esse ti ST56 INTL Alarm System User Guide
- June 9, 2024
- esse-ti
Table of Contents
ST56 INTL Alarm System
User Guide
Overall state
Explanation
For all the issues stated in this manual:
- The icon is only valid for the corresponding model host which is configured with the WIFI module.
The icon is only valid for the user who has applied alarm service in the local network alarm operation service center.
Features
- 4.3-inch IPS color display, full capacitive touch screen operation, simple style man-machine interface, and menu guidance design.
- The main interface status bar, date and time clock display, host status at a glance.
- Built-in powerful performance CPU master based on 32-bit Cortex-M3 core
- Based on the operating system with multitasking design, with a great user operation experience.
- WIFI/GSM/GPRS network alarm system, and support APP push/SMS/voice monitoring/center network, etc. multi-channel alarm ways, to ensure the alarm performance is stable and reliable.
- Support SMS arm/Disarm and parameters setting, support invoice arm/Disarm.
- Friendly APP operating experience and user interface, access to latest equipment working status.
- Up to 100 storage locations for the learning of remotes , RFID and wireless detectors. 4 wired defense zone
- Support many defense zones name such as the gate, SOS, bedroom, window, balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc.
- Support the main power failure, backup battery power shortage, tamper alarm, and other extended alarm; Support detector low battery alert & tamper alarm function.
- Door open alert.
- Support many defense zone types setting such as entry/exit zone, indoor zone, perimeter zone, 24-hour zone, doorbell, etc.
- Up to 5 groups of preset alarm phone numbers, SMS on/off, and voice on/off can be set respectively.
- External wired alarm connectors: 1 channel external wireless siren, 8 channel alarm linked wireless intelligent socket.
- APP or host can control several sockets, so control the home electrical appliances.
- Support timing arm and disarm.
- Can store and query several daily operation records and alarm records.
- GSM network automatic school, to ensure the clock is always accurate
- Support multi-language menu display, voice prompts, and alarm SMS settings.
- Can record 20 seconds message and alarm voice.
- Telephone function, support 5 groups re-dial number.
- Excellent APP operation feeling and user interface, get the device working status anytime.
- Arm/disarm, host alarm to the mobile app.
- Support APP arm/disarm remotely, parameter setting, Parts management, and intelligent socket control.
- Friendly APP operating experience and user interface, obtain the latest working state of the device at any time.
- User arm and disarm, host alarm push to APP.
- Support APP remote arm and disarm.
- GPRS real-time networking online, access to the latest working state of the equipment at any time. Automatically alarm if offline.
- Reserved remote GPRS TCP / UDP protocol channel, compatible with multiple alarm center networking protocols to facilitate network alarm.
- Center remote control.
Daily Operation Nouns
- ARM: set security task (Anti-burglar), make the host into the alert state, also known as Arming, Alert or Booting.
- Stay Arm: When users are at home, only need to alert entrances or perimeter.
- Disarm: cancel the safety task (Anti-burglar), also known as removing alarm or shutdown.
- Trigger: In the Arm state, the detector detects someone or a door is opened, it will trigger the detectors and make alarms.
- Exit delay: after setting the host to be ARM state, in order to avoid making alarms for the users leaving and passing the Arm zones, delay the alarm time.
- Entry delay: when users come back and pass the Arm zones, the host will not immediately make alarms, allowing users to Disarm the host with some time; the host will make alarms if time out beyond the Disarm.
- Alarm: when the host has the alarm assignment, it will cause the strobe alarm locally, then send the SMS alarm to the mobile defaulted, dial the mobile defaulted, push the alarm to the mobile app and send the message to the networking alarm center, etc.
APPEARANCE AND ACCESSORIES
Front
Back
Power On/Off
Function | Method |
---|---|
Power On | Push this button, it will show “welcome” which means power on |
successfully
Power Off| push this button for 3 seconds till the screen become black, means
power off successfully
SOS Button
Push this button when emergency, it will cause the strobe alarm locally, then
send the SMS alarm to the mobile defaulted, dial the mobile defaulted, push
the alarm to the mobile app and send the message to the networking alarm
center, etc.
SOS button backlight
Background light | Status |
---|---|
Circulate twinkle | Alarm |
Breathing twinkle | Alarm |
Normally on | Disarm |
Navigating Menus
Main interface function and button description
Menu Structure
Note:
- Keyboard lock open: at the main interface, no pushing within 30 seconds or pushing directly, the host will enter locked status. After locking, the user must enter a password to unlock before he can operate the host.
- keyboard background light closed: at the main interface, no pushing within 30 seconds or pushing directly host background light will be closed to save the power.
After selecting one language, the operation notice, display, and SMS message will switch to the same language, the host will restart while finished.
Initial Use
Getting started
Insert Card: insert a standard micro-SIM card into the card slot as
illustrated below
Power On: plug in the power adapter through the USB 5V interface.
Host On: when the host is off, switch to ON and welcome displays. The
host is on.
Host Off: when the host is on, switch to OFF, and black screen displays.
The host is off.
System initialization
Main menu-System Setting-Initialization. All parameters, languages, and time
zones set by users will be back to the factory default setting, and all remote
controls, detectors, RFID tags, and records will be deleted, after
initialization.
Networking IP deleted, the host is in GPRS offline statue. You’ll need to send
an SMS to reset the IP for the host to go back online.
Caution! only advised to do this when you forget operation password, host
malfunction, parameters setting mistakes, unidentified detectors, remote
controls or RFID tags learned. Initialization doesn’t work under Keypad Lock.
Menu Operation
This product is designed with a capacity touchscreen, utilizing current
sensing of the human body to function.
For features not listed in this chapter, refer to the descriptions in the
diagram above.
Functions described in this part: include the phone number setting, remote
controller add/delete, wireless detector add/delete and the external wireless
siren matching can be set by mobile app.(only with )
Adding Alarm Phone Number
The host can be set to communicate with up to 5 phone numbers, dialing and SMS
features which can be enabled/disabled separately. To set #1 phone number, for
instance:
- Keypad operation: Main Menu Phone 1st Phone, press ****to enter setting interface. You can input the alarm phone number (max.18 digits).
- Move to ****and press to set it on/off. When you set it on, the host will call this phone number when an alarm happens.
- Move to ****and press to set it on/off. When you set it on, the host will send an SMS to this phone number when an alarm happens.
- Press to confirm Setting.
Adding/Deleting Remote Controller
Push: Main menu →Parts→ Remote controller, enter the interface for remote
controller setting.
Push or for page down, it will show all the Synchronized remote
controller
Adding a new remote controller
Press **to add remote, 20-second countdown starts. Press any of the 4
buttons on the remote control so that it sends a wireless signal to the host.
When ‘Learning OK’ displays, the remote is added successfully.
When ‘Device code has been learned’ displays, it means the remote control was
added already or it has the same wireless code as the other wireless detector
added. Please change to a new remote.
Deleting a remote controller
**Press on the list of remotes to delete the remote,
Press **to delete all remotes.
Match code with/delete wireless detectors
**Press: Main→ menu →Parts Detector,enter into the detector setting
interface.
**Press or page down,it will list all the Synced wireless detectors.
Sync the new wireless detectors
**Press ,host get into the”Set Name/Mode/Number”interface.
Press choose the name of the zone for the none Sync wireless
detectors.
Press **,choose the type of the zone for the none Sync wireless
detectors. 24h Choose”Stay Arm Active”,after the arm or stay arm setting, the
detectors in this zone will alarm while be triggered. Front Door Window
Balcony 、Perimeter use this kind of detectors.
Choose“ Out Arm Active ” after the stay arm setting, the detectors in this
zones will not alarm while be triggered. Living Room 、 Bedroom and other
internal place use this kind of detectors.
Choose ” 24 Hours Active” , it will alarm while be triggered anytime, SOS
Panic、Smoke/Fire、Gas、CO、water Leakage use this kind of detectors.
Choose”Close”,it will not alarm while triggered.
For wireless doorbell, please choose”Doorbell”, It will note “dingdong”
anytime while be triggered.
24 Hours Silent: alarm sent when detectors triggered, siren muted,
recommended for SOS(PANIC),smoke,gas,CO,water leakage detectors,etc.
Stay Arm Active without Delay: when panel is armed or star armed, alarm
sent when detector is trigged without delay, recommended for door,windows,
balcony,perimeter detectors.
Out Arm Active without Delay: when panel is stay armed, alarm won’t be
sent when detector is trigged, recommended for living room, bedroom detectors.
**Press enter & edit the zone code of the none Sync wireless detectors,
please do not be repeated with the code of the other zones.
Press host will show”Synchronizing” and will get into the dialogue box
for 20 seconds cut down of the wireless detectors.
Trigger the wireless detectors and send signals to the host.
When host shows”Learning OK” means the detectors Sync successfully, it
will list all the name of the detectors, type, code and address code.
If host shows”Device code has been learned”,means the detectors have been
learned or repeated with the code of the other learned remote controller, need
to be changed.
Delete
Press the listed detectors ,delete the chosen detectors.
Press **,delete all the detectors.
Setting Name/Type of Wired Defense Zone
The host supports up to 4 wired defense zones, name and type of which can be
set separately.
Zone number for wired defense zones are not changeable and within 100-103
Setting wired zone #1 .for example:
Main Menu Parts Wired Zone, wired zone 1 enter setting。
Press **, to set name.
Press ****to set type. 24h
Stay Arm Active usually assigned to sensors on entry and exit doors,
exterior doors and windows, perimeter. Active when armed in AWAY or HOME mode.
We recommend to set Door/Window Sensor to Stay Arm Active.
Out Arm Active usually assigned to a interior area (i.e.: foyer, lobby,or
room).
Bypassed automatically when armed in STAY mode. We recommend to set PIR Motion
Detector to Out Arm Active.
24 Hours Active usually assigned to a zone containing an Emergency
Button, Smoke Sensor, CO, Water Leakage and Gas Sensors.
To used as doorbell, select Doorbell.
How to Pair a New Wireless Siren by Touchscreen
Go to Menu →Parts →Siren Learn
Press and hold the SET button of the siren until you hear two beeps, then the
siren goes into the paring mode and the light ring blinks quickly.
How to Pair a New RFID Tag by Touchscreen
Go to Menu →Parts→ RFID→ Add and enter
Synchronizing is shown, the hub goes into the paring mode and count down
the pairing time remained .
Tap the RFID Tag on the panel:
- As the serial number of RFID Tag is added to the hub, Leaning OK will be shown.
- The hub will show Device code has been learned if serial number of RFID Tag has been learned.
Go to Menu →Parts →RFID →Delete to delete the RFID Tag specified by
serial number .
Go to Menu →Parts→ RFID →Delete All to delete all the RFID Tags.
Tap√ on the touchscreen within 6 seconds. The hub shows Learn Signal Sent
and sends a transmission signal to the siren.
The siren gives four beeps of successful indication.
If you want to unbind the wireless siren with the hub, press and hold the SET
button of the siren until you hear three beeps.
How to Pair a New Wireless Socket by Touchscreen
Go to Menu →Parts →Alarm Socket
Press and hold the button of the switch until it lights up, then the
switch goes into the paring mode.
Tap on and off on the touchscreen . The hub shows and sends the
on and off transmission signals to the switch.
The siren gives three flashes of successful indication.
When a sound alarm occurs,the alarm wireless switch opens until the system is
disarmed or alarm sounder timeout occurs.
If you want to unbind the alarm wireless switch with the hub, press and hold
the button of the switch for about 10 seconds until light is off .
Smart home appliance
Full sockets
Interface press:press Socket,enter into the intelligent socket controlling
interface.
Syncing
The syncing method between the host with the socket, please refer to the”alarm
linkage intelligent socket syncing”one host can sync with several socket.
press”On” or” Off” host will have the on/off signal to control the
wireless socket.
socket which synced the host succeed, can used the host or the mobile app to
control on/off, or can do timer control for the socket.
Socket Timer
Host can set several groups timer to open/close the intelligent socket. Can
set the socket number, time, time on/off etc. in each group.
Press: Main menu Parts Socket Timer, enter the intelligent socket timer
interface.
Add the timer
Press , enter into the socket timer setting interface.
Press or+ in- ,set the socket number.
Press or +in- ,adjust the timer time.
Press the week item in set the day of the week.
Press choose timer on or off.
Press , finish the setting.
Edit
Press the serial number front of the Timer, can edit the relevant timer, same
as the above.
Wireless alarm linkage
Sync with alarm linkage intelligent socket
Press:Main menu→ Parts →alarm linkage intelligent Alarm Socket,and enter
Delete
Press behind of the timer list, delete the relevant timer.
Press delete all the Timer.
Voice Recording
Alarm Recording
You can record up to 20s voice, the host will call pre-set phone numbers and
play the voice.
Main Menu →Voice Recording →Record and Play.
The host displays “Busy, please wait”
When it displays Recording the countdown starts.
Speak to the host, make sure the voice record is simple and precise, This is
address, intrusion detected’
When finished, Voice record playing displays, and you’ll hear the
playback.
Click to save, it prompts Saving, please wait
****When “Operation succeed” displays the recording is done.
Timed Arm/Disarm
You can set auto arm/disarm based on your routine to avoid duplicated
operation in everyday life or not to forget arm/disarm.
Timed Arm
Main Menu →Clock →Timed Arm
Click + and – to set arm time (hour,minute)
Click to select “ON”.
Click to confirm.
Timed Disarm
Main Menu →Clock→ Timed disarm.
Click + and – to set arm time (hour,minute)
Click to select “ON”.
Click to confirm.
Mobile APP
Refer to Smart Life APP Quick Use Guide.
REMOTE SMS
Set parameters by SMS
The user only needs to edit the SMS in the below format and send it to the
host SIM card number to finish the setting.
* | System password | * | Address setting | Conten setting | * | Address setting | Content setting | * |
---|
One SMS can include one or several addresses and content but need to be separated by, the head and the end must be each address should be 2 digits, otherwise, it may have the unexpected result, each SMS must be less than 160 bytes, we suggest to finish all the contents in one SMS.,
address | function | Content & scope | Factory setting |
---|---|---|---|
35 | Redial times while dialing failure | 1-255 times | 1 time |
36 | bell ring times while auto receiving | 1-255 times | 1 time ( in the future |
)
38| username password correct| 0000-9999must be 4 digits| 1234
39| System password correct| 0000-9999must be 4 digits| 6666
43| parameter initialization| see note 1|
51| alarm phone 1:` setting| See note 2| closed
52| alarm phone 2nd setting| See note 2| closed
53| alarm phone 3’d setting| See note 2| closed
54| alarm phone 4th setting| See note 2| closed
55| alarm phone 5th setting| See note 2| closed
62| Search the GSM field strength| empty|
90| Set the GPRS server IP address| this setting is only valid while the GPRS
is online, see note 3| empty
92| Set the GPRS APN| this setting only be valid while the GPRS is online,
see note 4| COMMENT
93| Set domain name of the network time sever| | us.ntp.org.cn
94| Set the time difference with the standard Greenwich time| | +8
Setting comment(all the examples used the default system password:6666):
-
Parameter initialization: keep the learned remote controller, wireless detectors, and RFID cards, others recovery to the factory setting. Set the SMS content as 666643*.
-
Alarm phone number setting format: xxxxxxxxxxx,A,B
Such as: xxxxxxxxxxx is the phone number(no more than 18 digits),A: alarm voice dial switch(1-on,0-off),B: SMS alarm switch(1-on,0-off).
For Example:
Set 2 alarm phone numbers, the one 13912345678used to receive the voice dialing and SMS, the one 075581234567only used to receive the voice dialing, then the SMS content should be: 66665113912345678,1,152075581234567,1,0. -
IP address setting format should be:aaa,bbb,ccc,ddd,xxxxx
Such:as,aaa,bbb,ccc,ddd is the IP address,xxxxx is the port number,use the comma to separate for each address.
For example:
Set the GPRS network sever IP address is 116.62.42.223,port number is 2001, then the SMS content setting should be: 666690116,62,42,223,2001*. -
Set the local GSM operator GPRS access point APN
For example:
Local GSM operator GPRS access point APN is the internet. beeline.kz, then the SMS content setting should be:666692internet.beeline.kz*.
Set control panel’s name by SMS
Set one name to the host, used for the prefix for the alarm SMS, so as to
distinguish the position for each alarm host.
SMS setting format: 1234@XXestate X building, 1234 is the user password,@is
the commend words, “XX estate a building” is the content name(no more than 40
digits).
Set zones’ names by SMS
Set the name of each zona, used to distinguish each zona when the alarm
happened.
SMS setting format: 1234@XX bedroom ,1234 is the user password,@ is the
commend digit, XX is the zoning code(scope00~99), “bedroom” is the name want
to set(no more than 20 digits).
