Mean Well NTU-1200 series High Reliable True Sine Wave with UPS DC-AC Power Inverter Installation Guide
- August 9, 2024
- MEAN WELL
Table of Contents
Mean Well NTU-1200 series High Reliable True Sine Wave with UPS DC-AC
Power Inverter
Features
- Built-in UPS function (AC by-pass)
- True sine wave output (THD<3%)
- High surge power up to 2000W
- Temperature-controlled cooling fan
- AC output voltage and frequency selectable by DIP S.W
- -25°C~+70°C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections : Input: Reverse polarity / DC low alarm / DC low shutdown / Over voltage Output: Short circuit / Overload / Over temp.
- Battery over-discharge protection (low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Remote controller (IRC1, IRC2, IRC3 accessory sold separately, please refer to: hitts://www.meanwell.com/webapp/product/search.aspx?prod= RC1 )
- Support RS-232 communication(Communication cable order No.: RJ11-RS232, sold separately)
- Carry handle accessory available(Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
NTU-1200 is a 1200W highly reliable off-grid true sine wave DC-AC power inverter with a built-in UPS function(AC by-pass). Its key features include digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high-quality fan with low acoustic noise, 2000W peak power, adjustable AC output voltage, and frequency, -25~+70°C wide operating temperature range, complete protection features, etc. Combined with batteries, the NTU-1200 is suitable for use in residential, commercial, marine, automobile, mine, construction sites, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, induction stove, air conditioner, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, etc.
Model Encoding
SPECIFICATION
MODEL NO.
| NTU-1200-112| NTU-1200-124| NTU-1200-148| NTU-1200-212|
NTU-1200-224| NTU-1200-248
---|---|---|---|---|---|---
= US, GFCI, UN| = EU, CN, AU, UK, UN
AC OUTPUT
| RATED POWER(Continuous)| 1200W
OVERRATED POWER(3 Min.)| 1380W
PEAK POWER(10 Sec.)| 1800W
SURGE POWER(30 Cycles)| 2000W
AC VOLTAGE| The default setting set at 110VAC| The default setting set
at 230VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W| 200 / 220 / 230 / 240Vac
selectable by DIP S.W
FREQUENCY| The default setting set at 60±0.1Hz| The default setting set
at 50±0.1Hz
50/60Hz selectable by DIP S.W| 50/60Hz selectable by DIP S.W
WAVEFORM **Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated output voltage
FRONT PANEL LED**| Please see page 5
DC INPUT
| DC VOLTAGE| 12Vdc| 24Vdc| 48Vdc| 12Vdc| 24Vdc| 48Vdc
VOLTAGE RANGE (Typ.)| 10 ~ 16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc| 10 ~
16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc
DC CURRENT (Typ.)| 120A| 60A| 30A| 120A| 60A| 30A
NO LOAD DISSIPATION
(Typ.)
| NON-SAVING MODE| 15W| 25W
SAVING MODE| Default disable, auto-detect AC output load≦10W will be
changed to saving mode
<8W
OFF-MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.) Note.1| 89%| 90%| 91%| 90%| 92%| 93%
BATTERY TYPES| Lead Acid or li-ion
PROTECTION| DC INPUT| FUSE (INTERNAL)| 40A4| 40A2| 25A2|
40A4| 40A2| 25A2
LOW
| ALARM| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc
SHUTDOWN| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc
RESTART| 12.5±0.3Vdc| 25±0.5Vdc| 50±1Vdc| 12.5±0.3Vdc| 25±0.5Vdc|
50±1Vdc
HIGH
| ALARM| 15.5±0.3Vdc| 31±0.5Vdc| 62±1Vdc| 15.5±0.3Vdc| 31±0.5Vdc|
62±1Vdc
SHUTDOWN| 16.5±0.3Vdc| 33±0.5Vdc| 66±1Vdc| 16.5±0.3Vdc| 33±0.5Vdc|
66±1Vdc
RESTART| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc
BAT. POLARITY| By internal fuse open
AC OUTPUT| OVER TEMPERATURE| Protection type: Shut down o/p
voltage, re-power on to recover
OUTPUT SHORT| Protection type: Shut down o/p voltage, re-power on to
recover
OVERLOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10
sec.
Protection type: Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER| 15A| 10A
GFCI PROTECTION| UL458 (Only for “GFCI” AC socket, by request)| None
FUNCTION
| REMOTE CONTROL| CONNECTOR| Power ON-OFF remote control by
front panel dry contact connector(by RELAY), Open: Normal work; Short: Remote
off
ACCESSORY| Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
RS-232 COMMUNICATION| RS-232 ~ RJ11 Type connector (Please refer to page
4 for more details)
AC UPS MODE| AC INPUT RANGE| 100/110/115/120Vac±16%, recover±13%|
200/220/230/240Vac±16%, recover±13%
FREQUENCY RANGE| 45 ~ 65Hz
TRANSFER TIME(Typ.)| 10ms inverter AC bypass
ENVIRONMENT
| WORKING TEMP.| -25 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-
condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, and Z
axes
SAFETY
& EMC
(Note.4)
| SAFETY STANDARDS| CB IEC62368-1,Dekra BS EN/EN62368-1,UL458, E13,EAC TP TC 004 approved; Design refer to AS/NZS 62368.1
(Please refer to the next page“AC output socket” table for more details)
WITHSTAND VOLTAGE| DC I/P – AC I/P:3.0KVac DC I/P – AC O/P:3.0KVac AC O/P – FG:1.5KVac
EMC EMISSION
| Parameter| Standard| Test Level / Note
Radiated| FCC for 112,124,148 only(expect for Type-UN)| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)| Class A
Conducted| FCC for 112,124,148 only(expect for Type-UN)| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)| Class A
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
END| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 1
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 460.5K hrs min. Telcordia TR/SR-332 (Bellcore); 58.3K
hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 33318470mm (LWH)
PACKING| 3.3Kg; 2pcs/ 7.6Kg/ 1.25CUFT
NOTE
|
- Efficiency, AC regulation, and THD are tested by 900W load, linear load at 12.5 Vdc/25 Vdc/50 Vdc input voltage.
- All parameters not specified above are measured at rated load, 25°C of ambient temperature, and set to factory setting.
- Internal pre-start circuit, the setup time is 8s.
- The power supply is considered as andependent unit, but the final equipment still needs to reconfirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on https://www.meanwell.com//Upload/PDF/EMI_statement__en.pdf )
- Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
AC Output Socket
DERATING CURVE
IRC1/2/3 Remote Controller (Accessory sold seperately)
- IRC1/IRC2/IRC3 is the monitoring and control unit.
- IRC1/IRC2/IRC3 can decode the RS-232 signals sent by the inverter series and display them through digital meters.
Note: Part of the control signals will not function properly due to different compliance of each model.
- Please refer to for more details: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1
Support RS-232 Communication
- The internal data of a single NTU-1200 can be read through RS-232.
- Please refer to for more details: http://www.meanwell.com/manual.html
- RJ11-RS232 Communication cable should be ordered seperately, Order No.: RJ11-RS232
Remote ON-OFF Control (Built-in)
- Remote ON-OFF AC Output Status
- Open power inverter ON
- Short power inverter OFF
AC Output Voltage, Frequency, and Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz
or 230Vac/50Hz, users can adjust the voltage and frequency, through the DIP
switch of position 1,2,3,4 on the panel.
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW1| SW2| SW3| SW4
OFF| OFF :| 100Vac or 200Vac|
ON: 50Hz
|
ON: Saving mode
OFF| ON :| 110Vac or 220Vac
ON| OFF :| 115Vac or 230Vac|
OFF: 60Hz
| OFF: Non-Saving mode
ON| ON :| 120Vac or 240Vac
LED STATUS
Normal work:
Abnormal status
MECHANICAL SPECIFICATION
Accessory List
- Communication cable (Optional accessory, Power inverter, and Communication cable should be ordered seperately)
- Carry handle (Optional accessory, Power inverter, and Pull handle should ordered seperately)
TYPICAL APPLICATION
-
Battery Bank
-
Off-Grid DC/AC Solar Inverter (NTU series)
-
AC Outlet
-
1 Utility Input (Shore)
-
AC/DC Battery Charger (PB/NPB/NPP series)
-
Battery Bank
-
Off-Grid DC/AC Power Inverter (NTU series)
-
AC Outlet
-
AC/DC Battery Charger (PB/NPB/NPP series)
-
Battery Bank
-
Off-Grid DC/AC Inverter (NTU series)
-
AC Outlet
INSTALLATION MANUAL
- Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>