SPECIFICATION

MODEL| HLG-60H-15| HLG-60H-20| HLG-60H-24| HLG- 60H-30| HLG-60H-36| HLG-60H-42| HLG-60H-48| HLG-60H-54
---|---|---|---|---|---|---|---|---







OUTPUT

| DC VOLTAGE| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
CONSTANT CURRENT REGION Note.4| 9 ~ 15V| 12 ~ 20V| 14.4 ~ 24V| 18 ~ 30V| 21.6 ~ 36V| 25.2 ~ 42V| 28.8 ~ 48V| 32.4 ~ 54V
RATED CURRENT| 4A| 3A| 2.5A| 2A| 1.7A| 1.45A| 1.3A| 1.15A
RATED POWER| 60W| 60W| 60W| 60W| 61.2W| 60.9W| 62.4W| 62.1W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p| 300mVp-p| 300mVp-p| 300mVp-p
VOLTAGE ADJ. RANGE| Adjustable for A/AB-Type only (via built-in potentiometer)
13.5 ~ 17V| 17 ~ 22V| 22 ~ 27V| 27 ~ 33V| 33 ~ 40V| 40 ~ 46V| 44 ~ 53V| 49 ~ 58V
CURRENT ADJ. RANGE| Adjustable for A/AB-Type only (via built-in potentiometer)
2.4 ~ 4A| 1.8 ~ 3A| 1.5 ~ 2.5A| 1.2 ~ 2A| 1 ~ 1.7A| 0.87 ~ 1.45A| 0.78 ~ 1.3A| 0.69 ~ 1.15A
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.5%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| Note.6| 500ms,80ms/115VAC 500ms,80ms/230VAC
HOLD UP TIME (Typ.)**| 16ms / 115VAC, 230VAC







INPUT

| VOLTAGE RANGE| Note.5| 90 ~ 305VAC           127 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION| THD< 20% (@ load≧60% / 115VAC,230VAC; @ load≧75% / 277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)

EFFICIENCY (Typ.)| 87.5%| 89%| 89.5%| 90%| 90%| 90%| 90.5%| 90.5%
AC CURRENT (Typ.)| 0.64A / 115VAC           0.32A / 230VAC 0.3A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC



PROTECTION

| OVER CURRENT| Note.4| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 18 ~ 24V| 23 ~ 30V| 28 ~ 35V| 35 ~ 43V| 41 ~ 49V| 48 ~ 58V| 54 ~ 65V| 59 ~ 68V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover



ENVIRONMENT

| WORKING TEMP.| Tcase= -40 ~ +80℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase= +80℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes



SAFETY & EMC

| SAFETY STANDARDS Note.8| UL8750(type”HL”), CSA C22.2 No. 250.0-08, BS EN/EN/AS/NZS 61347-1,BS EN/EN/AS/NZS 61347-2-13 independent, GB19510.1,GB19510.14,EAC TP TC 004,KC61347-1,KC61347-2-13(except for AB-type), IP65 or IP67 approved ;

J61347-1, J61347-2-13 (except for B,AB and D-type) ; design refer to BS EN/EN60335-1(by request)

WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Note.8| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧60%) ; BS EN/EN61000-3-3,GB/T 17743 , GB17625.1, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV),EAC TP TC 020


OTHERS

| MTBF| 3396.9K hrs min.       Telcordia SR-332 (Bellcore) ;345.8K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 17161.536.8mm (LWH)
PACKING| 0.73Kg; 20pcs/15.6Kg/0.9CUFT
NOTE| 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  Please refer to “DRIVING METHODS OF LED MODULE”.

5.  De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

6.  Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7.  The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

8.  To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.

9.  This series meets the typical life expectancy of >62,000 hours of operation when Tcase,  particularly tc point (or TMP, per DLC), is about 70℃ or less.

10.  Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com.

11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

12.  For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Product Usage Instructions

Installation

  1. Ensure the input voltage matches the specified range.
  2. Connect the output wires to the LED lights as per the required voltage and current.
  3. Mount the LED driver in a well-ventilated area away from moisture.

Adjusting Voltage and Current
For A/AB-Type models, use the built-in potentiometer to adjust the voltage and current within the specified ranges.

Powering On

  1. After installation, connect the LED driver to the power source.
  2. Switch on the power and ensure proper functionality of the LED lights.

Maintenance
Regularly check for any signs of damage or overheating. Clean the driver as needed to prevent dust accumulation.

Features

  • Constant Voltage + Constant Current mode output
  • Metal housing with class 1 design
  • Built-in active PFC function
  • Class 2 power unit
  • IP67 / 1P65 rating for indoor or outdoor installations
  • Function options: output adjustable via potentiometer; 3 in 1 dimming; Timer dimming
  • Typical lifetime > 62000 hours
  • 7 years warranty

Applications

  • LED street lighting
  • LED high-bay lighting
  • Parking space lighting
  • LED fishing lamp
  • LED greenhouse lighting
  • Type “HL” for use in Class I , Division 2 hazardous (Classified) location.

GTIN CODE
MW Search : https://www.meanwell.com/serviceGTIN.aspx

Description
HLG-60H series is a 60W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-60H operates from 90 ~ 305VAC and offers models with different rated voltage ranging between 15V and 54V. Thanks to the high efficiency up to 90.5%, with the fanless design, the entire series is able to operate for -40°C ~ +80°C case temperature under free air convection. The design of metal housing and IP67/1P65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-60H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.

Model Encoding

Type IP Level Function Note
Blank IP67 Io and Vo fixed In Stock
A IP65 Io and Vo adjustable through built-in potentiometer In Stock
B IP67 3 in 1 dimming function (1~10VDC, 10V PWM signal and resistance) In

Stock
AB| IP65| Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (1~10Vdc, 10V PWM signal and resistance)| In Stock
D| IP67| Timer dimming function, contact MEAN WELL for details (safety pending).| By request

BLOCK DIAGRAM

DRIVING METHODS OF LED MODULE

※ This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.

Typical output current normalized by rated current (%)

DIMMING OPERATION

3 in 1 dimming function (for B/AB-Type)

  • Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 1 ~ 10VDC, or 10V PWM signal or resistance.
  • Direct connecting to LEDs is suggested. It is not suitable ‧ to be used with additional drivers.
  • Dimming source current from power supply: 100μA (typ.)

Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL for other options.

Using a switch and relay can turn ON/OFF the lighting fixture.

OUTPUT LOAD vs TEMPERATURE(Note.10)

STATIC CHARACTERISTICS

De-rating is needed under low input voltage.

POWER FACTOR(PF) CHARACTERISTIC

TOTAL HARMONIC DISTORTION (THD)

  • 48V Model, Tcase at 70℃

EFFICIENCY vs LOAD

HLG-60H series possess superior working efficiency that up to 90.5% can be reached in field applications.

  • 48V Model, Tcase at 70℃

LIFETIME

MECHANICAL SPECIFICATION

Blank/D-Type

A-Type

B-Type

AB-Type

WATERPROOF CONNECTION

Waterproof connector
The waterproof connector can be assembled on the output cable of HLG-60H to operate in dry/wet/damp or outdoor environment

INSTALLATION MANUAL

Please refer to: http://www.meanwell.com/manual.html

FAQ’S

Q: Can I use this LED driver with outdoor lighting?
A: Yes, this LED driver is rated IP65/IP67 for outdoor use, providing protection against dust and water.

Q: How many LED lights can I connect to this driver?
A: The maximum number of units that can be connected depends on the circuit breaker type and voltage.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals