esse-ti 81-28:2018 Alarm System Elevators Compliant with European Standard User Guide
- June 9, 2024
- esse-ti
Table of Contents
- esse-ti 81-28:2018 Alarm System Elevators Compliant with European
- Product Information
- Product Usage Instructions
- DESCRIPTION
- TERMINAL BLOCKS
- CONNECTING THE SPEAKER UNITS
- CONNECTING THE EMERGENCY CALL BUTTONS
- **Powered pushbuttons (12-24 Vdc) – 2 solutions
- CONNECTING THE FILTER INPUT
- CONNECTING THE INDICATOR LIGHTS
- OTHER CONNECTIONS
- WIRING DIAGRAMS
- TURNING ON / TURNING OFF
- MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION
- USING THE RESET BUTTON
- PROGRAMMING
- USE
- SIGNALS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
esse-ti 81-28:2018 Alarm System Elevators Compliant with European
Standard
Product Information
The Helpy Compact-Q is an alarm system for elevators that is compliant with the European Standard EN 81-28:2018. It is specifically designed for installation on the car roof and comeswith a built-in loudspeaker connector, device status LED, reset pushbutton, serial port for PC connection, alarm pushbutton, received alarm indicator light, pushbutton connection cable, microSD card slot, jumpers J16/J17, connector not used, given alarm indicator light, terminal blocks, wiring exit slot, built-imicrophone, screw for cover fixing, built-in loudspeaker connection cable (connect to A), built-in loudspeaker, pushbutton connection cable (connect to G), and microphone hole. The Helpy Compact-Q alsohas a built-in speaker unit and can connect up to 2 passive speaker units or cables with a microphone on top and bottom of the elevator car.
Product Usage Instructions
To download user guides in other languages, scan the QR code or visit https://www.esse-ti.it/en/manuals. The Helpy Compact-Q comes with a built-in speaker unit that can be connected to the ALT2 terminal block using MIC2 or MIC3. Passive speaker units or cables with a microphone can also be connected to the Helpy Compact-Q with maximum distances of 6m (with shielded cable) and cable length of 3m (red wire connects to MIC2 or MIC3 and white wire is not used). If the built-in pushbutton is present, the pushbuttons of the pit, top, and bottom of the elevator car can only be connected to AL1 terminal block if they are voltage-free NO. If the built-in pushbutton is NOT present, the pushbuttons of pit, top and bottom of the elevator car can only be connected to AL1 terminal block if they are voltage-free contact pushbuttons (NO or NC) or powered pushbuttons. The pushbuttons of pit, top and bottom of elevator car can only be connected to AL2 terminal block if they are voltage-free.
To download User guides in other languages please scan the QR-code or visit https://www.esse-ti.it/en/manuals
DESCRIPTION
Autodialer specifically designed for installation on car roof.
- Built-in loudspeaker connector
- Device status LED
- Reset pushbutton
- Serial port for PC connection
- Alarm pushbutton
- Received alarm indicator light
- Pushbutton connection cable (connect to T)
- Micro SD Card slot
- Jumpers J16 / J17
- Connector not used
- Given alarm indicator light
- Terminal blocks
- Wiring exit slot
- Built-in microphone
- Screw for cover fixing
- Built-in loudspeaker connection cable (connect to A)
- Built-in loudspeaker
- Pushbutton connection cable (connect to G)
- Microphone hole
NOTE: the presence of the button is depending on the model of Helpy Compact-Q purchased
TERMINAL BLOCKS
- LTI PSTN-line or universal gateway input
- LTI PSTN-line or universal gateway input
- Ground terminal for PSTN-line
- LTO Output for domestic telephone line
- LTO Output for domestic telephone line
- TEL Local telephone
- — Negative
- RL1 NO Relay (normally open contact)
- RL1 NC Relay (normally closed contact)
- RL1 C Relay (common contact)
- + Power supply input (10 Vdc – 30 Vdc)
- — Negative
- AI Given alarm indicator light (12 Vdc or 0 Vdc via jumper J16)
- AR Received alarm indicator light (12 Vdc or 0 Vdc via jumper J17)
- +12 12 Vdc output (max. 100 mA)
- C Common terminal for inputs AL1 and IN1
- — Negative
- AL1 Alarm input(1) 1
- AL2 Reset input(2) 2 (freely programmable)
- IN1 Filter input(2) (freely programmable)
- ALT2 Output for connecting loudspeaker of passive speaker unit (top or bottom of elevator car)
- MIC2 Input for connecting microphone of passive speaker unit or single microphone (top or bottom of elevator car)
- MIC3 Input for connecting microphone of passive speaker unit or single microphone (top or bottom of elevator car)
- — Negative
- when the built-in pushbutton is present, it allows to connect voltage-free contact pushbuttons NO; when the built-in pushbutton is NOT present, it allows to connect voltage-free contact pushbuttons (NO or NC) or powered pushbuttons
- allows to connect voltage free contacts (NO or NC)
CONNECTING THE SPEAKER UNITS
Helpy Compact-Q comes with a built-in speaker unit.
It is also possible to connect to the Helpy Compact-Q up to 2 passive speaker
units or cables with a microphone on top and bottom of elevator car.
- Make the connections as shown in the table below:
CONNECTING THE EMERGENCY CALL BUTTONS
IF THE BUILT-IN PUSHBUTTON IS PRESENT
Note: the built-in pushbutton is normally open and cannot be modified. The pushbuttons of pit, top and bottom of elevator car can only be connected to AL1 terminal block if they are voltage-free NO. The pushbuttons of pit, top and bottom of elevator car can only be connected to AL2 terminal block if they are voltage-free.
- Note: the reset input (AL2) must be configured as alarm input with the “Inputs setting” programming (codes 390 or 55).
- Note: the AL2 input can be configured as NO or NC with the “Inputs normally open/closed” programming (code 41).
- Connect, following the diagram shown below, the external pushbuttons.
IF THE BUILT-IN PUSHBUTTON IS NOT PRESENT
- Connect, following one of the diagrams shown below, the pushbuttons.
Car pushbutton
It is possible to connect (inside the elevator car) voltage free contact
pushbuttons or powered pushbuttons.
Voltage free contact pushbuttons
**Powered pushbuttons (12-24 Vdc) – 2 solutions
** Other pushbuttons
The pushbuttons of pit, top and bottom of elevator car can only be connected to an AL1 terminal block if they are of the same type as the car pushbutton (voltage free or powered, normally open or normally closed). The pushbuttons of pit, top and bottom of elevator car can only be connected to AL2 terminal block if they are voltage-free.
Note: the reset input (AL2) must be configured as alarm input with the “Inputs setting” programming (codes 390 or 55).
CONNECTING THE FILTER INPUT
It is possible to use a voltage free contact (NO or NC).
- Connect, following the diagram shown below, the filter contact.
Note: the IN1 input can be configured as NO or NC with the “Inputs normally open/closed” programming (code 41).
CONNECTING THE INDICATOR LIGHTS
Helpy Compact-Q comes with built-in indicator lights. The GIVEN ALARM INDICATOR LIGHT (yellow) switches on after pressing the emergency button to indicate the beginning of the alarm procedure. The RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered. It is also possible to connect external indicator lights.
- Connect, following one of the diagrams shown below, the external indicator lights to the Helpy Compact-Q.
Output 12 Vdc (factory setting)
Output 0 Vdc
OTHER CONNECTIONS
CONNECTING THE TELEPHONE LINE
PSTN line or universal gateway (2G/3G/4G)
- Connect the ground terminal (indicated by ), to a ground socket in order to increase the PSTN line protection.
- Connect the telephone line to LTI terminals.
CONNECTING THE LOCAL TELEPHONE
- Connect the local telephone (for programming and managing the device) to TEL and – terminals (irrespective of the polarity).
CONNECTING THE RESET CONTACT
It is possible to use a voltage free contact (NO or NC).
- Connect the reset contact to AL2 and – terminals.
CONNECTING THE RELAY
- Connect the external contact to RL1 NO (or RL1 NC) and RL1 C terminals.
WIRING DIAGRAMS
TURNING ON / TURNING OFF
TURNING ON
- Connect the external (12 Vdc – 30 Vdc) power supply to + and — terminals. Helpy Compact-Q lights up and the device status LED starts flashing.
TURNING OFF
- Disconnect the external (12 Vdc – 30 Vdc) power supply from + and — terminals. The device status LED turns off.
MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION
PROGRAMMING
-
Access to programming: lift the local telephone handset and dial *0#.
The programming activated message will be heard. -
Program a telephone number for the emergency-call alarm: dial 2104112
# . -
Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial 7101 and, after the “Correct” message, pronounce the message and hang up.
-
To listen again to the previous message: lift the handset and dial 7101 .
-
Make an external call to check the PSTN line or the universal gateway is properly working: dial 0 and digit the telephone number to make a test call.
