esse-ti 5HK-300 Kone Retrofit Kit Instruction Manual
- June 4, 2024
- esse-ti
Table of Contents
esse-ti 5HK-300 Kone Retrofit Kit
COMPONENTS
KRM INSTALLATION
- Unscrew the 4 screws (shown in the picture) to remove the cover and gain access to the KRM.
- Disconnect the XS1 and XS2 cables from the KRM board. KRM will turn off.
- Disconnect the 14-way X12 cable from the KRM board.
- Connect the X12 cable to the corresponding cable of the retrofit kit (5KT-120).
- Connect the other end of the retrofit kit cable to the KRM board (X12 connector).
- Disconnect theRJ11 cable of the telephone line from the KRM board.
- Sometimes the telephone line is connected directly to the trailing cable (wires n° 15 and 16, often orange and white colors).
- Connect the telephone line to the RJ11 connector of the retrofit kit.
- Connect the terminal blocks of the retrofit kit to the Helpy 2W-V 12V MK.
- Help 2W-V 12V MK can be installed on the top of the car. . Please make sure the microphone is placed in correspondence with a car hole and the audio quality is good.
- In any case Helpy 2W-V 12V MK can be installed facing upwards.
- Connect the XS1 and XS2 cables to the KRM board.
- Help 2W-V 12V MK will turn on (the red LED flashes briefly once every 3 seconds).
- If KRM starts an alarm, disconnect the XS1 and XS2 cables for few seconds.
Note : for basic programming see the table
Connecting the car-top and car-bottom pushbuttons
- Disconnect the XS1 and XS2 cables from the KRM board. KRM will turn off.
- Disconnect the XC9B and XC9C cables from the KRM board.
- Disconnect the two SPOX connector from the retrofit kit (5KT-120).
- Insert the two SPOX connectors into the XC9B and XC9C connectors on the KRM board.
- Connettere i cavi XS1 e XS2 alla scheda KRM. Helpy 2W-V 12V MK si accende (il LED rosso lampeggia una volta ogni 3 secondi).
- Connect the XS1 and XS2 cables to the KRM board. Helpy 2W-V 12V MK will turn on (the red LED flashes briefly once every 3 seconds)
Note : Helpy 2W-V 12V MK is factory programmed for normally closed car- top and car-bottom pushbuttons (4110).
KCEAPM INSTALLATION
-
Open the Maintenance Access Panel (MAP), integrated in a landing door or wall-mounted, to gain access to the KCEAPM.
-
Disconnect the XM31 (signals) and X1 (telephone line) cables from the KCEAPM. KCEAPM will turn off.
-
Cut the yellow wire of the 5KT-120 retrofit kit cable (wire connected to pin n° 8 of the male Molex connector).
-
Open the Car Operating Panel (COP).
-
Lower the cable of the retrofit kit (5KT-120) from the car top.
-
Disconnect the 14-way cable from the J2 connector.
-
Connect the 14-way cable to the corresponding cable of the retrofit kit (5KT-120).
-
Connect the other end of the retrofit kit cable to the J2 connector.
-
Install Helpy 2W-V 12V MK on the top of the car.
Please make sure the microphone is placed in correspondence with a car hole and the audio quality is good. -
In any case Helpy 2W-V 12V MK can be installed facing upwards.
-
Helpy 2W-V 12V MK si accende (il LED rosso lampeggia una volta ogni 3 secondi).
Connecting the telephone line
- Open the Base Unit Module installed at the top of the lift shaft.
- Disconnect the telephone line from the Base Unit Module.
- Disconnect the 4-way cable from the Base Unit Module.
- Connect the 2 wires of the telephone line to any of the 2 wires in the 4-way cable
- Disconnect from the LCEKNX KoneXion car interface (in the middle of the controller, in the lift shaft) the 4-way cable that comes from the Base Unit Module .
- Disconnect the XC20 connector.
- Connect the 2 wires of the 4-way cable used for the telephone line to the XC20 cable (trailing cable).
- Open the Car Unit in Metal Box installed on the top of the car.
- Disconnect the brown and blue wires from the Car Unit.
- Connect the brown and blue wires to the LTI terminals of Helpy 2W-V 12V MK.
Connecting the pushbutton
- Disconnect the white connector XB18 (10-way cable) from the box installed on the top of the car.
- Cut the wire marked with number 5.
- Connect both ends of wire 5 to a side of a 12 V relay coil.
- Connect the other side of the relay coil to earth/ground.
- Reconnect the connector XB18
- Connect the normally open contacts of the relay to AL1 and — terminals of Helpy 2W-V 12V MK.
- Connect the diode between +12 and C terminals.
Note : for basic programming see the table
BASIC PROGRAMMING
Access to programming | *0# |
---|---|
1 st telephone number for emergency call | 210112 < _telephone number |
_ #
2 nd telephone number for emergency call| 210212 < telephone number #
3 rd telephone number for emergency call| 210312 < telephone number #
telephone number for periodic test call (CLI mode)| 210434 < telephone number > #
Record identification message| 7101 <registrare/ record >
Listen to identification message| 7201 < listen >
Emergency call button delay| 42X (X=3-9 seconds )
Emergency input AL1 normally closed/open| 4100 normally closed
Exiting the programming| *0#
Documents / Resources
|
esse-ti 5HK-300 Kone Retrofit
Kit
[pdf] Instruction Manual
5HK-300, Kone Retrofit Kit, 5HK-300 Kone Retrofit Kit, Retrofit Kit
---|---
Read User Manual Online (PDF format)