VDLPOWER SC0101 Solar Panel User Manual

June 16, 2024
VDLPOWER

VDLPOWER Logo SOLAR PANEL
100W
User’s Manual VDLPOWER SC0101 Solar PanelModel: SC0101

For more information,

please visit our website or E-mail: Warranty Cardis inside
Wed: www.vdlpower.com
E-mail: [email protected]
E-mail: [email protected]

VDLPOWER SC0101 Solar Panel - QR

How To Charge

VDLPOWER SC0101 Solar Panel - Charge

Adjust Angle

VDLPOWER SC0101 Solar Panel - Adjust Angle

Technical Details:

Model: SC0101
Peak Power(Pm): 100W
Cell Type: Monocrystalline silicon
Solar Cell Lamination: ETFE
Cell Efficiency: Up to 23.5%
Voltage at Max Power(Vmp): 20V
Current at Max Power(Imp): 5A
Operating Temperature: -10    ~65
Best Working Temperature: 25
Folding Number: 2
Dimension(unfolded): 5901143mm/23.245.0 inch
Dimension(folded): 590559mm/23.222.0 inch
Weight: 4.5kg/9.9 lb

Safety Tips:

  • Do not bend the solar panel po notsoak the solar panel into water or any other liquid
  • Do not use or store this solar panel near fire or heater
  • Do not scratch the solar panel with sharp objects
  • Do not dissemble the solar panel by yourself
  • Do not put corrosive substance on this solar panel
  • Ensure shade from trees, buildings, and any other obstructions do not block sunlight while using the panels
  • Do not use this product as a children’s toy
  • Please note that the solar panel may be damaged by falling or impact
  • During recharging. keep your portable power station away from heat and direct sunlight to extend its life $pan

VDLPOWER SC0101 Solar Panel - Icon

FAQ(Frequently Asked Questions)

Q: The compatibility of the solar panel. ripe:
To contemn the solar panel’s 0ompatty with 3d-party devices, please consult the seller,
Q. What factors may affect the solar conversion rate?
The weather condition
2. Working environment temperature
3. The angle from the panels to sunlight
Q How to decide the number of panels required to recharge?
The output power of solar panels should fit the recommended voltage
2 The max open circuit voltage is not able to exceed in the max input voltage of power station
3 The gross output current of solar panels should be between the recommended working voltage
when using multiple solar panels in series or parallel, please make sure that the accumulated maximum voltage and current of the solar panels does not exceed in the maximum voltage and current of the power station.

Customize your carefree After-sales service

VDLPOWER SC0101 Solar Panel - Icon 1

If there is a problem with the product within 12 months from the order date, the same new product will be replaced promptly after confirmation. In addition, for members of VDL’s official online store, the usual 12-month product warranty will be automatically extended to 24 months.
※ VDL Official Store Member
How can I join?
How to use:
Step1: Please fill in warranty card.
Step2: Please take the warranty card picture
Step3: Please email the picture to: [email protected]

Warranty Card

This document promises to perform free repair according to the following warranty provisions if a failure occurs within the following period from the date of purchase. pod oleo Product name / Product model:
Product nare/ Product model;

※ Date of purchase  Year     Month     Day _ .a Ow| Warranty period From date of purchase: 12 months fee0fro4| SN No.
---|---|---
User Info Llf| Name ※ Email: Telephone
Order Info Ord if| Amazon user ID: ※ Order number:

SN number on the product
Caution: ※Please be sure to fill in the marked fields and hand them over. If you do not fill in, you may not receive free repair.

Warranty Policies in y Polii

  1. If the product breaks down or is damaged in normal use according to the precautionary statements   such as the instruction manual and the label attached to the main unit, we will repair or replace it   free of charge.

  2. If you want to receive free repair due to malfunction within the warranty period, please contact the   VDL Service Center ( [email protected] ).

  3. If you are unable to request repairs from Amazon, which is included in this warranty, due to a move   or gift, please save your Amazon order number.

  4. Even within the warranty period, repairs will be charged in the following cases:
    ① Failure or damage due to mistakes in use, improper repair, modification, etc.
    ② Failure or damage due to dropping after purchase
    ③ Breakdown and damage due to fire, earthquake, and other natural disasters
    ④ Failure or damage when used for purposes other than general household use(for example, long-term use for business use)
    ⑤ Failure or damage due to movement, transportation or contact with furniture and fixtures after purchase
    ⑥ If this document is not presented

  5. This document is valid only in USA.

  6. This manual will not be reissued, so please keep it in a safe place so that it will not be lost.

How to Return/Replace/Repair

  • Please fill in warranty card & find the SN number on the product;
  • Contact our email: [email protected]
  • Send defective products to our local warehouse.

VDLPOWER Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VDLPOWER User Manuals

Related Manuals