esse-ti ETMA Schindler Retrofit Kit Instruction Manual

June 13, 2024
esse-ti

RETROFIT KIT
SCHINDLER
10-24 Vdc

– ETMA
– TAM2
7IS-80590 29/09/2023

COMPONENTS

esse-ti ETMA Schindler Retrofit Kit - COMPONENTS

ETMA INSTALLATION

esse-ti ETMA Schindler Retrofit Kit - COMPONENTS

  1. Open the panel located at the highest landing floor. ETMA-MR is placed at the center of the panel.esse-ti ETMA Schindler Retrofit Kit - ETMA1

  2. Disconnect the X1-1-1 and X1-1-2 cables from ETMA-MR (X1-1-1 connects ETMA-MR to the ETMA-CAR located on the car roof or to the board located in the COP; X1-1-2 connects ETMA-MR to the telephone line).esse-ti ETMA Schindler Retrofit Kit - ETMA2

    1. On the car roof, open the panel located under the service buttons. ETMA-CAR is highlighted by the white arrow.esse-ti ETMA Schindler Retrofit Kit - ETMA3OR if the ETMA-CAR is not located on the car roof
    1. Disconnect the cables
      X1-1-2: link to ETMA-MR
      X1-1-6: power supply and LEDs
      X1-1-1: pushbutton normally closed.esse-ti ETMA Schindler Retrofit Kit -
ETMA43.2) Open the Car Operating Panel (COP) and lower the cable of the retrofit kit (5KT-134) from the car top.
      4.2) Disconnect the cables: CAR. ALARM: pushbutton normally closed
      CAR. POWER: power supply and LEDs
      LINK: link to ETMA-MR.esse-ti ETMA Schindler Retrofit Kit -
ETMA5
  3. Connect the cables to the corresponding cables of the retrofit kit (5KT-134), as shown in the picture.

  4. Connect a telephone to the terminal blocks of the retrofit kit (terminals TEL and –).
    . Connect the terminal blocks of the retrofit kit to the Helpy Compact Basic Retrofit.
    . Helpy Compact Basic Retrofit will turn on.
    . If an alarm starts lift the telephone handset and dial 0# (to reset the alarm), 0# (to enter programming mode) and 4101 (to set the AL1 input as normally closed).
    . Helpy Compact Basic Retrofit can be installed in place of the ETMA-CAR.
    . Please make sure the microphone is placed in correspondence with a car hole and the audio quality is good.
    . In any case Helpy Compact Basic Retrofit can be installed facing upwards .esse-ti ETMA Schindler Retrofit Kit - ETMA6

  5. Connect the
    X1-1-1 and X1-1-2 cables, disconnected from the ETMA-RM, together.

Note: for basic programming see the table in the last page.

TAM2 INSTALLATION

esse-ti ETMA Schindler Retrofit Kit - ETMA7

  1. On the car roof, open the panel located under the service buttons.
    TAM2 is highlighted by the white arrow.esse-ti ETMA Schindler Retrofit Kit -
ETMA8

  2. Disconnect the cables
    X1-1-2: telephone line
    X1-1-6: power supply and LEDs
    X1-1-1: pushbutton normally closed.esse-ti ETMA Schindler Retrofit Kit -
ETMA9

  3. Connect the cables to the corresponding cables of the retrofit kit (5KT-134), as shown in the picture.

  4. Connect a telephone to the terminal blocks of the retrofit kit (terminals TEL and –).
    .Connect the terminal blocks of the retrofit kit to the Helpy Compact Basic Retrofit.
    . Helpy Compact Basic Retrofit will turn on.
    . If Helpy Compact Basic Retrofit doesn’t turn on, you should use the universal power supply ST-Power 12V (5HA-005), see the next page.
    . If an alarm starts lift the telephone handset and dial 0# (to reset the alarm), 0# (to enter programming mode) and 4101 (to set the AL1 input as normally closed).
    . Helpy Compact Basic Retrofit can be installed in place of the TAM2.
    . Please make sure the microphone is placed in correspondence with a car hole and the audio quality is good.
    . In any case Helpy Compact Basic Retrofit can be installed facing upwards.

Note: for basic programming see the table in the last page.

UNIVERSAL POWER SUPPLY ST-POWER 12V

  1. Connect the universal power supply ST-Power 12V (5HA-005) to the Helpy Compact Basic Retrofit by means of the 12 Vdc terminal (B in the figure).
  2. Connect a 12 V 1,3 Ah battery to the universal power supply ST-Power 12V by means of the two faston cables (it is necessary to open the cover by removing the fixing screw).
  3. Connect the 100-240 Vac mains voltage cable by means of N and L terminals (A in the figure).

BASIC PROGRAMMING

 Access to programming *0#
1st telephone number for emergency call 210112#
2nd telephone number for emergency call 210212#
3rd telephone number for emergency call 210312#
 telephone number for periodic test call (CLI mode) 210434#
Record identification message 7101hang up>
Listen to identification message 7201
 Emergency call button delay 42X (X=3-9 secondi/seconds)
 Emergency input AU normally closed/open 4101 normally closed

4111 normally open
Exiting the programming| *0#

Esse-ti S.r.l.
Via G. Capodaglio, 9
62019 Recanati (MC) – ITALY
Tel. +39 071 7506066
www.esse-ti.it
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

esse-ti User Manuals

Related Manuals