MEAN WELL LCM-25DA Series 25W Multiple Stage Constant Current Mode LED Driver Owner’s Manual
- August 5, 2024
- MEAN WELL
Table of Contents
MEAN WELL LCM-25DA Series 25W Multiple Stage Constant Current Mode LED
Driver
FAQ
Frequently Asked Questions
- Q: How do I know which current level to select?
- A: The current level selection should be based on the requirements of your LED setup. Consult with a professional if unsure.
- Q: What should I do if the LED driver does not power up?
- A: Check the input power connections and ensure they are correct. If the issue persists, contact customer support for assistance.
- Q: Can I connect multiple LED drivers to a single circuit breaker?
- A: The maximum number of units that can be connected to a circuit breaker is specified in the manual. Do not exceed this limit to avoid overloading the circuit.
Features
- Constant Current mode output with multiple levels selectable by dip switch
- Emergency lighting application is available according to IEC61347-2-13
- Built-in active PFC function and class Il design
- Standby power consumption <0.5W
- Functions: DALI interface(logarithm or linear dimming curve selectable), push dimming synchronization up to 1 0units
- 3 years warranty
Applications
- LED indoor lighting
- LED office lighting
- LED commercial lighting
- LED panel lighting
- Industrial lighting
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
LCM-25DA series is a 25W AC/DC constant current mode output LED driver featuring the multiple levels selectable by dip switch and the DALI interface with the compliance to IEC62386. LCM-25DA operates from 180~277VAC and offers different current levels ranging between 350mA and 1050mA. Thanks to the efficiency up to 86%, with the fanless design, the entire series is able to operate for -30°C~+85°C case temperature under free air convection. In addition, LCM-25DA is equipped with push dimming and synchronization functions, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
SPECIFICATION
MODEL | LCM- 25 |
---|
OUTPUT
| ****
CURRENT LEVEL
| Current level selectable via DIP switch, please refer to”DIP SWITCH TABLE”
section
350mA| 500mA| 600mA| 700mA(default)| 900mA| 1050mA
RATED POWER| 18.9W| 25.2W
DC VOLTAGE RANGE| 6 ~ 54V| 6 ~ 50V| 6 ~ 42V| 6 ~ 36V| 6 ~ 28V| 6 ~ 24V
OPEN CIRCUIT VOLTAGE (max.)| 59V| 41V
CURRENT RIPPLE| 5.0% max. @rated current
CURRENT TOLERANCE| ±5%
SETUP TIME Note.3
Note.8
| 500ms / 230VAC
INPUT
| VOLTAGE RANGE Note.2| 180 ~ 277VAC 254 ~ 380VDC(254~375VDC for DA2-Type)
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.94/230VAC, PF≧0.91/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@load≧50%/230VAC;
@load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.) Note.4| 86%
AC CURRENT (Typ.)| 0.17A/230VAC 0.15A/277VAC
INRUSH CURRENT (Typ.)| COLD START 20A(twidth=260μs measured at 50%
Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| ****
26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.5mA / 240VAC
STANDBY POWER CONSUMPTION Note.5| <0.5W
PROTECTION| SHORT CIRCUIT| Constant current limiting, recovers
automatically after fault condition is removed
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| DIMMING| Please refer to “DIMMING OPERATION” section
SYNCHRONIZATION| Please refer to “SYNCHRONIZATION OPERATION” section
ENVIRONMENT
| WORKING TEMP.| Tcase=-30 ~ +85℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
| ****
SAFETY STANDARDS
| UL8750(except for DA2-Type), CSA C22.2 NO.250.0-08, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384
independent,GB19510.14,GB19510.1,BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to BS EN/EN61347-2-13 appendix J suitable for emergency installations(EL)(AC Input: 200-240Vac)(for DA2-Type only)
DALI STANDARDS| IEC62386-101, 102, 207,251
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC ; I/P-DA:1.5KVAC ; O/P-DA:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Note.6| Compliance to BS EN/EN55015, BS EN/EN61000-3-2
Class C(@load≧50%) ; BS EN/EN61000-3-3; GB/T 17743, GB17625.1, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020
OTHERS
| MTBF| 2661.8K hrs min. Telcordia SR-332 (Bellcore) ; 213.3K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1056823mm (LWH)
PACKING| 0.17Kg ; 72pcs/13.2Kg/1.04CUFT
NOTE|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
-
De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
-
Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
-
Efficiency is measured at 500mA/50V output set by DIP switch.
-
Standby power consumption is measured at 230VAC.
-
The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) -
The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
-
Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI power on function, otherwise the set up time will be higher than 0.5 second for DA2-type.
-
To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
- PFC fosc: 45KHz
- PWM fosc: 70KHz
DIP SWITCH TABLE
LCM-25DA/DA2 is a multiple-stage constant current driver, selection of output current through DIP switch is exhibited below.
Io / DIP S.W. | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
350mA | —- | —- | —- | —- | —- | —- |
500mA | ON | —- | —- | —- | —- | —- |
600mA | ON | ON | —- | —- | —- | —- |
700mA(factory default) | ON | ON | ON | —- | —- | ON |
900mA | ON | ON | ON | ON | —- | ON |
1050mA | ON | ON | ON | ON | ON | ON |
Note: For more current setting,please contact MW’s sales.
DIMMING OPERATION
PUSH dimming(primary side)
Action | Action duration | Function |
---|---|---|
Short push | 0.1~1 sec. | Turn ON-OFF the driver |
Long push | 1.5~10 sec. | Every Long Push changes the dimming direction, dimming |
up or down
Reset| >11 sec.| Set up the dimming level to 100%
- The factory default dimming level is at 100%.
- If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
- Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
- The maximum length of the cable from the push button to the last driver is 20 meters.
- The additive push button can be connected only between the PUSH terminal, as displayed in the diagram, and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N.
DALI interface(primary side; for DA/DA2-Type)
- Apply DALI signal between DA+ and DA-
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 6% of output.
SYNCHRONIZATION OPERATION
-
Synchronization up to 10 drivers (1 master + 9 slaves)
-
Dimming operating range: 10%~100%
-
Sync cable length: < 5m
-
Sync cable type: Flat cable
-
Sync cable cross section area: 22 – 24 AWG (0.2~0.3mm*)
-
CN100, CN101: used to synchronously control the LCM units in parallel.
NOTE
- Please make sure all units are set to 100% dimming setting (factory default) before synchronizing.
- Min. Dimming operating range depends on dimmer setting.
MORE INFORMATION
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
- De-rating is needed under low input voltage.
TOTAL HARMONIC DISTORTION (THD)
Tcase at 75°C
POWER FACTOR (PF) CHARACTERISTIC
Tcase at 75°C
EFFICIENCY vs LOAD
LCM-25DA series possess superior working efficiency that up to 86% can be reached in field applications.
Tcase at 75°C
MECHANICAL SPECIFICATION
- Case No. LCM-25
- Unit: mm
Terminal Pin No. Assianment(TB1YLCM-25DA)
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4 | DA+ |
2 | AC/N | 5 | DA- |
3 | PUSH |
Terminal Pin No. Assignment(TB1)(LCM-25DA2)
Pin No. | Assignment |
---|---|
1 | AC/L |
2 | AC/N |
3 | DA- |
4 | DA+ |
--- | --- |
Terminal Pin No. Assignment(TB2)
Pin No. | Assignment |
---|---|
1 | +V |
2 | -V |
SYN. Connector(CN100/CN101): JST B2B-PH-KL or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | – | JST PHR-2 or equivalent | |
2 | + |
Bottom View
- tc: Max. Case Temperature
Note: Please use wires with a cross section of 0.5~2.5mm (14~20AWG) for
TB1 and wires with a cross section of 0.5~1.5 mm'(16~20AWG) for TB2
Please use wires with a cross section of 0.126~0.205mm (24~26AWG) for
CN100/CN101
INSTALLATION MANUAL
- Please refer to: http://www.meanwell.com/manual.html
User’s Manual
Documents / Resources
| MEAN
WELL LCM-25DA Series 25W Multiple Stage Constant Current Mode LED
Driver
[pdf] Owner's Manual
LCM-25DA Series, LCM-25DA Series 25W Multiple Stage Constant Current Mode LED
Driver, 25W Multiple Stage Constant Current Mode LED Driver, Multiple Stage
Constant Current Mode LED Driver, Stage Constant Current Mode LED Driver,
Current Mode LED Driver, LED Driver, Driver
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>