luminii PDCU-D-30-24,PDCU-D-60-24 Pure DC Universal Power Supply Installation Guide

August 11, 2024
luminii

luminii PDCU-D-30-24,PDCU-D-60-24 Pure DC Universal Power Supply

Specifications

Models MAX Load A. Length B. Width C. Depth Net Weight
PDCU-D-30-24 30 watts 6.10″ 3.35″ 1.32″ 2.2 lbs
PDCU-D-60-24 60 watts 7.93″ 3.35″ 1.32″ 1.5 lbs

Product Usage Instructions

  1. Mounting:
    The power supply can be mounted vertically or horizontally with a minimum of 2-inch clearance around the power supply to ensure proper air circulation.

  2. Opening the Driver Housing:
    Remove the two Phillips screws from the top of the driver housing and pull the cover off to expose the driver wires.

  3. Wiring Connections:
    Insert the 120-277 VAC power into the driver housing from th electrical panel. Bring the 24V DC low voltage wires from the LED into the driver housing. Ensure proper wiring connections as per the diagram provided.

  4. Dimmer Connections (if applicable):
    If using a 0-10V Dimmer, connect according to the provided instructions. Make sure to connect the wires properly and securely.

  5. Closing the Driver Housing:
    Insert the wire nut connections in the driver housing and close the housing cover. Secure by tightening the two screws.

FAQ:
Q: Can I install the power supply myself?
A: No, the power supply should only be installed by a qualified electrician due to being hardwired and requiring compliance with electrical codes.

PDCU-D Pure DC® Universal Power Supply – Installation Instructions

Models PDCU-D-30-24 & PDCU-D-60-24

Please read all instructions prior to installation and keep for future reference!
This power supply is to be installed in accordance with Article 450 of the National Electrical Code. The power supply must be installed in a well ventilated area and free from explosive gasses and vapors. Proper operation requires the free flow of air. As this power supply is hardwired, it should only be installed by a qualified electrician. UL class 2 recognized

MODELS PDCU-D-30-24 PDCU-D-60-24
MAX Load 30 watts 60 watts
A. Length 6.10” 7.93”
B. Width 3.35” 3.35”
C. Depth 1.32” 1.32”
Net Weight 2.2 lbs 1.5 lbs
  1. Before installing, check the label and ensure the power supply has the proper input voltage, output voltage, and wattage for the job. Check the wire markings to ensure they match the wiring diagram below. Refer to table above for the maximum loads!

  2. Power supply can be mounted vertically or horizontally. With a minimum of 2” clearance around power supply to provide proper air circulation.

  3. Remove the two Phillips screws from the top of the driver housing and pull the cover off to expose the driver wires.

  4. Insert the 120-277 VAC power into the driver housing from the electrical panel. Followed by bringing the 24V DC low voltage wires from the LEDs into the driver housing. In addition bring the controller wire if applicable. Refer to diagram on page 2 to make all the proper wiring connections.

  5. WIRING DIAGRAMluminii PDCU-D-30-24,PDCU-D-60-Pure-DC-Universal-Power-Supply- \(6\)

  6. Insert the wrie nut connections in the driver housing and close housing cover. Secure by tightening the two screws.

*LUMINAIRE RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE