MAICO PPB 30 O Endmontage Set Instruction Manual

July 27, 2024
MAICO

MAICO PPB 30 O Endmontage Set

Product Usage Instructions

Safety

Ensure to follow all safety guidelines provided in the manual before proceeding with the installation.

Installation

Follow the installation instructions provided in the manual, including any specific guidelines for mounting and electrical connections.

Setting Up Controls

Refer to the control concept section in the manual to set up and configure the controls for the PPB 30.

Example of Use

Learn about an example of how to use the product, such as controlling air supply and exhaust with direction change using RLS 45 K.

Technical Data

Understand the technical specifications of the product, including requirements for the installation location and specific data for PPB 30.

FAQ

  • Q: What is the power supply voltage for PPB 30 models?
    • A: PPB 30 O and PPB 30 K operate on 12 V, while PPB 30 RC operates on 230 V.
  • Q: What is the frequency range for the Funk-Komponenten?
    • A: The Funk-Komponenten operates in the 868.35 MHz frequency range as per EN 300220-1 standard.
  • Q: What is the protection rating for the product?
    • A: The product has a protection rating of IP X4, indicating its resistance to water splashes.

“`

Preface

1 Preface
These instructions contain important information about final installation of the slide-in modules and internal covers. Final installation takes place once the plastering and paint work is complete.
Note the enclosed safety instructions.

· For information on shell installation

PP 45 / PPB 30 shell installation instructions

· For information on the PP45/PPB 30 install-

installation of ventila- ation and commission-

tion components,

ing instructions

commissioning and

the large variety of

setting possibilities for

the ventilation system

· For commissioning software

· For information on operation
· Accessory components

PP 45 / PPB 30 operating instructions
installation instructions enclosed with the accessories

Further instructions and videos · Brief instructions for changing filters, setting
ventilation levels and operating modes
· Video – PP 45 Connecting the internal cover
· Video – PP 45/PPB 30 filter change
· Video – Connecting controls
· Video – Installation and teaching-in radio switch DS 45 RC
· Videos – RLS 45 K Service menu, RLS 45 O Service menu, RLS 45 RC Service menu
· Video – PP 45 RC Teaching-in master and slave
· Video – PP 45 RC, PPB 30 RC installation

Safety

· Read these instructions and the enclosed safety instructions carefully before installation.
· Follow the instructions.
· Pass these instructions on to the owner/operating company for safekeeping.

Scope of delivery

Scope of delivery depends on system configuration. PPB 30 O, PPB 30 K, PPB 30 RC ventilation unit
Internal cover, complete: Housing, 2x G3 air filter and front cover.
Slide-in module including 2 fan units and 2 ceramic heat exchangers.
1 extension duct, 200 mm long; 1 centring ring; 2 sealing strips.
1 internal housing drilling template.
These installation instructions.

Intended use

PPB 30 ventilation units with heat recovery are used for air ventilation and air extraction of apartments, offices and similar rooms. They are suitable for new buildings as well as renovation work. The units are designed for 24h operation. The housing unit’s ventilation system should be configured in accordance with DIN 1946-6.
PPB 30 are balanced ventilation units, which are the ideal choice for use in exhaust air rooms (bathroom, WC or kitchen with windows) and ventilate and extract air from the rooms at the same time. Exhaust air mode is started automatically depending on the setting or can be started manually at the touch of a button.
PPB 30 are stand-alone units or can be used in groups with other PPB 30/PP 45 units. PPB 30 units have degree of protection IP X4. The protection zone must be determined depending on the unit variant used.
PPB 30 are installed in exterior walls (wall thickness 320-790 mm, installation position with slight incline towards the exterior wall) and are connected to a permanently wired electrical installation.
The PPB models “O” for Object, “K” for Comfort and the Radio Version “RC” are available. The units are operated using an RLS…/ DS 45 RC room air control suitable for the type.

Application example

PPB 30 O Operation with RLS 45 O or RLS 45 K control. PPB 30 K with RLS 45 K control. PPB 30 RC units are operated using a DS 45 RC radio switch (alternatively with RLS 45 K + radio extension module PP 45 EO).
Not possible / not permissible: The operation of PPB 30 K units in combination with an RLS 45 O control; A combination of PPB 30 K with exhaust air units (e.g. ER…/ECA…); A combination of PPB 30 O and PP 45 O/K units at the fan interface (Fan1/Fan2).

Combined with PP 45 single-room ventilation units for supply air rooms, a decentralised ventilation system for flats can also be produced for redevelopment projects.
The PP 45 units ensure an increased supply of air and therefore balanced ventilation, even if exhaust air mode is sometimes used.
Example: Combination of PPB 30 K + PP 45 units

RLS 45 K3 operating modes (heat recovery, cross-ventilation, automatic mode), 5 ventilation levels, time-limited intermittent ventilation, time-limited switch-off, safety shutdown, ModBus, configuration with PC (USB). PP 45 EO radio module can be added to integrate radio sensors.
RLS 45 O3 operating modes (heat recovery, cross-ventilation, automatic mode), 5 ventilation levels, configuration using service menu.
A PPB 30 external cover with integrated condensate drain is required for installation with a wall sleeve.
The fan/heat exchanger unit is designed as a duct mounting and can be removed for repair and cleaning purposes.
PPB 30ventilation units are only intended for domestic use and similar purposes. No other or additional use is intended.
5 Application example
Ventilation solution for a 3-room flat with PPB 30 K ventilation units for the bathroom and PP 45 ventilation units for living spaces
The PPB 30 in the bathroom ventilates and extracts air from the room, at the same time, in balanced mode. A fan in the unit extracts air and first transfers the exhaust air heat to the heat storage tank. Another fan in the unit pumps the supply air into the room across the heat storage tank, which gives off this heat. Every 60 seconds, the air direction changes, thereby permitting a ventilation mode with constant heat recovery.
Intensive ventilation can be activated via a humidity sensor or manually with a button if the humidity is high and/or if the air quality is inadequate.
Pure exhaust air mode is also possible and here the two fans pump out humidity (no heat recovery).

1 PP 45 unit with alternating operation for continuous ventilation of living spaces
2 PPB 30 K unit with balanced operation for continuous ventilation in the bathroom
3 Room air control RLS 45 K
Supply air and exhaust air with change of direction
Outside and outgoing air with change of direction

Technical data

6 Technical data

6.1 Requirements at the installation site
· Ambient temperature – 15 °C to + 40 °C.
· Airstream temperature, max. 40 °C.
· Max. permissible humidity in installation room of 90 % (at 20 °C, non- condensing).
· A level and solid wall surface is needed for wall installations.
· For filter changes, ensure sufficient space to work in front of the unit.
· Do not drill core drill hole for unit assembly and do not drill fixing points on external and internal covers in load-bearing components, such as in the lintel or ring beam.

6.2 Technical data for PPB 30

External diameter

DN 160

Length of wall sleeve

PP 45 RHK: 500 mm PP 45 RHL: 800 millimeters

Wall thickness

320 ­ 790 mm

Air filter

Filter class ISO 16890
ISO coarse 45 % (G3) 2 items

Air volume/unit

26 m³/h

Degree of protection IP X4

Sound pressure level: 18 / 32 / 41 / 45 / 49 at distance of 1 m, dB(A) free- field conditions (ventilation levels 1 5)

Rated voltage

PPB 30 O, PPB 30 K: 12 V
PPB 30 RC: 230 V

Power frequency

50/60 Hz

Volumetric flow in heat recovery mode, ventilation levels 1 to 5

5 / 12 / 18 / 22 / 26 m³/h

Volumetric flow in ex- 45 m³/h haust air mode (no heat recovery unit)

Power consumption 1.7 / 2.5 / 3.4 / 4.4 / 5.3 W

Degree of heat provi- 73.3 % (level 3) sion

SPI

0.19 W / (m³/h)

SEC value

A (-39,71 kWh / (m²*a))

Permissible ducting lengths with wired connection

From star point, max. 25 m per ventilation unit

Weight of slide-in module, cpl.

3.6 kg

Radio components: Frequency range (in acc. with EN 300220-1)

868.35 MHz

Radio receiver with in- Do not mount on the

ternal antenna

wall side of the trans-

mitter

“Wireless” operating

distances in the building are dependent on

up to:

the building materials

used:

DS 45 RC PP 45 RC

30 m

PP 45 EO PP 45 RC

30 m

PP 45 RC PP 45 RC

30 m

With signal amplifica- 40 m tion on EnOcean radio sensors and radio switches with EEP protocol

For more technical data rating plate.

33

7 Unit overview and connection options

7 Unit overview and connection options

The following tables show the possible number of components and how they can be combined.

7.1 Combinations K1­K18 (RLS 45 K)

Ventilation PP 45 O /

unit,

PP 45 K

sensor

PPB 30 O PPB 30 K

Combina- Interface Interface RS 485 tion no. Fan1/Fan2 Fan1/Fan2 bus

K1

2

K2

3

K3

4

K4

5

K5

6

K6

1

K7

2

K8

3

K9

1

K10

2

K11

3

K12

2

1

K13

3

1

K14

4

1

K15

2

2

K16

1

1

K17

2

1

K18

1

2

Exhaust air units, e.g., ER/ ECA
230 V input on RLS 45 K
1 1 1 1 1 1 1 1

External Internal sensors sensor (PP 45 HY, PP 45 HYI CO2, VOC) and LT

RS 485 bus

I2C bus

EnOcean extension module PP 45 EO*
RS 485 bus

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

0-3

0-1

0-1

Additional functions
K1-K8: Supply air function for ER exhaust air mode
K9-K11: Volumetric flow compensation for exhaust air mode via ALD exterior wall air opening
K12-K18: Supply air function for PPB 30 K exhaust air mode.
Note: Volumetric flow compensation only possible for 1 PPB 30 K unit.

  • If using PP 45 EO, a max. of 8 radio sensors and a max. of 4x PP 45 RC (master) can be taught-in.

34

8 Installation

7.2 Combinations K20­K27 (RLS 45 O)
Ventilation unit, PP 45 O / PP 45 K PPB 30 O sensor

Combination no.
K20 K21 K22 K23 K24 K25 K26 K27

Fan interface Fan1/ Fan2
2 3 4 5 6

Fan interface Fan1/ Fan2
1 2 3

External sensors Internal sensor (PP 45 HY, CO2, PP 45 HYI VOC) and LT

RS 485 bus

I2C bus

0-3

0-1

0-3

0-1

0-3

0-1

0-3

0-1

0-3

0-1

0-3

0-1

0-3

0-1

0-3

0-1

Additional functions K25: Exhaust air mode possible with 1x PPB 30 O + RLS 45 O. To start, press the optional ventilation level button for > 2 seconds.

7.3 EnOcean combinations K30 (radio)

Ventilation PP 45 RC unit, sensor

PP 45 O / PP 45 K

Exhaust air Exhaust air EnOcean ex-

units, e.g.,

units, e.g.,

ternal wireless

ER… / ECA… ER… / ECA… sensors

Combination DS 45 RC no.

RLS 45 K + PP 45 EO

PP 45 ACT

230 V input

EnOcean wireless

K30

Any

1

0-8

Additional functions K30: Any number provided they are within range. Supply air only from 2 PP 45 RC units. *Only wired exhaust air units are permitted (do not use RC exhaust air units).

Installation

· With wall thicknesses of 500-790 mm, use the optional PPB 30 VS extension kit. When installing, use the centring ring provided for the extension.
· Only mount internal cover on flat surfaces and without any distortion.
· The appropriate mounting material must be supplied on site.

8.1 Installation information
· Only use slide-in module in wall sleeve with appropriate incline to the exterior wall Shell installation instructions.
· The slide-in unit (slide-in module + extension duct) must be appropriate for the wall thickness, to avoid a ventilation short-circuit (lack of air). To ensure this, shorten the extension duct accurately.

· For prescribed connection lines Connection and wiring diagrams [} 80]: · Grid connection and 230 V input: Type NYM-J 5G1, 5 mm² · Control cables: type J-YSTY, 0.8 mm, 4 wires. Max. 25 m from star point, up to star point max. 4 m
· Imbalance may arise if the maximum stated cable lengths are exceeded. Observe installation requirements relating to cable lengths and types.

35

8 Installation

· The ventilation units may only be operated using the voltage and frequency shown on the rating plate. For rating plate, see RLS 45 O or RLS 45 K control or PPB 30 RC ventilation unit. Operating voltage for PPB 30 O / PPB 30 K units = 12 V DC.
· Units/controls not suited for outdoor use. Protect ventilation units/controls from moisture and wetness. · Use RLS/DS controls only outside protection zones 0, 1 and 2. · Use PP 45 ventilation units only outside protection zones 0, 1 and 2. · Use PPB 30 O PPB 30 K ventilation units only outside of protection zone 0. · Use PPB 30 RC ventilation units only outside of protection zones 0 and 1.
· PPB 30 O units are connected directly to the fan interface (Fan1/Fan2) of the RLS 45 O or RLS 45 K control. For electrical connection Connection diagram [} 82].
· PPB 30 K units are connected to the RS 485 bus of the RLS 45 K control. If using several PPB 30 K on an RLS 45 K, the PPB 30 K units should be addressed using the DIP switches on the board (address 0 = unit 1, address 1 = unit 2, address 3 = unit 3). For electrical connection
and position of the DIP switches Connection and wiring diagrams [} 80].
· PPB 30 RC units are connected to 230V/50Hz
(for electrical connection Connection and wiring diagrams [} 80].) The control is carried out with DS 45 RC radio control.
· The two connecting cables of the PPB 30 fans (in the slide-in module) are already fully wired (8-pin, coded connector plug to avoid mixing up the sockets). They are connected to the circuit board in the ventilation unit.
· RLS room air control with plug-in connection terminals for ventilation unit connecting cables. Connection terminals can be taken off for wiring.
· When using the sensor-based automatic dehumidification function, exhaust air mode runs until the humidity falls 3% below the maximum humidity value limit. Volumetric flow compensation with other PushPull units is undertaken.
· Manually switched exhaust air mode or manually switched intensive ventilation is possible on PPB 30 K units with a button or switch (provided by the customer). When using the switch, the start delay can be set. The specialist installer can set parameters for the duration of

the manually switched functions and the start delay using the commissioning software. Volumetric flow compensation is undertaken with the other PushPull units on the fan interface. · Manually switched exhaust air mode or intensive ventilation is possible on PPB 30 RC by means of DS 45 RC or a button (provided by the customer). The duration of the manually switched function can be parameterised by the specialist installer via the service mode. · Exhaust air mode on a PPB30 O in combination with an RLS 45 O can be activated by pressing the “Ventilation level” button for more than 2 seconds. Exhaust air mode generally lasts 10 minutes. · Exhaust air mode is only possible with a PPB 30 unit type and when 1 unit is used (setting in service menu). The measurements will be incorrect if the installation location of the control and external sensors is inappropriate. Avoid disturbing influences and direct sunlight. · RLS 45 O / RLS 45 K with LEDs. For RLS 45 K, the brightness can be set and/or switched off using the commissioning software. If people are being disturbed by bright LEDs (in bedrooms, for example), choose a suitable installation location. · Quiet changeover noises when the fans change direction of rotation. Do not install PPB 30 in bedrooms.
8.2 Unit structure and positioning
1 Wall sleeve 2 Slide-in module 3 Fluid separator, outside 4 Centring ring 5 Extension duct: Standard 200 mm, with op-
tional PPB 30 VS extension kit, 500 mm

36

8 Installation

6 Centring ring, in scope of supply of PPB 30 VS extension kit Centring ring, in scope of supply of PPB 30 VS extension kit
7 Sealing strip for external cover

8.3 Shortening extension duct
The following preparations must have been completed Shell installation instructions.
1. The wall sleeve has been installed in such a manner that it protrudes 5…10 mm beyond the finished plaster of the exterior wall and has an incline of 1 to 2 % to the exterior wall. The sleeve must be sealed from the wall with silicone.
2. The external cover is already mounted.
3. The control cables of ventilation units, sensors and accessory components must be routed in the empty tubes.
To shorten the extension duct, proceed as follows:

6. Insert slide-in module into wall sleeve with fitted internal housing and slide onto extension duct so that the fluid separator is firmly connected.
7. Accurately measure distance between internal cover and wall (dimension “x” in mm).
8. Take all components out of wall sleeve.

CAUTION Risk of injury when handling housing parts with sharp edges, e.g. burrs. Wear protective gloves.
9. Saw extension duct to x + 5 mm. Deburr saw cut.

8.4 Gluing on sealing bands

4 Centring ring
5 Extension duct
6 Centring ring
4. Slide extension duct into wall sleeve, with centring ring(s), up to stop on the external cover. Ensure that the centring ring is positioned as far inside as possible. With PPB 30 VS extension, use two centring rings (position as far inside and outside as possible).
5. Take off front cover of internal cover’s housing. To do this, press the two locking levers on the underside up a little and take off the cover.

3 Fluid separator, outside
3.1 Sealing strip
5 Extension duct
7 Sealing strip
1. Glue sealing strips onto the outside of the duct end of the fluid separator and/or onto the outside of the extension duct so that it terminates flush at the face end.
NOTICE Damage to brickwork caused by condensate if the sealing strips are fitted incorrectly. Glue in sealing strips correctly.

37

8 Installation
8.5 Installing the PPB 30 O/K/RC slide-in module with extension duct

1. Produce fixing holes for the internal cover. Use enclosed drilling template. Note the TOP unit position. Insert dowel.
2. Slide extension duct into wall sleeve, with centring ring(s), up to stop of the external cover. Ensure that the centring ring is positioned as far inside as possible. If needed, fix centring ring on wall sleeve with adhesive tape.
3. With PPB 30 VS extension, use two centring rings. The sealing strip must fit tightly in the external cover.
4. Remove electronics compartment cover (2 screws).
5. Use thin screwdriver to pierce cable grommet in internal housing.
NOTICE Damage to unit from water ingress if the connecting cable is incorrectly fed into the internal housing or if the cable grommet is not fitted correctly. Pierce cap of cable grommet so that it can tightly seal the power cable. The cable grommet must be correctly attached in the housing.
6. If using PPB 30 K units and connection of an optional button or switch, the second input is used with the relevant grommet Figure.

7. Slide complete slide-in unit a little into the wall sleeve with the internal cover. Guide connecting cable(s) through cable grommet(s) into terminal compartment.
8. Slide complete slide-in unit into the wall sleeve with the internal cover until stop is reached. The sealing strip must fit tightly in the extension duct.
9. Screw internal cover down to wall with 4 screws. Note the TOP unit position. Suitable mounting material is to be provided by the customer.
10.Make the unit connection according to the connection diagram in the appendix [} 80] Observe the unit variant.
11.PPB 30 K / PPB 30 RC: If desired, connect a button to start the exhaust air mode or intensive ventilation function Wiring diagrams in appendix.
12.When connecting multiple PPB 30 K: Address the units at the DIP switch Connection diagrams in the appendix [} 80].

38

8 Installation

PPB 30 K unit #1 PPB 30 K units #2 PPB 30 K units #3

8.6 230 V electrical connection
· The two internal EC fans of the ventilation unit are supplied with 12 V DC and activated using a PWM signal (0 ­ 5 V).
· The power supply for the ventilation units is provided by the room air control for up to 6 fans (up to 3 PPB 30).
· The room air control is supplied with 230 V AC.
· The unit variant PPB 30 RC has a fully integrated control unit with 230 V connection.

13.Fit electronics compartment cover and screw down (2 screws).
14.Plug in plugs (8-pin) of both fan connecting cables directly onto the circuit board. The plugs are coded and cannot be confused. Insert connecting cables in intended slot in the housing. With PPB 30 K/ PPB 30 RC units, ensure that the humidity sensor is not covered.
15.Ensure that the two G3 air filters are correctly inserted in the holders.
F Front cover R Locking lever 16.Attach front cover and swivel down until the front cover engages at the two locking levers.

Note the following safety instructions.
DANGER Danger of electric shock. Before installing the electrics, shut down all supply circuits, switch off mains fuse, secure against being accidentally switched back on and position a visible warning sign. During operation, the board cover and front cover of the internal housing must be mounted.
WARNING Danger of burns/fire due to overload caused by incorrect connection or connecting too many units to a RLS 45 O / RLS 45 K. Connect units in accordance with connection diagram. Observe permissible number of ventilation units per room air control/power unit.
WARNING Danger of electric shock if the 12 V low voltage and 230 V are not disconnected or are insufficiently disconnected. Ensure a safety distance between 230 V and 12 V cables. Ensure minimum distance of 8 mm.
WARNING Danger of electric shock if the connection on the 230 V input of the PP 45 RC units and the RLS 45 O / RLS 45 K controller is incorrect. Ensure a phase balance between all components connected to the ventilation system.
WARNING Danger of electric shock if the RLS 45 O / RLS 45 K control is installed within the protection zone. No IP protection present (IP 00). The room air control may only be installed outside protective zones 0, 1 or 2.

39

8 Installation

WARNING Danger of electric shock if the ventilation units are installed within the protection zone. The units may only be installed in the specified protection zones in accordance with the IP degree of protection. Use PP 45 only outside protection zones 0, 1 and 2. Use PPB 30 O, PPB 30 K only outside of protection zone 0. Use PPB 30 RC only outside of protection zones 0 and 1.
When wiring several unit pairs/ventilation units, always use a deep/double flush-mounted box (flush-mounted box provided by customer).
Strip wires of connection cables sufficiently.
8.7 Connecting room air controls
For RLS 45 O / RLS 45 K controls with 230 V, observe the safety regulations Electrical connection 230 V.
8.7.1 Wired systems An RLS 45 O or RLS 45 K master room air control can have a maximum of 3 further power units and/or slave room air controls of a similar design added to it. A maximum of 4 control units can therefore be deployed in a PP 45 ventilation system.
You can only combine room air controls of the same type (either RLS 45 O or RLS 45 K).
All other room air controls/power units are connected via the RS 485 interface.
If further room air controls are connected, these must be defined as slaves in service mode operating instructions or installation instructions.
The relevant ventilation units are connected to the relevant room air controls/power units. The connection of the ventilation units to an RLS 45 O / RLS 45 K generally takes place on the terminal block of Fan1 or Fan2.

To install the room air control, we always recommend using a deep flush- mounted box. If connecting more than two units, we recommend wiring in a double flush-mounted box or in an additional flush-mounted box. PPB 30 ventilation units are not suitable for use with PP 45 LT power units.
8.7.4 Connecting RLS 45 O RLS 45 O room air control is used to activate PPB 30 O units.
1. Take off frame of room air control.
2. Connect the PPBs according to the wiring diagram appendix. [} 80] The exhaust air function is only possible if a PPB 30 O is connected (service mode setting for unit type = PPB 30 O and number of units = 1).
3. Insert room air control in the flush-mounted box and screw down to flush- mounted box with 2 screws.
4. Fit frame. Ensure that the sensor opening is above the PP 45 HYI (if fitted) and that the frame engages. Commission ventilation system .
8.7.5 Connecting RLS 45 K

8.7.2 Radio-controlled systems Radio controlled systems with RLS 45 K control and PP 45 EO radio module With this unit combination, radio units can be paired with wired devices.
8.7.3 Connections
For combination options Unit overview and connection options [} 34].

RLS 45 K room air control is used to activate PPB 30 O / PPB 30 K units.
1. Take off frame of room air control.
2. Connect thePPB 30 O to the RLS 45 terminals FAN1 and FAN 2. Connect PPB 30 K units to RS 485 bus.

40

8 Installation

Information
· The power supply to the PPB 30 K (+) MUST come from the Fan1 or Fan2 connection. Make
connection according to wiring diagram Connection and wiring diagrams [} 80].
· A combination of PPB30 O and PP 45 units is not permitted at the FAN1 and FAN2 connection terminals of the RLS control.
· No exhaust air function is possible for PPB 30 O units on an RLS 45 K control.
· If a PPB 30 K is running in exhaust air mode, the PP 45 / PPB 30 O units handle the volumetric flow compensation at the fan interface (Fan1/Fan2). It is important that the unit type + quantity are set correctly.
3. Insert room air control in the flush-mounted box and screw down to flush- mounted box with 2 screws.
4. Fit frame. Ensure that the sensor opening is above the PP 45 HYI (if fitted) and that the frame engages.
5. Commissioning ventilation system .

