8W
RIPPLE & NOISE (max.)

Note.2

| 250mVp-p| 250mVp-p| 350mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A-Type only (via built-in potentiometer)
35.7 ~ 44.1V| 40.8 ~ 50.4V| 45.9 ~ 56.7V
CURRENT ADJ. RANGE| Adjustable for A-Type only (via built-in potentiometer)
7.1 ~ 14.3A| 6.2 ~ 12.5A| 5.6 ~ 11.2A
VOLTAGE TOLERANCE

Note.3

| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME

Note.6

| 500ms, 80ms/ 115VAC, 230VAC
HOLD UP TIME (Typ.)| 15ms / 115VAC, 230VAC
INPUT| VOLTAGE RANGE

Note.5

| 90 ~ 305VAC   127 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
EFFICIENCY (Typ.)| 230VAC| 96%| 96%| 96%
277VAC| 96%| 96%| 96%
AC CURRENT (Typ.)| 7A / 115VAC   3.3A / 230VAC   2.9A / 277VAC
INRUSH CURRENT (Typ.)| COLD START 70A(twidth=1000 μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY POWER CONSUMPTION| <0.5W at remote off
PROTECTION| OVER CURRENT

Note.4

| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 46 ~ 50V| 52.5 ~ 56.5V| 59 ~ 63V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
FUNCTION| REMOTE ON/OFF CONTROL| Power on : “High” >2 ~ 5V or Open circuit   Power off : “Low” <0 ~ 0.5V or Short circuit
5V STANDBY| 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT| WORKING TEMP.| Tcase= -40 ~ +90℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase= +90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 55℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note 10)| SAFETY STANDARDS

Note.7

| UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP65 or IP67, J61347-1, J61347-2-13, GB19510.1,GB19510.14, EAC TP TC 004, AS/NZS 60950.1(by CB)(AB type except ),KC61347-1, KC61347-2-13(for 24A,36A,48A,54A only) approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION

Note.7

| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3, EAC TP TC 020; GB/T17743,GB17625.1, KC KN15, KN61547(for 24A,36A,48A,54A only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020; KC KN15, KN61547(for 24A,36A,48A,54A only)
OTHERS| MTBF| 913.4K hrs min.   Telcordia SR-332 (Bellcore) ; 76.9K hrs min.   MIL-HDBK-217F (25℃)
DIMENSION| 28014448.5mm (LWH)
PACKING| 3.9Kg; 4pcs/16.6Kg/0.9CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25°C of ambient temperature. 
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Please refer to “DRIVING METHODS OF LED MODULE.
  5. Derating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 
  6. Length of set up time is measured at fist cold start. Turning ON/OFF the driver may lead to increase of the set up time. 
  7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model. Please contact MEAN WELL for details. 
  8. This series meets the typical Ife expectancy of >62,000 hours of operation when Tcase, particularly point (or TMP, per DLC), is about 75°C or less.
  9. Please refer to the warranty statement on MEAN WELL’s website http://www.meanwell.com 
  10. The driver is considered a component which will be installed into a final equipment. Al the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must b re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com
  11. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  12. For any application note and IP water proof function installation caution, please refer our user manual before using.
    https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

BLOCK DIAGRAM

fosc : 100KHz(5V)
70KHz(12V~54V)

MEAN WELL HLG-600H-24B LED Driver - a2

DRIVING METHODS OF LED MODULE

※ This series is able to work in either Constant Current mode (a direct drive way) or
Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.

  1. (A) Constant Voltage area
  2. (B) Constant Current region
  3. In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
    Should there be any compatibility issues, please contact MEAN WELL.

DIMMING OPERATION

MEAN WELL HLG-600H-24B LED Driver - b1

3 in 1 dimming function (for B/AB-Type)

  • Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
  • Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
  • Dimming source current from power supply: 100μA (typ.)

Applying additive 0 ~ 10VDC

“DO NOT connect “DIM- to -V”

  1. Additive Voltage

Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):

“DO NOT connect “DIM- to -V”

  1. Additive PWM signal

Applying additive resistance:

“DO NOT connect “DIM- to -V”

  1. Additive Resistance

Note :

  1. Min. dimming level is about 6% and the output current is not defined when 0%< Iout<6%.
  2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.

OUTPUT LOAD vs TEMPERATURE

If HLG-600H operates in constant current mode with the rated current, the maximum workable Ta is 55℃.

STATIC CHARACTERISTICS

※ De-rating is needed under low input voltage.

POWER FACTOR(PF) CHARACTERISTIC

Tcase at 80℃

Constant Current Mode

TOTAL HARMONIC DISTORTION (THD)

※ 48V Model, Tcase at 80℃

EFFICIENCY vs LOAD

HLG-600H series possess superior working efficiency that up to 96% can be reached in field applications.
※ 48V Model, Tcase at 80℃

LIFETIME

MECHANICAL SPECIFICATION

Case No. 228    Unit: mm

A-Type

MEAN WELL HLG-600H-24B LED Driver - b15

• : Max. Case Temperature

MEAN WELL HLG-600H-24B LED Driver - b16

B-Type

MEAN WELL HLG-600H-24B LED Driver - b17

• : Max. Case Temperature

MEAN WELL HLG-600H-24B LED Driver - b18

AB-Type

MEAN WELL HLG-600H-24B LED Driver - b19

• : Max. Case Temperature

MEAN WELL HLG-600H-24B LED Driver - b20

Blank-Type

MEAN WELL HLG-600H-24B LED Driver - b21

• : Max. Case Temperature

MEAN WELL HLG-600H-24B LED Driver - b22

INSTALLATION MANUAL

Please refer to : http://www.meanwell.com/manual.html

File Name:HLG-600H-SPEC   2023-12-22

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals