esse 7IS-80598 Alarm System Elevators Compliant User Guide

July 30, 2024
ESSE

esse 7IS-80598 Alarm System Elevators Compliant

Product Specifications

  • Compliance: European Standard EN 81-28:2018
  • Model: Helpy Super Compact
  • Designed for: Retrofitting behind elevator car panel
  • Features:
    • Built-in loudspeaker
    • Alarm indicator light
    • Built-in microphone
    • Received alarm indicator light
    • Device status LED
    • USB-C port for PC connection
    • Reset pushbutton
    • Connectors T1, T2, T3 for various connections

Product Usage Instructions

Programming Modes

  • Local programming via e-stant GO app: Use a smartphone with the e-stant GO app through Bluetooth.
  • Local programming via e-stant software: Connect to a computer using a USB-C cable and the e-stant software for firmware updates and customization.
  • Remote programming: Program the device remotely via telephone using DTMF tones.

Minimum Operations to Verify Proper Installation

  1. Programming:
    • Program emergency-call alarm number
    • Record specific elevator identification message
    • Check PSTN line or universal gateway functionality
  2. Testing the Alarm Procedure: Press emergency call button for more than 3 seconds to initiate the alarm.
  3. Answering the Alarm:
    • 1st Mode: Two-way communication after voice messages
    • 2nd Mode: Two-way communication after input of activation code
    • 3rd Mode: Immediate two-way communication without messages
  4. Resetting the Alarm: Reset the alarm mode as needed.

Frequently Asked Questions (FAQ)

  • Q: How do I update the firmware of Helpy Super Compact?
    A: You can update the firmware using the e-stant software with a computer connected via USB-C cable.

  • Q: Can I customize the messages of Helpy Super Compact?
    A: Yes, you can customize messages using the e-stant software available for download.

  • Q: What is the factory default time to press the emergency call button for initiating the alarm?
    A: The factory default time is more than 3 seconds.

Alarm system for elevators compliant with the European Standard EN 81-28:2018

HELPY SUPER COMPACT
QUICK GUIDE

DESCRIPTION

Autodialer specifically designed for retrofitting behind the elevator car panel.

  • A Built-in loudspeaker
  • B Given alarm indicator light
  • C Built-in microphone
  • D Received alarm indicator light
  • E Device status LED
  • F USB-C port for PC connection
  • G Reset pushbutton
  • T1 Connector for telephone line and pushbutton
  • T2 Power supply connector
  • T3 Connector for induction loop amplifier and microphone cable

T1
p in 1 LTI PSTN-line or universal gateway input (2G/3G/4G)
p in 2 LTI PSTN-line or universal gateway input (2G/3G/4G)
p in 3 AL1 Alarm input
p in 4 C1 Common terminal for input AL1

T2
p in 1 + Power supply input (10 Vdc – 30 Vdc)
p in 2 — Negative

T3
p in 1 AM+ Output for connecting the induction loop amplifier unit (IN+)
pin 2 AM- Output for connecting the induction loop amplifier unit (IN-) / Negative for microphone cable
p in 3 MIC2 Input for connecting a microphone cable

PROGRAMMING MODES

Local programming via e-stant GO app
You can program Helpy Super Compact with a smartphone, via Bluetooth, by using the e-stant GO app. e-stant GO can be downloaded from an official store (Google Play or App Store).

Local programming via e-stant software
You can program Helpy Super Compact with a computer by using an USB-C cable and the dedicated e-stant software. e-stant software also allows to:

  • update the firmware of the Helpy Super Compact
  • customize the messages of the Helpy Super Compact.

e-stant can be downloaded at the following link: https://esse- ti.it/software/e-stant/

Remote programming
You can program Helpy Super Compact remotely by telephone (using DTMF tones).

MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION

  1. PROGRAMMING

    • Using one of the programming modes indicated above:
    • program a telephone number for the emergency-call alarm
    • if required, record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location.
    • Check the PSTN line or the universal gateway is properly working.
  2. TESTING THE ALARM PROCEDURE

    • Press the emergency call button for more than 3 seconds (factory value).
      The alarm starts.
  3. ANSWERING THE ALARM
    Note : the activation mode of the communication with the trapped person can be configured with the “Two-way communication mode during an alarm” programming (code 78).
    -1st mode: automatic two-way communication established after messages (factory default)

    • Answer by the called party.
      The two-way communication mode will be activated after the voice messages.

    • Speak with the trapped person.

    • -2nd mode: two-way communication established after input of “Communication activation” code

    • Answer by the called party.

    • The voice messages will be heard.

    • Press  0 to speak with the trapped person.
      -3rd mode: immediate and automatic two-way communication (no messages)

    • Answer by the called party.

    • Speak with the trapped person.

  4. RESETTING THE ALARM
    Note : the alarm reset mode can be configured with the “Alarm reset mode” programming (code 77).
    -1st mode: reset by “End” code (factory default)

    • Press 9 to end the alarm.
      -2nd mode: automatic reset
    • Hang up (or press  9 ) to end the alarm.

Note: in case it should not be possible to stop the alarm procedure remotely (i.e. the entered telephone number is incorrect) press the reset pushbutton.

USING THE RESET BUTTON

Note: the reset operation does not alter the previously set parameters.
Use of the reset pushbutton (G in the picture at page 2):

  • Pressing shortly
  • Allows to interrupt an alarm call.
  • Pressing longer (10 seconds)
  • Allows to reset the device.
  • By pressing longer, the Helpy Super Compact will be re-started with no need to disconnect the power supply.

Note: it is also possible to reset the device through the code 995*0#.

REMOTE PROGRAMMING

  • Call Helpy Super Compact (at rest) and wait for a response.
  • Listen to the elevator identification message, if present.
  • Dial to speak with the speaker unit.  or
  • Dial ) to access programming.

Basic programming

In the tables below:

  • INST indicates that the programming is allowed for the installer
  • OPER indicates that the programming is allowed by the maintenance technician
  • factory default values are highlighted in bold

Advanced programming

SIGNALS

Device status LED
Normal operation (no alarm)

Given alarm indicator light (yellow)

Received alarm indicator light (green)

Missed test call notification (EN 81-28:2018)
The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call.
The flashing sequence ends after the next successful test call or emergency call.

EU DECLARATION OF CONFORMITY

Hereby, Esse-ti S.r.l. declares that the equipment type Helpy Super Compact is in compliance with Directives 2014/30/EU – 2014/33/EU – 2014/35/EU.
The full text of the EU declaration of conformity is available from the following Internet address: https://esse-ti.it/dichiarazioni-di-conformita

Esse-ti S.r.l.
Via G. Capodaglio, 9
62019 Recanati (MC) – ITALY +39 071 7506066
www.esse-ti.it
support@esse-ti.it

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals