MEAN WELL NSP-1600 Series 1600W Power Supply with Single Output Owner’s Manual

July 26, 2024
MEAN WELL

MEAN WELL NSP-1600 Series 1600W Power Supply with Single Output

Specifications

  • Model: NSP-1600 series
  • Power Output: 1600W
  • Output Voltage Options: 12V, 24V, 36V, 48V
  • Dimensions: 300 85 41 mm (11.8 3.35 1.61 inch)
  • Input Voltage Range: 90-264VAC
  • Efficiency: Up to 92.5%
  • Protections: Short Circuit, Overload, Over Voltage, Over Temperature
  • Warranty: 5 years

Product Usage Instructions

  1. Installation

  2. Ensure the power supply is disconnected from the mains.

  3. Mount the power supply securely in a well-ventilated area.

  4. Connect the AC input and DC output cables as per the provided specifications.

  5. Check all connections before powering on the unit.

  6. Powering On/Off
    To power on the unit, connect it to the mains power supply and switch on the power using the remote ON-OFF control or the front panel switch. To power off, simply reverse this process.

  7. Remote Sensing
    If required, connect the remote sensing wires to ensure accurate voltage regulation at the load end.

  8. Troubleshooting
    If the power supply encounters issues such as overloading or overheating, refer to the user manual for detailed troubleshooting steps. Contact customer support if problems persist.

Frequently Asked Questions (FAQ)

  • Q: What is the warranty period for the NSP-1600 series power supply?
    A: The NSP-1600 series power supply comes with a 5-year warranty from the date of purchase.

  • Q: Can the output voltage be adjusted on the NSP-1600 power supply?
    A: Yes, the output voltage level is programmable within specified ranges for different models.

  • Q: What are some common applications of the NSP-1600 power supply?
    A: The NSP-1600 power supply is commonly used in factory control systems, test and measurement instruments, laser machines, aging facilities, digital broadcasting, and constant current sources.

1600W Power Supply with Single Output

Dimension

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 92.5%
  • Forced air cooling by built-in DC fan
  • Output voltage level programmable
  • Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal
  • Built-in intelligent fan speed control
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Design refer to SEMI F47 at 200VAC
  • 5 years warranty

Applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Aging facility
  • Digital broadcasting
  • Constant current source

GTIN CODE

Description

  • NSP-1600 is a 1.6KW single output enclosed type AC/DC power supply with a 1U low profile and a high power density up to 25W/inch’. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the thermostatically controlled fan. Moreover, NSP-1600 provides vast design flexibility by equipping various built-in functions such as the output programming, remote ON-OFF control, auxiliary power, etc.
  • Model Encoding / Order Information

SPECIFICATION

MODEL| NSP-1600-12| NSP-1600-24| NSP-1600-36| NSP-1600-48
---|---|---|---|---








OUTPUT

| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 125A| 67A| 44.5A| 33.5A
CURRENT RANGE| 0 ~ 125A| 0 ~ 67A| 0 ~ 44.5A| 0 ~ 33.5A
RATED POWER| 1500W| 1608W| 1602W| 1608W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 200mVp-p| 250mVp-p| 300mVp-p
VOLTAGE ADJ. RANGE| 11.5 ~ 15V| 23.5 ~ 30V| 35.5 ~ 45V| 47.5 ~ 58.8V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1500ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)**| 16ms / 230VAC at 70% load           10ms / 230VAC at full load





INPUT

| VOLTAGE RANGE Note.4| 90 ~ 264VAC           250 ~ 400VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| 0.97/230VAC at full load
EFFICIENCY (Typ.)| 89%| 91%| 91.5%| 92.5%
AC CURRENT (Typ.) Note.4| 14A/115VAC 8A/230VAC| 15A/115VAC 8.5A/230VAC
INRUSH CURRENT (Typ.)| COLD START 35A/230VAC
LEAKAGE CURRENT| <2mA / 230VAC




PROTECTION

| ****

OVERLOAD

| 105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. After O/P voltage falls, re-power on to recover


OVER VOLTAGE

| 15.75 ~ 18.75V| 31.5 ~ 37.5V| 47.2 ~ 56.3V| 63 ~ 75V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers automatically after temperature goes down




FUNCTION

| OUTPUT VOLTAGE PROGRAMMABLE(PV)| Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). Please refer to the Function Manual.
AUXILIARY POWER| 12V @ 0.8A
REMOTE ON-OFF CONTROL| By electrical signal or dry contact  Power ON:short  Power OFF:open. Please refer to the Function Manual
REMOTE SENSE| Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual
ALARM SIGNAL| Isolated signal output for T-alarm and DC OK




ENVIRONMENT

| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes











SAFETY & EMC

(Note 6)

| SAFETY STANDARDS| UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32),CNS 15936| Class B(CISPR32) / Class A(CNS 15936)
Radiated| BS EN/EN55032(CISPR32),CNS 15936| Class A(CISPR32 & CNS 15936)
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–







EMC IMMUNITY

| BS EN/EN55024, BS EN/EN61000-6-2, BSMI CNS15598-1, design refer to SEMI F47 at 200Vac
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 4, 2KV/Line-Line 4KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods


OTHERS

| MTBF| 684.7K hrs min.       Telcordia SR-332 (Bellcore) ; 69.2K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 3008541mm (LWH)
PACKING| 1.8Kg;6pcs/11.8Kg/1.25CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
  6. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
    Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Static Characteristics

  • Derating Curve
  • Efficiency vs Load (48V Model)

Function Manual

  1. Voltage Drop Compensation

    • Remote Sense
      The Remote Sense compensates voltage drop on the load wiring up to 0.5V

    • The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.

    • Local Sense

    • The +S,-S have to be connected to the +V(signal), -V(signal), respectively, as the following diagram, in order to get the correct output voltage if Remote Sense is not used.

  2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)

    • In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE.
    • The rated current should change with the Output Voltage Programming accordingly.
    • For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.
  3. Remote ON-OFF Control
    The power supply can be turned ON/OFF individually or along with other units by using the “Remote ON-OFF” function.

Between Remote ON-OFF and +5V-AUX Power Supply Status
Switch Short ON
Switch Open OFF

Alarm Signal Output
There are 2 alarm signals, DC OK and T-ALARM, in TTL signal form, on CN1. These signals are isolated from output. The maximum sink current is 10mA.

DC OK Fail signal Power Supply Status
“High” > 3.5~5.5V Vout ≦ 77%±5%
“Low” < -0.5~0.5V Vout ≧ 80%±5%
T-ALARM Power Supply Status
--- ---
“High” > 3.5~5.5V OFF(OTP or Fan Fail)
“Low” < -0.5~0.5V ON(Normal Work)

Mechanical Specification

Mounting Instruction

Hole No.| Recommended Screw Size| MAX. Penetration Depth L| Recommended mounting torque
---|---|---|---
1| M3| 4mm| 6~8Kgf-cm
2| M4| 5mm| 7~10Kgf-cm

Control Pin No. Assignment(CN1) : HRS DF11-16DP-2DS or equivalent

Mating Housing HRS DF11-16DS or equivalent
Terminal HRS DF11-**SC or equivalent
Pin No. Function
--- ---
1 +12V-AUX
  • Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin2).
  • The maximum load current is 0.8A. This output has the built-in “Oring diodes” and is not controlled by “Remote ON-OFF”.

2| GND-AUX|

  • Auxiliary voltage output GND.
  • The signal return is isolated from the output terminals (+V & -V).

3| +5V-AUX| This pin is use for remote ON-OFF usage only.
4| Remote ON-OFF| The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF and +5V-AUX. (Note.2) Short (4.5 ~ 5.5V) : Power ON ; Open (0 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.
5| DC-OK|

  • High (3.5 ~ 5.5V) : When the Vout ≦77%±5%. Low (-0.5 ~ 0.5V) : When Vout ≧80%±5%.
  • The maximum sourcing current is 10mA and only for output. (Note.2)

6| T-ALARM|

  • High (3.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm, or when Fan fails. Low (-0.5 ~ 0.5V) : When the internal temperature is normal, and when Fan normally works.
  • The maximum sourcing current is 10mA and only for output(Note.2)

7,8,9| NC| Retain for future use.
10,11| NC| Retain for future use.
12| PV| Connection for output voltage programming. (Note.1)
13| +V (Signal)| Positive output voltage signal.

It is for local sense; it cannot be connected directly to the load.

14| -V (Signal)| Negative output voltage signal.

It is for local sense and certain function reference; it cannot be connected directly to the load.

15| +S| Positive sensing for remote sense.
16| -S| Negative sensing for remote sense.

  • Note.1: Non-isolated signal, referenced to [-V(signal)].
  • Note.2: Isolated signal, referenced to GND-AUX.

LED Status Indicators

AC Input Terminal Pin No. Assignment

Installation Manual

Please refer to : http://www.meanwell.com/manual.html
File Name:NSP-1600-SPEC 2024-02-15