MEAN WELL DDR-60G-24 Industrial DC Converter Owner’s Manual

August 23, 2024
MEAN WELL

MEAN WELL DDR-60G-24 Industrial DC Converter

Feature

  • Width only 52.5mm (3SU)
  • 4:1 ultra-wide input range
  • -40~+85 C wide working temperature
  • No minimum load required
  • DC output adjustable (10%)
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc 1/0 isolation(Reinforced isolation)
  • 3 years warranty

Applications

  •  Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

GTIN CODE

Description

  • DDR-60 series is a 60W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra-slim width (52.5mm), 4:1 ultra-wide input voltage, -40 ~ +85°C wide operating temperature, 4KVdc 1/0 isolation, adjustable output voltage (‡ 10%) and full protective functions…etc.
  • This series has two input options: 9~36V /18~75V and various output options: 5V / 12V / 15V / 24V and can be used for industrial control, security control, communication systems and other fields. Suitable applications are
    DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable… etc.

Model Encoding

SPECIFICATION

MODEL| DDR-60G-5| DDR-60G-12| DDR-60G-15| DDR-60G-24| DDR-60L-5| DDR-60L-12| DDR-60L-15| DDR-60L-24
---|---|---|---|---|---|---|---|---







OUTPUT

| DC VOLTAGE| 5V| 12V| 15V| 24V| 5V| 12V| 15V| 24V
RATED CURRENT| 10.8A| 5A| 4A| 2.5A| 12A| 5A| 4A| 2.5A
CURRENT RANGE| 0 ~ 10.8A| 0 ~ 5A| 0 ~ 4A| 0 ~ 2.5A| 0 ~ 12A| 0 ~ 5A| 0 ~ 4A| 0 ~ 2.5A
RATED POWER| 54W| 60W| 60W| 60W| 60W| 60W| 60W| 60W
RIPPLE & NOISE (max.) **Note.2| 60mVp-p| 75mVp-p| 75mVp-p| 100mVp-p| 60mVp-p| 75mVp-p| 75mVp-p| 100mVp-p
VOLTAGE ADJ. RANGE| 4.5 ~ 5.5V| 9 ~ 13.2V| 13.5 ~ 16.5V| 21.6 ~ 28V| 4.5 ~ 5.5V| 9 ~ 13.2V| 13.5 ~ 16.5V| 21.6 ~ 28V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.5%| ±0.5%| ±0.5%| ±0.5%| ±1.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 120ms, 85ms at full load
HOLD UP TIME (Typ.)| G-type: 5ms@24Vdc input| L-type: 10ms@48Vdc input
EXTERNAL CAPACITANCE LOAD (Max.)**| 6800μF| 4700μF| 3300μF| 2200μF| 6800μF| 4700μF| 3300μF| 2200μF



INPUT

| VOLTAGE RANGE Note.4| 9 ~ 36Vdc| 18 ~ 75Vdc
EFFICIENCY (Typ.)| 87.5%| 91%| 91%| 91%| 87.5%| 91%| 92%| 92%
DC CURRENT (Typ.)| 3A /24Vdc| 1.5A /48Vdc
INRUSH CURRENT (Typ.)| 20A /24Vdc| 20A /48Vdc




PROTECTION

| ****

OVERLOAD

| 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed


OVER VOLTAGE

| 5.75 ~ 7V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 28.8 ~ 34V| 5.75 ~ 7V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 28.8 ~ 34V
Protection type: Shut down o/p voltage, re-power on to recover
REVERSE POLARITY| By internal MOSFET, no damage recovers automatically after fault condition removed


UNDER VOLTAGE LOCKOUT

| 24Vin (G-type):Power ON≥9V , OFF≤8.5V
48Vin (L-type):Power ON≥18V , OFF≤17V




ENVIRONMENT

| WORKING TEMP.| -40 ~ +85℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 5 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 5 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~60℃)
VIBRATION| Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE| 5000 meters









SAFETY & EMC

(Note 5)

| SAFETY STANDARDS| IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVdc
ISOLATION RESISTANCE| I/P-O/P>100M Ohms / 500Vdc / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class A
Radiated| BS EN/EN55032| Class A for 1m I/O cable , Class B for 30cm I/O cable
Voltage Flicker| BS EN/EN61000-3-3| —–







EMC IMMUNITY

| BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 3, 6KV contact; criteria A
Radiated| BS EN/EN61000-4-3| Level 3, 10V/m ; criteria A
EFT / Burst| BS EN/EN61000-4-4| Level 3, 2KV ; criteria A
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line ; criteria A
Conducted| BS EN/EN61000-4-6| Level 3, 10V ; criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m ; criteria A


OTHERS

| MTBF| 3261.6K hrs min.       Telcordia SR-332 (Bellcore) ; 611.1K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 52.59054.5mm (WHD)
PACKING| 216g; 60pcs/14Kg/0.97CUFT






NOTE

| 1.  All parameters NOT specially mentioned are measured at normal input (G:24Vdc, L:48Vdc), rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.

3.  Tolerance: includes set up tolerance, line regulation and load regulation.

4.  Derating may be needed under low input voltage. Please check the derating curve for more details.

5. The power supply is considered as an independent unit, but the final equipment still need to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

6.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Derating Curve

Output derating VS input voltage

Mechanical Specification

Installation Manual
Please refer to: http://www.meanwell.com/manual.html

FAQ

  • What are the applications of the DDR-60 series DC-DC converter?
  • The DDR-60 series is suitable for industrial control systems, semiconductor fabrication equipment, factory automation, electro-mechanical applications, wireless networks, and telecom or datacom systems.
  • How do I select the appropriate output voltage for my application?
  • Choose the output voltage (5V, 12V, 15V, or 24Vdc) based on your specific requirements and compatibility with your devices.
  • What is the warranty period for the DDR-60 series DC-DC converter?
  • The DDR-60 series comes with a warranty of 3 years from the date of purchase.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)