MEAN WELL GST18U05-P1J Reliable Green Industrial Adaptor
Product Information
Specifications
- Model: GST18U series
- DC Voltage: 5V, 7.5V, 9V, 12V, 15V, 18V, 24V, 28V, 48V
- Rated Power: 18W
- Input Voltage Range: 85 ~ 264VAC
- Efficiency: 81% – 89%
- Working Temperature: -30°C to +70°C
- Protections: Short circuit, Overload, Over voltage
Product Usage Instructions
-
Setup
Ensure the input voltage matches the specified range (85 ~ 264VAC) before connecting the adaptor. -
Connection
Plug the USA 2 pin AC plug into a compatible power outlet. -
Output Adjustment
Based on your device’s requirements, select the appropriate DC output voltage using the provided DC plug type (P1J standard model or other options). -
LED Indicator
The LED indicator will illuminate when the power is on, confirming the adaptor is operational. -
Safety Precautions
Avoid overloading the adaptor beyond the specified current limits to prevent damage. Ensure proper ventilation around the adaptor during operation.
Frequently Asked Questions (FAQ)
-
Q: Can I use this adaptor with consumer electronic devices?
A: Yes, this adaptor is suitable for consumer electronic devices such as smartphones, tablets, and laptops. -
Q: What is the warranty period for this product?
A: The adaptor comes with a 3-year warranty, ensuring peace of mind regarding its reliability and performance.
Features
- Global certificates
- Universal AC input/Full range
- 2 pole USA plug, Class II power unit
- No load power consumption< 0.075W
- Energy efficiency Level VI
- Comply with EISA 2007/DoE and NRCan
- Protections: Short circuit / Overload / Over voltage
- Fully enclosed plastic case
- Pass LPS
- -30 ~+70°C wide range working temperature
- LED indicator for power on
- Various DC plug quick adapter accessories available (Plug kit sold separately, please refer to: https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
GST18U is a highly reliable, 18W wall-mounted style single-output green adaptor series. This product is a class Il power unit (no FG), equipped with a 2-Pin standard USA AC power plug, adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With an efficiency of up to 89% and extremely low no-load power consumption below 0.075W, GST18U is compliant with USA EISA 2007/DoE and Canada NRCan. The supreme feature allows the adaptor to save energy when it is either in operating mode or standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GST18U is certified for international safety regulations.
Model encoding
SPECIFICATION
ORDER NO.| GST18U05- P1J| GST18U07- P1J|
GST18U09- P1J| GST18U12- P1J| GST18U15- P1J|
GST18U18- P1J| GST18U24- P1J| GST18U28- P1J|
GST18U48- P1J
---|---|---|---|---|---|---|---|---|---
OUTPUT| SAFETY MODEL NO.| GST18U05| GST18U07| GST18U09|
GST18U12| GST18U15| GST18U18| GST18U24| GST18U28| GST18U48
DC VOLTAGE **Note.2| 5V| 7.5V| 9V| 12V| 15V| 18V| 24V| 28V|
48V
RATED CURRENT| 3.0A| 2.0A| 2.0A| 1.50A| 1.20A| 1.0A| 0.75A| 0.64A|
0.375A
CURRENT RANGE| 0 ~ 3.0A| 0 ~ 2.0A| 0 ~2.0A| 0 ~ 1.50A| 0 ~ 1.20A| 0
~ 1.0A| 0 ~ 0.75A| 0 ~ 0.64A| 0 ~ 0.375A
RATED POWER (max.)| 15W| 15W| 18W| 18W| 18W| 18W| 18W| 18W| 18W
RIPPLE & NOISE (max.) Note.3| 80mVp-p| 80mVp-p| 80mVp-p|
80mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%|
±3.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION ****Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION ****Note.6| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%|
±3.0%| ±2.0%| ±2.0%| ±2.0%
SETUP, RISE, HOLD UP TIME| 1000ms, 30ms, 50ms/230VAC
1500ms, 30ms, 15ms/115VAC at full load
INPUT| VOLTAGE RANGE ****Note.7| 85 ~ 264VAC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 81%| 85%| 85%| 86%| 87%| 88%| 88%| 88.5%| 89%
AC CURRENT| 0.5A / 115VAC 0.3A / 230VAC
INRUSH CURRENT (max.)| Cold start 35A / 115VAC 65A /
230VAC
LEAKAGE CURRENT(max.)| 0.25mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE| 110 ~ 140% rated output voltage
Protection type: Clamp by Zener diode, output short
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating
Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC (Note. 8)| SAFETY STANDARDS|
UL62368-1, CSA C22.2 No.62368-1, BSMI CNS14336-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:4242VDC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level
/ Note**
Conducted emission| FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
CNS13438, EAC TP TC 020
| Class B
Radiated emission| FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
CNS13438, EAC TP TC 020
| Class B
OTHERS| MTBF| 3879.7K hrs min. Telcordia SR-332 (Bellcore);
668.4K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 795433mm (LWH)
PACKING| 198g; 60pcs/12.9Kg/1.15CUFT
CONNECTOR| PLUG| See page 4~5; Other type available by customer
requested
CABLE| See page 4~5; Other type available by customer requested
NOTE
| 1. All parameters are specified at 115VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measured by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μF & 47μF capacitor.
4. Tolerance: includes set up tolerance, line regulation, and load regulation.
5. Line regulation is measured from the low line to the high line at the rated load.
6. Load regulation is measured from 10% to 100% rated load.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The power supply is considered an independent unit, but the final equipment still needs to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Derating Curve
Static Characteristics
Mechanical Specification
DC output plug
- Standard plug: P1J
- DC plug changeable through:
1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
2. Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide below:
https://www.meanwell.com/upload/pdf/DC_plug.pdf.