Query parameters by SMS
Alarm record
SMS format:666662* ,host echo:
SYSTEM set:
SN:| Host serial number
LANGUAGE:| Host language
ENGINEER PASSWORD:| Engineer password
USER PASSWORD:| User password
WIFI RSSI:| GSM field strength value(0 or 99means the signal is unusual)
GSM CSQ:| WIFI field strength value
Searching system 2
SMS format:666690* ,host echo:
SYSTEM set2:
APN:| Name of the GPRS access point
GPRS IP:| GPRS network IP sever & client number
NTP:| Network time sever domain name
TIME ZONE:| GMT standard time
SERVER:| Sever
Alarm phone number searching setting
SMS format:666651* ,host echo:
PHONE se1:
1:00| 1st alarm phone number, voice switch, SMS switch, general switch
2:00| 2nd alarm phone number, voice switch, SMS switch, general switch
3:00| 3rd alarm phone number, voice switch, SMS switch, general switch
4:00| 4th alarm phone number, voice switch, SMS switch, general switch
5:00| 5th alarm phone number, voice switch, SMS switch, general switch
REDIAL COUNTER:| voice alarm redial counters
Delay searching setting
SMS format:666633* ,host echo:
DELAY set:
ENTRY:| delay entering(unit: second)
EXIT:| delay quit(unit: second)
SIREN:| alarming time(unit: minutes)
Searching switch setting
SMS format:666646* ,host echo:
SWITCH set:
ARM/DISARM BEEP:| arm/disarm Beep switch(1:on,0:off)
ALARM BEEP:| alarm beep switch(1:on,0:off)
ARM/DISARM SMS:| arm/disarm SMS switch(1:on,0:off)
Learned remote controller & detector quantities
SMS format:666626* ,host echo:
DETECTOR learned:
REMOTE:| learned remote controller quantities
DETECTOR:| learned detectors quantities
RFID:| learned RFID card quantities
Phone function
Push in the main interface, and enter into the phone number dialing interface.
Push to look over the dialed phone number.
for the below status, a phone calls will be forbidden: GSM network abnormal,
arm/disarm, phone alarm be in progress.
User Daily Operation
Users can operate the alarm host in any ways as below:
On-site Remote controller, keyboards , RFID cards .
Remote SMS
Mobile phone APP
GPRS alarm center
Out arm
By remote control press the key to trigger “Out Arm”.
By keyboard: In Main Interface, press: to trigger Out Arm.
By RFID tag: In disarm mode, put the RFID card close to the sensitive
area in the bottom right corner of the alarm host.
By remote SMS: Send SMS message 1234#1 (1234 is the user password), the
alarm host will send “System Armed!” SMS to mobile phone to confirm.
By APP: In Main Menu, select the “ ” icon, and the operation for “ Arm”
is completed.
The alarm host reminder: A reminding voice “System armed” will be heard,
the Main Interface displays “Armed” and “Please exit”, and an exit time
progress bar appears.
The user should leave the alarm zone before exit time. If Arm/Disarm SMS
switch is on, the preset phone will receive an SMS of “System Armed!”.”
In Out Arm mode, all defense zones are on alert status. If there are any
defense zones is been triggered, the alarm host will generate a sound alarm.
Meanwhile, the alarm host sends alarm SMS and makes calls to a preset phone
number, and pushes alarm information to APP/GPRS alarm center. If the alarm
host learned about the alarming leakage smart plug, the plug will switch on
when alarming.
Stay arm
By remote control: press the key to trigger “Stay Arm”.
By keyboard: In Main Interface, press to trigger. “Stay Arm”
By remote SMS: Send SMS message 1234#3 (1234 is the user password), the
alarm host will send“System Stay Armed!” SMS to mobile phone to confirm.
By APP: In Main Menu, select the “ Stay Arm” icon, and the operation for
“Stay Arm” is completed.
The alarm host reminder: A reminding voice “System armed” will be heard,
and the Main Interface displays “Stay Armed”. If Arm/Disarm SMS switch ****is
on, the preset phone will receive the SMS “System Stay Armed! “.
In Stay Arm mode, only valid Stay Arm defense zones are on alert status. If any defense zones is been triggered, the alarm host will generate a sound alarm, Meanwhile, the alarm host sends alarm SMS and make calls to a preset phone number, and push alarm information to APP/GPRS alarm center. If the alarm host learned alarming. leakage smart plug, the plug will switch on when alarming.
Disarm
By remote control: press the button to trigger “Disarm”.
By keyboard: press on the main interface.
By RFID tag: in out arm/stay arm mode, put the RFID card close to the
sensitive area in the bottom right corner of the alarm host.
By SMS: Send SMS message 1234#2 (1234 is the user password), and the
alarm host will send “System Disarmed!” SMS to mobile phone to confirm.
By APP: In Main Menu, select the “ Disarm” icon, and the operation for
“Disarm” is completed.
The alarm host reminder: A reminding voice “System Disarmed” will be heard,
and the Main Interface displays “Disarmed”. If Arm/Disarm SMS switch is on,
the preset phone will receive the SMS “System Disarmed!”.
In Disarm mode, all alarm procedures will be terminated, If Arm/Disarm SMS switch is on ****, the preset phone will receive the SMS “System Stay Armed! “.If the alarm host learned alarming leakage smart plug, the plug will switch off.
SOS
By remote control: press【SOS】button on the remote control.
By keyboard: Press 【SOS】 on the main interface of the alarm host.
By APP: Select”SOS”icon in the main menu.
The alarm host reminder: The Main Interface displays “Help”. The alarm
host will generate a sound alarm, and send alarm SMS or make calling to the
preset phone numbers , simultaneously send the alarm message to mobile phone
APP or GPRS alarm center.
Confirm the operation result by SMS
ALARM & REMOTE MONITORING
The host supports multiple types of alarm. When alarm occurs, it sends alarm
messages containing the detector name and number to the user’s mobile phone,
pushes alarm information to the mobile phone APP, and sends alarm information
to the handset monitoring center. At the same time, it dials the user’s
telephone, and the user can conduct on-site monitoring and remote control
after the connection.
The host also supports the following alarm classes
Main power failure (the alarm is effective after the main power failure
lasts for 5 seconds)
Anti-prying alarm (alarm after separation of main engine wall mounting
bracket and main engine)
Spare battery power shortage (The alarm is valid when the spare battery
voltage is less than 3.45V and lasts for 10 seconds under the condition of
main power failure.)
Main power recovery.
SMS Alarm
Alarm occurred, host will send SMS manger to the preset phone numbers,should
Auto Dial Number Setting
When alarm occurs, host will dial the preset phone numbers. (dial switch
should be opened), after user answered, host will displays the current alarm
type first, if there is a default recording, it will have voice notice “Press
1 is arm, Press 2 is disarm, Press 3 to monitor, Press 4 to talk”. If user
finds the misinformation, press 2 to disarm and end the alarm progress. Users
can also press 3 to close the scene alarm. Just hang up the phone without
monitor.
If the user fails to answer or dial, the host will continue to dial the preset
phone according to the preset number of dials until the user receives the
call.
Preset Telephone Remote Calls Host
When several sets of telephone numbers preset by the host actively call the
alarm host, the host will automatically connect, after the call is connected,
the host can monitor the on-site scene or control the host according to voice
prompts.
Mobile app alarm recieving procedure
When alarm occurs, panel sends push notification to your mobile phone. Users
can check the alarm type in the APP main menu. Tap on ‘Alarm Info’ to check
all records of panel operations and alarm logs.
Networking Alarm Receiving Procedure
When alarm occurs, host will send the alarm message to the network monitoring
center via the GPRS. The emergency response can be handled quickly after the
central police have responded to the alarm.
This function will be valid only after the host has been opened with the user
network alarm function and service.)
The IP address must be set up by using SMS, and this function will be
effective.
APN must also be set in foreign or other areas. As for the method of these two
settings, please see SMS message setting parameters).
Technical Parameters
- Input Voltage: DC5V (Micro USB Standard Interface Power Supply)
- Working Current: <140mA when the screen is off, <280mA standby current when the screen is on
- Standby Current: 0uA
- Siren Output: <560mA
- Wireless Frequency: 315/433/868/915Mhz
- Wireless Coding: eV1527
- GSM System: 850/900/1800/1900MHz
- WIFI System: IEEE802.11b/g/n wireless standard
- Spare Battery: 3.7V/1000mAh lithium battery
- Working Temperature: -10 ~ 55 ℃
- Relative Humidity: < 80% (no condensation)
- Product Size: 1609819MM (length x height x thickness)
PACKING LIST
- 1 host with the spare battery
- Micro USB 5V/1000mA standard power supply
- Others as the customer OEM requirement.
References
- Esse-ti - L’eccellenza del “Made in Italy” al servizio della comunicazione
- Dichiarazioni di Conformità - Esse-ti
- Manuals - Esse-ti
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>