8.8 Installing radio switch (EnOcean)
When radio mode is activated, EnOcean radio components, such as master or slave units or sensors, can be taught-in directly on ventilation
units. For range of radio components Technical data [} 33].

Purely radio- Combination system controlled system

DS 45 RC

RLS 45 K

PP 45 EO

PP 45 RC

max. 6

PP 45 RC

PP 45 RC

PP 45 K

PPB 30 RC

PPB 30 RC PP 45 O

or

max. 3

PPB 30 O / PPB 30 K

Installation location: Do not mount receiver, with internal antenna, on wall side of transmitter.

Purely radio-controlled PP 45 system 1. Simply glue DS 45 RC to installation location
on the wall. Alternatively, the radio switch can also be screwed onto the wall (mounting material provided by customer). 2. Use the “Learn button” to activate teaching-in mode on the ventilation unit. For more detailed information on teaching-in Operating instructions. 3. For basic unit settings, such as “Block Off function” Installation instructions. PushPull combination system with PP 45 EO Extension module PP 45 EO can only be combined with PP 45 RC unit pairs. Wired operation is needed for other unit types. 4. Connect EnOcean extension module to RLS 45 K control (RS485) Connection and wiring diagrams [} 80] 5. Start up ventilation system, activate in EnOcean service mode . PP 45 Act EnOcean actuator With the PP 45 Act EnOcean actuator, radio- controlled PP 45 RC PushPull units can be combined with wired exhaust air units (ECA, ER). Installation similar to light switch installation; can be switched on and off at the touch of a button. For more information Accessories instructions.
8.9 Installing PP 45 HYI humidity sensor in RLS 45 O or RLS 45 K
1. Install room air control as described before.
NOTICE: Unit damage/no function if the humidity sensor is installed incorrectly. Do not bend pins. Insert sensor up to stop in bush.

Commissioning

2. Insert PP 45 HYI humidity sensor at I2C interface Arrow.
3. Fit frame. Make sure it locks into position.
The frame has NO protection against twisting. Ensure that sensor opening (hole in frame) is above the sensor.
4. Start up ventilation system and register humidity sensor in service mode..
For installation and wiring of an external sensor PP 45 / PPB 30 installation and commissioning instructions.
9 Commissioning
Basic settings on the room air control are undertaken in service mode. If connected to RLS 45 K, the commissioning software may also be used.
Switch on ventilation system as follows:
1. Ensure that all ventilation units and system components are connected to the room air controls.
2. Remove warning sign from fuse box and switch on mains fuse. The ventilation units start up in ventilation level 2.
3. Run function test.
4. Set the desired parameter values in Service mode or using the commissioning software.
Basic settings can be made directly on the RLS 45 O or RLS 45 K room air control unit. To do this, select Service mode and set the desired parameter value. Additional information can be found in the online commissioning instructions (download at www.maico-ventilatoren.com). Here you can also download the commissioning software for the RLS 45 K control. This provides you with a wide range of setting parameters for individual system adjustments.

Cycle: selecting parameter

You can

switch

between the

/

sub-menus

by pressing

the button

once.

Flashing operating mode LEDs show in which submenu item you are*/** following chapters.

  • Illuminated ventilation level LEDs indicate the parameter currently set.
    ** For PP 45 RC, the red flashing LED indicates the currently set parameter.

Changing parameter value

Once you Once the para-

have reached meter has

a certain sub- been changed,

/

menu, the the ventilation

parameters level LEDs

can be set flash.

with these

buttons.

Saving parameter value

To save,

The parameter

press the but- value is now

ton for 2

accepted.*/**

seconds.

9.1 Service mode ­ operation

Starting service mode

Press both

buttons for

5 seconds.

Operating mode LED flashes. You are in the 1st submenu (number of unit pairs, ventilation level, etc.) following chapters.

  • The ventilation level LEDs light up permanently again.
    ** On RC units, all 3 LEDs light up and then go out one after another. Parameter value is adopted, service menu is exited.

Exiting service mode

Press both

buttons for

5 seconds.

The unit switches back to the current

42

9 Commissioning

ventilation

mode/ventila-

tion level.

If no button is pressed for 120 seconds

9.2 RLS 45 O service menu

Bold Factory settings LED flashes quickly

in service

mode, service

mode is auto-

matically ex-

ited.

LED flashes slowly

LEDs

Parameters

Set value / Bin- Setting / description ary display*

Device type on RLS

1

(Fan1/Fan2)

2

PP 45 PPB 30 O

The type family, which is connected to the Fan1/Fan2 fan interface, is selected here.

Notice: Only single-type PP 45 or PPB 30 unit combinations are permitted at the fan interface!

Number of device pairs / 1

devices on RLS (Fan1/ 2

Fan2)

3

4

5

1 PP 45 or 1 PPB 30 unit pair 2 PP 45 or 2 PPB 30 unit pairs 3 PP 45 or 3 PPB 30 unit pairs Odd number 3 PP 45 units Odd number 5 PP 45 units

The number of units connected to the fan interface (Fan1/Fan2) is selected here.

Ventilation levels

1

2

Ventilation level “0” possible Ventilation level “0” blocked If ventilation level “0” is set to blocked, the ventilation units cannot be switched off at this control. The units then run with at least ventilation level 1.

  • The service menu items are set according to the 3-digit binary code 111, e.g. the adjuster “5” is displayed as 101 Upper and lower LEDs light up.

Bold Factory settings LED flashes quickly

LED flashes slowly

43

9 Commissioning

LEDs

Parameters

Set value / Bin- Setting / description ary display*

Power units (LTs) or 0 room air controls (RLS) 1
2 3 4 5 6

Operation without further LTs/RLS Operation with 1 LT or RLS Operation with 2 LTs or RLS Operation with 3 LTs or RLS Slave no. 1 Slave no. 2 Slave no. 3

Adjuster for adding further room air controls (RLS) or power units (LTs) to this room air control. Example: Two further RLS (RLS #2 and #3) are connected to RLS #1.

Set value = 2.

Set set value 4 on RLS #2 and set value 5 on RLS #3.

Notice: Only single-type RLS combinations are permitted!

Sensors

0

No sensor

1

1 internal sensor

2

1 internal sensor +

3

1 external sensor

4

1 internal sensor + 2 external

5

sensors

6

1 internal sensor + 3 external

7

sensors

0 internal sensors + 1 external

sensor

0 internal sensors + 2 external

sensors

0 internal sensors +

3 external sensors

Select how many internal and external sensors are connected/combined. The PP 45 HYI internal sensor and the PP 45 HY, PP 45 CO2 and PP 45 VOC external sensors are available.

  • The service menu items are set according to the 3-digit binary code 111, e.g. the adjuster “5” is displayed as 101 Upper and lower LEDs light up.

Bold Factory settings LED flashes quickly

LED flashes slowly

LEDs

Parameters

Set value / Bin- Setting / description ary display*

44

9 Commissioning

ModBus settings

1

2

3

RS 485 inactive ModBus active 9600 Baud
ModBus active 19200 Baud
This adjuster activates the ModBus and sets the baud rate. Notice: When the Modbus interface is active, external sensors/LTs/RLS cannot be connected.

ModBus address

1

2

3

4

5

6

7

Address 10 Address 11 Address 12 Address 13 Address 14 Address 15 Address 16 This adjuster selects the ModBus address.

  • The service menu items are set according to the 3-digit binary code 111, e.g. the adjuster “5” is displayed as 101 Upper and lower LEDs light up.

9.3 RLS 45 K service menu

Bold Factory settings LED flashes quickly

LED flashes slowly

LEDs

Parameters
Device type on RLS (Fan1/Fan2)

Set value / ventilation level
1 2

Setting / description
PP 45 PPB 30 O Here, the type family, which is connected to the Fan1/Fan2 interface, is selected. Notice: Only single-type PP 45 or PPB 30 unit combinations are permitted at the fan interface!

Number of device pairs/ 1

devices on RLS (Fan1/ 2

Fan2)

3

4

5

1 PP 45 or 1 PPB 30 unit pair 2 PP 45 or 2 PPB 30 unit pairs or 3 PP 45 or 3 PPB 30 unit pairs Odd number 3 PP 45 units Odd number 5 PP 45 units
The number of units connected to the fan interface (Fan1/ Fan2) is selected here. Notice: Release/number of

45

9 Commissioning
Ventilation levels
Bold Factory settings LED flashes quickly

PPB 30 K units is taken into account in another sub-menu (PPB 30 K parameters)

1

Ventilation level “0” pos-

2

sible

Ventilation level “0” blocked

If ventilation level “0” is set to

blocked, the ventilation units

cannot be switched off at this

control. The units then run

with at least ventilation level

LED flashes slowly

LEDs

Parameters
Power units (LTs) or room air controls (RLS)

Set value / ventilation level
0 1 2 3 4 5 6

230 VAC input

1

2

3

4

5

6

Setting / description
Operation without further LTs/RLS Operation with 1 LT or RLS Operation with 2 LTs or RLS Operation with 3 LTs or RLS Slave no. 1 Slave no. 2 Slave no. 3
Adjuster for adding further room air controls (RLS) or power units (LTs) to this room air control. Example: Two further RLS (RLS #2 and #3) are connected to RLS #1. Set value = 2. Set set value 4 on RLS #2 and set value 5 on RLS #3. Notice: Only single-type RLS combinations are permitted!
Sleep mode Intermittent ventilation Safety shutdown Supply air operation without overrun Supply air mode with overrun time of 6 min. Supply air mode with overrun time of 15 min.
For setting an additional function. This can be activated with a button or switch at the 230 V input.

46

9 Commissioning
Bold Factory settings LED flashes quickly

LEDs

Parameters Sensors

EnOcean

LED flashes slowly

Set value / ventilation level 0 1 2 3 4 5 6 7
0 1

Setting / description
No sensor 1 internal sensor 1 internal sensor + 1 external sensor 1 internal sensor + 2 external sensors 1 internal sensor + 3 external sensors 0 internal sensors + 1 external sensor 0 internal sensors + 2 external sensors 0 internal sensors + 3 external sensors
Select how many internal and external sensors are connected/combined. The PP 45 HYI internal sensor and the PP 45 HY, PP 45 CO2 and PP 45 VOC external sensors are available.
EnOcean module not present EnOcean module present This adjuster enables the use of the EnOcean expansion module (PP 45 EO).

Bold Factory settings LED flashes quickly

LED flashes slowly

47

9 Commissioning
LEDs

Parameters Not assigned

Set value / ventilation level

Setting / description

PPB 30 K

0

1

2

3

ModBus settings

1

2

3

ModBus address

1

2

3

4

5

6

7

No PPB 30 K 1 PPB 30 K 2 PPB 30 K 3 PPB 30 K
State the number of PPB 30 K units connected to the RS 485 interface here.
RS-485 inactive ModBus active 9600 Baud ModBus active 19200 Baud This adjuster activates the ModBus and sets the baud rate. Notice: When the Modbus interface is active, PPB 30 K or external sensors/LTs/RLS cannot be connected.
Address 10 Address 11 Address 12 Address 13 Address 14 Address 15 Address 16
The ModBus address is selected with this adjuster.

48

9 Commissioning
9.4 PPB 30 RC service menu
Bold Factory settings LED flashes quickly

LED flashes slowly

PPB 30 RC LEDs

Parameters

The orange Operating

operating

modes

mode LED

flashes 1x per

cycle

Set value Setting / description

1

Automatic operation (red LED 1x)

2

system operation (red LED 2x)

Two operating modes can be selected here. Automatic operation: Unit usually works autonomously according to internal sensor. System operation: The unit usually works according to the controller specifications. For more detailed description Operating instructions.

The orange Sensor

0

inactive (red LED OFF)

operating

1

active 40 % – 70 % r. h. (red LED 1x)

mode LED

2

active 45 % – 80 % r. h. (red LED 2x)

flashes 2x per cycle

The limit values of the integrated humidity sensor can be set or deactivated here.

The orange Ventilation

0

operating

levels

1

mode LED

flashes 3x per

cycle

Ventilation levels Off possible (red LED OFF) Ventilation level Off blocked (red LED 1x)
With the ventilation level “0” blocked setting, the ventilation units cannot be switched off on this control. The units then run with at least ventilation level 1.

The orange Selection of

1

operating

auto/manual de-

mode LED humidification 2

flashes 4x per function

cycle

3

4

Exhaust air mode Automatic / Manual exhaust air mode (red LED 1x) Automatic exhaust air mode / Manual intensive ventilation (red LED 2x) Automatic intensive ventilation / Manual exhaust mode (red LED 3x) Automatic intensive ventilation / Manual intensive ventilation (red LED 4x) The dehumidification function for the sensor (Auto) and for the button (Manual) can be set here.

49

9 Commissioning
Bold Factory settings LED flashes quickly

LED flashes slowly

PPB 30 RC LEDs

Parameters

The blue oper- Duration of ating mode intermittent LED flashes ventilation/ 1x per cycle ventilation level

Set value
1 2 3

Setting / description
5 minutes (red LED 1x) 10 minutes (red LED 2x) 30 minutes (red LED 3x)
Parameters for the duration of the manual dehumidification function (level 5) and the duration of the ventilation level when overriding demand-driven operation are set here (factory setting 10 minutes).

The blue oper- Sleep function 1

ating mode

2

LED flashes

3

2x per cycle

30 minutes (red LED 1x) 60 minutes (red LED 2x) 90 minutes (red LED 3x) The duration of the sleep function (level 0) is parameterised here (factory setting 60 minutes).

The blue oper- Filter runtime 1

ating mode

2

LED flashes

3

3x per cycle

4

2 months (red LED 1x) 3 months (red LED 2x) 6 months (red LED 3x) Reset filter runtime (red LED 4x) .The filter runtime is parameterised here (factory setting 6 months).

The blue oper- Single-room 1 ating mode ventilation unit 2
LED flashes
4x per cycle

Operation in pairs (red LED 1x) single-room ventilation unit (red LED 2x)
If there are reception problems with the slave or master device, the PPB 30 RC unit can be enabled as a single-room ventilation unit.

Spare parts

10 Spare parts
Important for orders: When ordering spare parts, state the article number as well as the unit type and serial number of the ventilation unit.