MEAN WELL RPS-60 Series 60W Reliable Green Medical Power Supply Owner’s Manual
- August 14, 2024
- MEAN WELL
Table of Contents
MEAN WELL RPS-60 Series 60W Reliable Green Medical Power Supply
Product Information
Specifications
- Model: RPS-60 series
- Power Output: 60W
- Compliance: EN 60601-1 IEC 60601-1, ANSI/AAMI ES60601-1, BS EN/EN60601-1 IEC60601-1, UL62368-1, BS EN/EN62368-1 IEC62368-1
- Certifications: TPTC004
Features
The 60W Reliable Green Medical Power Supply offers the following features.
- Reliable performance
- Green technology
- Suitable for medical applications
Product Usage Instructions
Installation
- Ensure the power supply is compatible with your device.
- Connect the power supply to a suitable power outlet.
- Verify that the output voltage matches the requirements of your device.
Operation
- Turn on the power supply using the designated switch.
- Monitor the device connected to ensure proper functionality.
- Do not expose the power supply to water or extreme temperatures.
Maintenance
Regularly check the power supply for any signs of damage or wear. If any issues are detected, discontinue use and seek professional assistance.
FAQ
Q: Can this power supply be used with non-medical devices?
A: While designed for medical applications, it may be compatible with other devices that require similar power specifications. Always check compatibility before use.
Q: What should I do if the power supply overheats?
A: If the power supply overheats, immediately disconnect it from the power source and allow it to cool down before attempting to use it again. If the issue persists, contact customer support for further assistance.
Features
- 4″x2″ compact size
- IT & Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1, IEC/BS EN/EN60601-1, and IEC/BS EN/EN/UL 62368-1
- Suitable for BF application with appropriate system consideration
- Cooling by free air convection
- EMI Class B for class I configuration
- No load power consumption<0.75W
- Protections: Short circuit / Overload / Over voltage
- Operating altitude up to 3000 meters
- 3 years warranty
Applications
- Oral irrigator
- Hemodialysis machine
- Medical computer monitors
- Sleep apnea devices
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.asox
Description
- RPS-60 is a 60W highly reliable green PCB-type medical power supply with a high power density on the 4″ by 2″ footprint. It accepts 90~264VAC input and offers various output voltages between 3.3V and 48V.
- The working efficiency is up to 86% and the extremely low no-load power consumption is down below 0.75W. RPS-60 can be used for Class I (with FG) system design. The extremely low leakage current is less than 130M A.
- In addition, it conforms to international IT and medical regulations (2*MOPP) and EMC BS EN/EN55022/BS EN/EN55011, perfectly fitting all kinds of BF-rated “patient contact” medical system equipment.
Model Encoding
SPECIFICATION
MODEL| RPS-60-3.3| RPS-60-5| RPS-60-12| RPS-60-15|
RPS-60-24| RPS-60-48
---|---|---|---|---|---|---
**OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 10A| 10A| 5A| 4A| 2.5A| 1.25A
CURRENT RANGE| 0 ~ 11A| 0 ~ 11A| 0 ~ 5.5A| 0 ~ 4.4A| 0 ~ 2.75A| 0 ~
1.375A
RATED POWER| 33W| 50W| 60W| 60W| 60W| 60W
PEAK LOAD(10sec.) Note.2| 36.3W| 55W| 66W| 66W| 66W| 66W
RIPPLE & NOISE (max.) **Note.3| 60mVp-p| 60mVp-p| 60mVp-p| 100mVp-p|
100mVp-p| 100mVp-p
VOLTAGE ADJ. RANGE| 3.1 ~ 3.6V| 4.75 ~ 5.5V| 11.4 ~ 13.2V| 13.5 ~ 16.5V|
22.8 ~ 27.6V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.4| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 30ms/230VAC 500ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 60ms/230VAC 12ms/115VAC at full load
**INPUT| VOLTAGE RANGE| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 74%| 79%| 84%| 85%| 87%| 86%
AC CURRENT (Typ.)| 1.8A/115VAC 1 A/230VAC
INRUSH CURRENT (Typ.)| COLD START 60A/230VAC 30A/115VAC
LEAKAGE CURRENT(max.) Note.5| Earth leakage current < 130μA/264VAC ,
Touch current < 100μA/264VAC
****PROTECTION| ****OVERLOAD| 115 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
****OVERVOLTAGE**| 3.8 ~ 5V| 5.7 ~ 6.8V| 13.8 ~ 16.2V| 17.2 ~ 20.3V| 28.4
~ 32.4V| 55.2 ~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along
the X, Y, and Z axes
OPERATING ALTITUDE Note.6| 3000 meters
S AFETY & EMC
(Note 8)
| ****
SAFETY STANDARDS
| IEC 60601-1:2005+A1, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2,
CAN/CSA C22.2 No. 60601-1:2014+A2, IEC 62368-1:2014, UL 62368-1, 2nd Ed, CSA C22.2 No. 62368-1-14, 2nd Ed,
TUV BS EN/ EN 62368-1:2014+A11, EAC TP TC 004 approved
ISOLATION LEVEL| Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP,
Secondary-Earth:1xMOPP
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25℃/
70% RH
**EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55011 (CISPR11)| Class B
Radiated emission| BS EN/EN55011 (CISPR11)| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage flicker| BS EN/EN61000-3-3| —–
****EMC IMMUNITY| BS EN/EN55035 ,BS EN/EN60601-1-2
Parameter| Standard| Test Level / Note**
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, 10V
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, 30A/m
**** Voltage dip, interruption| BS EN/EN61000-4-11| 100% dip 1 period, 30%
dip 25 periods,
100% interruptions 250 periods
**OTHERS| MTBF| 5153.0K hrs min. Telcordia SR-332
(Bellcore); 353.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION (LWH)| 101.650.829mm or 4″ 2″ 1.141″ inch
PACKING| 0.15Kg; 96pcs/15.4Kg/0.89CUFT
****NOTE**| 1. All parameters NOT specially mentioned are measured at
230VAC input, rated load, and 25℃ of ambient temperature.
2. 33% Duty cycle maximum within every 30 seconds. The average output power should not exceed the rated power.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
4. Tolerance: includes set up tolerance, line regulation, and load regulation.
5. Touch current was measured from primary input to DC output.
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
7. Heat Sink HS1,HS2 can not be shorted.
8. The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
fosc : 100KHz
Output Derating
AMBIENT TEMPERATURE ( C)
Output Derating VS Input Voltage
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Unit:mm
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/N | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
2 | No Pin | ||
3 | AC/L |
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2 | +V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
3,4 | -V |
Grounding Required
- HS1, HS2 cannot be shorted.
- M1 is safety ground. For better EMC performance, Please secure an electrical connection between
- M1, M2, and chassis grounding.
Installation Manual
Please refer to: http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>