TESTING THE ALARM PROCEDURE
- Press the emergency call button for more than 3 seconds (factory value). The alarm starts.
ANSWERING THE ALARM
Note: the activation mode of the communication with the trapped person can be configured with the “Two-way communication mode during an alarm” programming (code 78).
- 1st mode: automatic two-way communication established after messages (factory default)
- Answer by the called party. The two-way communication mode will be activated after the voice messages.
- Speak with the trapped person.
- 2nd mode: two-way communication established after input of “Communication activation” code
- Answer by the called party. The voice messages will be heard.
- Press to speak with the trapped person.
- 3nd mode: immediate and automatic two-way communication (no messages)
- Answer by the called party.
- Speak with the trapped person.
RESETTING THE ALARM
Note: the alarm reset mode can be configured with the “Alarm reset mode” programming (code 77).
-
* 1st mode: reset by “End” code (factory default)
-
Press 0 to end the alarm.
- 2nd mode: automatic reset
-
Hang up (or press 9 ) to end the alarm.
- 3nd mode: automatic reset with local acknowledgment
-
Hang up to end the call.
-
Press the reset push button or close the reset input to end the alarm. An end-of-alarm call will be generated.
-
Answer by the called party.
-
Press 9 .
Without local acknowledgement, the alarm is automatically ended after 6 hours. -
Note: the reset input can be configured with the “Inputs setting” programming (codes 390 or 55).
-
Note: in case it should not be possible to stop the alarm procedure remotely (i.e. the entered telephone number is incorrect) simply lift the handset of the local telephone and dial *
# (by factory default: *0# ) or press the reset pushbutton.
USING THE RESET BUTTON
Note: the reset operation does not alter the previously set parameters.
Use of the reset pushbutton (C in the picture at page 2):
- Pressing shortly Allows to interrupt an alarm call. By pressing shortly you get the same result as lifting the handset of the local telephone and entering *
#. - Pressing longer (10 seconds) Allows to reset the device. By pressing longer, the Helpy Compact-Q will be re-started with no need to disconnect the power supply.
Note: it is also possible to reset the device through the code 995*0#.
PROGRAMMING
In the tables below:
- INST indicates that the programming is allowed for the installer
- OPER indicates that the programming is allowed by the maintenance technician
- factory default values are highlighted in bold
Basic programming
Advanced programming
Local programming via e-stant software
It is possible to program Helpy Compact-Q via computer by using the USB/serial
proprietary cable and the dedicated e-stant software. e-stant software also
allows to:
- update the firmware of the Helpy Compact-Q
- customize the messages of the Helpy Compact-Q
- set a micro SD card to use for programming, customizing the messages and updating the firmware of the Helpy Compact-Q. e-stant can be downloaded at the following link: https://www.esse-ti.it/en/download/software-request
Local programming via micro SD card
The micro SD card properly set allows to:
- program the Helpy Compact-Q
- update the firmware of the Helpy Compact-Q
- customize the messages of Helpy Compact-Q.
To use of the micro SD card see the relating instructions.
Remote programming
It is possible to program the Helpy Compact-Q remotely:
- via telephone (DTMF)
- using EPT protocol-compliant software (DTMF)
USE
Local use
- : lift the local telephone handset
- : lift the local telephone handset and dial *0# to access programming
Use remotely with Helpy Compact-Q at rest
-
Call Helpy Compact-Q and wait for a response.
-
Listen to the elevator identification message, if present.
-
Dial 11 to speak with all speaker units.
or -
Dial *
-
All of the programming and functions below can now be performed:
SIGNALS
Device status LED
Given the alarm indicator light (yellow)
Received alarm indicator light (green)
Missed test call notification (EN 81-28:2018)
The Given alarm indicator light and the Received alarm indicator light flash
in opposition to indicate the failure of the automatic test call.
The flashing sequence ends after the next successful test call or emergency
call.
Given the alarm indicator light
NOTES
EU DECLARATION OF CONFORMITY
Hereby, Esse-ti S.r.l. declares that the equipment type Helpy Compact-Q is in
compliance with Directives 2014/33/EU – 2014/30/EU – 2001/95/EC.
The full text of the EU declaration of conformity is available from the
following Internet address:
https://www.esse-ti.it/en/dichiarazioni-di-conformita
Esse-ti S.r.l.
- Via G. Capodaglio, 9
- 62019 Recanati (MC) – ITALY
- Tel. +39 071 7506066
- www.esse-ti.it
- support@esse-ti.it
References
- Esse-ti - L’eccellenza del “Made in Italy” al servizio della comunicazione