MEAN WELL HRP-600N series Enclosed Power Supplies Instruction Manual

August 29, 2024
MEAN WELL

600W Single Output with PFC Function
HRP-600N serie

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.94
  • 250% peak power capability
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote sense function
  • 5 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Diagnostic or biological facilities
  • Test or measurement systems
  • Telecommunication equipment

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

HRP-600N is a 600W single output type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan ON-OFF control, working for the temperature up to 70 Moreover, .℃ HRP-600N provides 250% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.

Model Encoding

SPECIFICATION

MODEL HRP-600N-12 HRP-600N-24 HRP-600N-36 HRP-600N-48
OUTPUT DC VOLTAGE 12V 24V 36V
RATED CURRENT 53A 27A 17.5A 13A
CURRENT RANGE 0 ~ 53A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A
RATED POWER 636W 648W 630W 624W
RIPPLE & NOISE (max.) Note.2 200mVp-p 150mVp-p 200mVp-p 240mVp-p
VOLTAGE ADJ. RANGE 10.2 ~ 13.8V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.3% ±0.2% ±0.2% ±0.2%
LOAD REGULATION ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1800ms, 50ms/230VAC          3600ms, 50ms/115VAC at full

load
HOLD UP TIME (Typ.)| 16ms/230VAC         16ms/115VAC at full load
INPUT| VOLTAGE RANGE  Note.4| 85 ~ 264VAC        120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.94/230VAC         PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 88%| 88%| 89%| 89%
AC CURRENT (Typ.)| 7.6A/115VAC        3.6A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC         70A/230VAC
LEAKAGE CURRENT| <1.5mA / 240VAC
PROTECTION| OVERLOAD| Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power on to recover
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 14.4 ~ 16.8V| 30 ~ 34.8V| 41.4 ~ 48.6V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

| DC OK SIGNAL| PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
FAN CONTROL (Typ.)| Load 35±15% or RTH2≧50℃ Fan on
ENVIRONMENT| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6| 5000 meters
SAFETY & EMC

(Note 5)

| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC  TP TC 004, AS/NZS 62368.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class B
Radiated| BS EN/EN55032| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact
RF field| BS EN/EN61000-4-3| Level 3, 10V/m
EFT/ Burst| BS EN/EN61000-4-4| Level 3, 2KV
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3, 10V
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage Dips and Interruptions|

BS EN/EN61000-4-11

| 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods
OTHERS| MTBF| 1380.8K hrs min.     Telcordia SR-332 (Bellcore) ; 191.3K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 21810561.5mm  (LWH)
PACKING| 1.39Kg;8pcs/12.1Kg/1.58CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Function Manual

  1. Remote Sense
    The remote sensing compensates voltage drop on the load wiring up to 0.5V.

  2. DC-OK Signal
    DC-OK signal is a TTL level signal. High when PSU turns on.Between DC-OK(pin1) and GND(pin2)| Output Status
    ---|---
    3.3 ~ 5.6V| ON
    0 ~ 1V| OFF

Pav : Average output power W()
Ppk : Peak output power W()
Pnpk : Non peak output power W-()
Prated : Rated output power W()
t : Peak power width sec
T: Period sec

  1. Peak Power

For example (12V model) :
Vin = 100V Duty_max = 25%
P = Prated = 636W av
P = 1200W
pk t5 sec
T ≤ 20 sec

Mechanical Specification

AC Input Terminal Pin No. Assignment

Pin No. Assignment
1 AC/L
2 AC/N
3 FG

DC Output Terminal Pin No.
Assignment

Pin No. Assignment
1~2 -V
3~4 +V

Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent

Pin No. Assignment Mating Housing Terminal
1 DC-OK

HRS DF11-4DS or equivalent

|

HRS DF11-**SC or equivalent

2| GND
3| +S
4| -S

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf