MEAN WELL IRM-45-5ST AC DC Power Supply
Product Information
Specifications
- Product Name: 45W AC-DC PCB-Mount Green Power Module
- Series: IRM-45
- Compliance: UL62368-1, BS EN/EN62368-1, BS EN/EN60335-1, RoHS
- Size: 3.43” x 2.05” compact size
- Mounting Options: PCB, chassis, or screw terminal
- Input Voltage: Universal input 85~305VAC
- No Load Power Consumption
Product Usage Instructions
Mounting the Power Module
Depending on your application, you can mount the power module on a PCB,
chassis, or using screw terminals. Ensure proper insulation and secure
mounting for safety.
Connecting Power Input
Connect the universal input voltage of 85~305VAC to the designated input
terminals on the power module. Ensure correct polarity to prevent damage.
Powering Devices
After mounting and connecting the power input, you can now use the power
module to supply power to your devices within the specified power rating of
45W.
Frequently Asked Questions (FAQ)
-
Q: Can I use this power module for 5V devices?
A: The power module is not suitable for 5V devices as mentioned in the user manual. -
Q: What is the no-load power consumption of the module?
A: The power module has no-load power consumption, meaning it consumes minimal power when no load is connected.
Features
- 3.43″x2.05″ compact size
- PCB, chassis or screw terminal mounting version
- Universal input 85~305VAC
- No load power consumption<0.15W
- EMI Class B without additional components
- Wide operating temp. range -30~70°C
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Isolation Class II
- Overvoltage category Ill
- Pass LPS(Except for 5V)
- 3 years warranty
Applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Handheld electronic device
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
IRM-45 is a 45W miniature (875229.5mm) AC-DC module-type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipment. This product allows the universal input voltage range of 85~305VAC. The 94V-0 flame retardant plastic case and potted with silicone enhance heat dissipation. PCB mounting style model(Blank) meet the anti-vibration demand up to 2G and screw terminal style model (ST) meet the anti-vibration demand up to 5G; moreover, it provides fundamental resistance to dust and moisture.
With a high efficiency up to 90.5% and extremely low no-load power consumption below 0.15W, IRM-45 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class Il design (no FG pin), incorporating the built-in EMI filtering components, enabling compliance with BS EN/EN55032 Class B; the supreme EMC features keep the end electronic units from electromagnetic interference. In addition to the PCB mounting style model, IRM-45 series also offers the screw terminal style model (ST).
Model Encoding
SPECIFICATION
MODEL| IRM-45-5| IRM-45-12| IRM-45-15| IRM-45-24|
IRM-45-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 8A| 3.8A| 3A| 1.9A| 0.94A
CURRENT RANGE| 0 ~ 8A| 0 ~ 3.8A| 0 ~ 3A| 0 ~ 1.9A| 0 ~ 0.94A
RATED POWER| 40W| 45.6W| 45W| 45.6W| 45.12W
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 150mVp-p| 180mVp-p| 200mVp-p|
300mVp-p
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.5%| ±2.5%| ±2.5%| ±2.5%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 50ms/230VAC 12ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ~ 305VAC
FREQUENCY RANGE| 47 ~ 440Hz
EFFICIENCY (Typ.)| 83.5%| 87.5%| 88.5%| 89.5%| 90.5%
AC CURRENT (Typ.)| 1.5A/115VAC 0.9A/230VAC
0.75A/277VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT| < 0.25mA/277VAC
PROTECTION| **
OVERLOAD
| 115%~160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE
| 5.25 ~ 6.75V| 12.6 ~ 16.2V| 15.75 ~ 20.25V| 25.2 ~ 32.4V| 50.4 ~ 64.8V
Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION
| Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z
axes
ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering:
390℃,3s (max.)
OVER VOLTAGE CATEGORY| Ⅲ; According to EN62368-1;altitude up to 2000
meters
OPERATING ALTITUDE Note.4| 2000 meters
SAFETY & EMC
(Note.5)
| SAFETY STANDARDS| IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, BS
EN/EN60335-1, EAC TP TC 004, BSMI CNS14336-1 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32), CNS13438| Class B
Radiated| BS EN/EN55032(CISPR32), CNS13438| Class B
Harmonic Current (Note 5)| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, criteria A
Surge| BS EN/EN61000-4-5| Level 4, 2KV/L-N, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
>95% interruptions 250 periods
OTHERS| MTBF| 6451.1K hrs min. Telcordia SR-332 (Bellcore) ;
1212.1K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| PCB mounting style : 875229.5mm (LWH) Screw
terminal style : 1095233.5mm (LWH)
PACKING| PCB mounting style : 0.195Kg;60pcs/12.7Kg/0.94CUFT Screw
terminal style :0.228Kg; 50pcs/12.4Kg/0.56CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
5. The power supply is considered as an independent unit, but the final equipment still need to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx