MEAN WELL HRPG-1000N3 1000W Ultra-High Peak Power Supply
Product Information
- Product Name: 1000W Ultra-High Peak Power Supply
- Model: HRPG-1000N3 series
- User’s Manual: Included
- Safety Certifications: UL62368-1, BS EN/EN62368-1, IEC62368-1, TPTC004, EAC TP TC 004 approved
- Features:
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 94%
- Withstand 300VAC surge input for 5 seconds
- Up to 320% peak power capability
- Protections: Short circuit/Overload/Over voltage/Over temperature
- Built-in cooling fan ON-OFF control
- Current sharing up to 4000W (3+1)
- Built-in DC OK/remote ON-OFF/remote sense functions
- Standby power 5V@0.3A
- No load power consumption: 0.95/230VAC PF>0.99/115VAC at full load
- Dimensions: 21810561.5mm (LWH)
- Weight: 1.46Kg
Product Usage Instructions
- Input: Connect the power supply to a universal AC input source.
- Output: Connect the appropriate DC output cables to your device.
- Protections: The power supply provides protection against short circuits, overloads, over-voltage, and over-temperature. If any of these protections are triggered, the output voltage will shut down. To recover, re-power on after resolving the issue.
- Current Sharing: If you have multiple units (up to 3+1), you can enable current sharing for a total power output of up to 4000W. Refer to the function manual for more details.
- Remote ON-OFF Control: To turn the power supply on, short the remote ON-OFF control. To turn it off, open the connection. Please refer to the function manual for more details.
- Remote Sense Function: The power supply has a remote sense function that compensates for voltage drop on the load wiring. This helps maintain accurate voltage levels. Please refer to the function manual for more details.
- Standby Power: The power supply provides a standby power of 5V at 0.3A.
- Fan Control: The cooling fan of the power supply is controlled by NTC (RT50) or when the load reaches a minimum of 30%.
- Working Temperature and Humidity: The power supply can operate in temperatures ranging from -40°C to +70°C. The working humidity should be between 20% and 90% RH (non-condensing).
- Safety Standards: The power supply complies with UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, AS/NZS62368.1, and EAC TP TC 004 safety standards.
Please consult the user’s manual for complete instructions and additional information.
Features
- Universal AC input/Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 94%
- Withstand 300VAC surge input for 5 seconds
- Up to 320% peak power capability
- Protections: Short circuit/Overload/Over voltage/Over temperature
- Built-in cooling fan ON-OFF control
- Current sharing up to 4000W (3+1)
- Built-in DC OK/remote ON-OFF/remote sense functions
- Standby power 5V@0.3A
- No load power consumption<0.85W (Note.7)
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging equipment
- RF application
- For inductive and capacitive load
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
HRPG-1000N3 series is a 1000W single output AC/DC with ultra-high peak power supply. This series operates for 90~264 VAC input voltage and offers models with different rated voltages ranging between 12 and 48 V that can satisfy the demands of all kinds of industrial equipment. Each model is cooled by the built-in fan with speed control, working for a temperature up to 70°C. Moreover, HRPG-1000N3 has various built-in functions such as auxiliary power, remote sense, and remote on-off control, offering vast design flexibility for industrial applications. It can provide 320% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Model Encoding
SPECIFICATION
MODEL| HRPG-1000N3-12| HRPG-1000N3-24| HRPG-1000N3-36|
HRPG-1000N3-48
---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 80A| 42A| 28A| 21A
CURRENT RANGE| 0 ~ 80A| 0 ~ 42A| 0 ~ 28A| 0 ~ 21A
RATED POWER| 960W| 1008W| 1008W| 1008W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 200mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 11 ~ 14V| 22 ~ 28V| 32 ~ 38V| 46 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at
full load
HOLD UP TIME (Typ.)**| 16ms/230VAC 16ms/115VAC at full load
INPUT
| VOLTAGE RANGE| 90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC PF>0.99/115VAC at full
load
EFFICIENCY (Typ.)| 91.5%| 93%| 93%| 94%
AC CURRENT (Typ.)| 8.5A/115VAC 5A/230VAC
INRUSH CURRENT (Typ.)| 25A/115VAC 40A/230VAC
LEAKAGE CURRENT| <1.2mA / 240VAC
PROTECTION
| ****
OVERLOAD **Note.4**
| Output power >105% rated for more than 5 seconds then shut down o/p
voltage, re-power on to recover
Output power > 320% rated then shut down o/p voltage, re-power on to recover
for 12V
Output power > 350% rated then shut down o/p voltage, re-power on to recover for 24V, 36V and 48V
OVERVOLTAGE
| 14.5 ~ 16.5V| 29 ~ 33V| 39 ~ 46V| 58 ~ 65V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION
| CURRENT SHARING| Up to 4000W or (3+1) units. Please refer to the
function manual.
REMOTE ON-OFF CONTROL| Power ON: short; Power OFF: open. Please refer to
the function manual.
REMOTE SENSE| Compensate voltage drop on the load wiring up to 0.5V.
Please refer to the function manual.
DC-OK SIGNAL| The TTL signal out, PSU turns on = 3.3 ~ 5.6V; PSU turns
off = 0 ~ 1V. Please refer to the function manual.
5V STANDBY| 5VSB : 5V@0.3A ; tolerance±5%, ripple :
50mVp-p(max.)
FAN CONTROL| Fan on/off by NTC(RT50) or 30% load min.
ENVIRONMENT
| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS| UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS
EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32)| Class B
Radiated| BS EN/EN55032 (CISPR32)| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 4, 2KV/Line-Line 4KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 989.2K hrs min. Telcordia SR-332 (Bellcore) ;
130.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 21810561.5mm (LWH)
PACKING| 1.46Kg;8pcs/12.8Kg/1.58CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation, and load regulation.
- After the output protection, restart the device about 30 seconds after the input disconnection interval.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time.
- No load power consumption<0.85W when RC+ & RC- (CN100 pin3,4) open.
- The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*?00mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
- PFC: 65KHz
- PWM: 90KHz
Derating Curve
Output Derating VS Input Voltage
Function Manual
- Peak Power
- Pav: Average output power (W)
- Ppk: Peak output power (W)
- Pnpk: Non-peak output power-(W)
- Prated: Rated output power (W)
- t: Peak power width (sec)
- T: Period (sec)
- For example (24V model):
Function Description of CN100
Pin No. | Function | Description |
---|---|---|
1 | AUXG | Auxiliary voltage output ground. |
2 | AUX | Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The |
maximum load current is 0.3A. This output is not controlled by the “remote
ON/OFF control”.
3| RC+| Turns the output on and off by electrical or dry contact between pin 4
(RC-), Short: Power ON, Open: Power OFF.
4| RC-| Remote control ground.
5| CS| Current sharing signal. When units are connected in parallel, the CS
pins of the units should be connected to allow current balance between units.
6,8| GND| This pin connects to the negative terminal(-V). Return for DC-OK
signal output.
7| DC-OK| DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND).
High when PSU turns on.
9| +S| Positive sensing. The +S signal should be connected to the positive
terminal of the load. The +S and -S leads should be twisted in pairs to
minimize the noise pick-up effect. The maximum line drop compensation is 0.5V.
10| -S| Negative sensing. The -S signal should be connected to the negative
terminal of the load. The -S and +S leads should be twisted in pairs to
minimize the noise pick-up effect. The maximum line drop compensation is 0.5V.
Function Manual
-
Remote Sense
The remote sensing compensates for voltage drop on the load wiring up to 0.5V . -
DC-OK Signal
DC- OK signal is a TTL level signal. High when PSU turns on.Between DC- OK(pin7) and GND(pin6,8)| Output Status
---|---
3.3 ~ 5.6V| ON
0 ~ 1V| OFF -
Remote ON-OFF Control
Between RC+(pin3) and RC-(pin4)| Output Status
---|---
SW ON (Short)| ON
SW OFF (Open)| OFF -
Current Sharing
HRPG-1000N3 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below :- The power supplies should be paralleled using short and large-diameter wiring and then connected to the load.
- The difference of output voltages among parallel units should be less than 0.2V.
- The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit) (Number of units)××0.9
- When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of units) the current shared among units may not be fully balanced.
Mechanical Specification
Case No. 977H Unit:mm
AC Input Terminal Pin No. Assignment
Pin No. | Assignment |
---|---|
1 | AC/L |
2 | AC/N |
3 | FG |
DC Output Terminal Pin No. Assignment
Pin No. | Assignment |
---|---|
1~3 | +V |
4~6 | -V |
Connector Pin No. Assignment(CN100): HRS DF11-10DP-2DS or equivalent
Pin No. | Assignment | Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|---|---|
1 | AUXG | 6,8 | GND |
HRS DF11-10DS
or equivalent
|
HRS DF11-**SC
or equivalent
2| AUX| 7| DC-OK
3| RC+| 9| +S
4| RC-| 10| -S
5| CS| |
Installation Manual
Please refer to: http://www.meanwell.com/manual.html.