MAICO BK 20 Electric External Shutters Instruction Manual

August 5, 2024
MAICO

MAICO BK 20 Electric External Shutters

Product Usage Instructions

Safety Precautions
Before using the product, ensure to follow these safety guidelines:

  • Turn off the mains fuse and secure it against reconnection.
  • Attach a warning sign to indicate that work is being done.

Electrical Connection

Follow these steps for the electrical connection:

  1. Disconnect the mains fuse and secure it against reconnection.

Start-up Procedure
Initiate the start-up process by:

  1. Switch on the mains fuse and remove the warning sign.

Cleaning
Maintain cleanliness by periodically cleaning the product.

Disassembly and Environmentally Friendly Disposal
If disassembly is required, it should only be carried out by a qualified electrician to ensure safety and proper disposal.

Installation instructions for MK,BK electric external shutters

NOTE
Please read the instructions carefully before installing and using for the first time.

Follow the instructions.
Pass these instructions on to the owner for safekeeping.

Unit Overview

1| External shutter: MK.. with servomotor

BK.. with bi-metal drive

---|---
2| Power cable, pre-wired
3| Empty duct
4| Flyscreen
T| Rating plate

Specialist installer qualifications

Installation may only be carried out by trained specialists who have the necessary knowledge and experience in ventilation engineering. The unit must be connected in accordance with the national technical approval.
Only a qualified electrician is permitted to work on the electrics. You are deemed a qualified electrician if you are familiar with the relevant standards and guidelines, can competently and safely connect units to an electrical power supply in line with the Wiring diagrams and are able to recog-nise and avoid risks and dangers associated with electricity on the basis of your technical training and experience.

Scope of delivery

External shutter, fly screen, empty duct and these installation and operating instructions.

Intended use
Electric external shutters as shutters for ventilation ducts, wall sleeves, etc. For combination with EN/ENR fans, for example. They are attached to exterior walls and serve as weather protection or a cold air barrier when the fan is switched off.
These external shutters open/close when a fan is switched on/off, BK.. external shutters with bi-metal drive open/close with a delay.
MK..S external shutters are equipped with a limit switch that closes a control contact when the shutter is open. This is used, for example, to con-trol an exhaust shutter.
Use is only permissible with:

  • a permanent installation, mounted on an exterior wall with sufficient load-bearing capacity.
  • installation using suitable mounting material.
  • vertical installation position with the Maico lettering at the bottom right.
  • installation complete. The external shutter must not be dismantled.
    These external shutters are only intended for domestic use and similar purposes. Any other use or use beyond this is considered improper use.

Safety instructions

The external shutter must not be used in thefollowing situations under any circumstances.

DANGER Risk of combustion/fire from flammable materials, liquids or gases in the vicinity of the unit.
Do not place any flammable materials, liquids or gases near the unit, which may ignite in the event of heat or sparks and catch fire. DANGER Explosion hazard due to gases and dust.
Explosive gases and dust may ignite and cause serious explosions or fire.
Never use unit in an explosive atmosphere (risk of explosion).

WARNING Risk to health from chemicals or aggressive gases/vapours.
Chemicals or aggressive gases/vapours may harm health, especially if they are distributed throughout the rooms by the unit.
Never use the unit as a duct shutter for chemicals or aggressive gases/vapours.

NOTICE Damage to unit due to grease and oil vapours from range hoods.
Grease and oil vapours from range hoods may contaminate the unit and reduce efficiency. Never use external shutter in combination with range hoods with exhaust air mode.

DANGER Risks for children and people with reduced physical, sensory or mental capabilities or a lack of knowledge.
Unit may only be installed, commissioned, cleaned and maintained by persons who can safely recognise and avoid the risks associated with this work.

WARNING Risk of injury due to suction effect and rotating impeller of a connected fan.
Hair, clothing, jewellery etc. may be pulled into the unit if you get too close to it.
During operation, always keep far enough away to prevent this from happening.

WARNING Risk of injury due to spark formation if foreign bodies are inserted into the unit.
Do not insert any objects in the unit.

NOTICE An external shutter that is not installed correctly may result in non-intended operation or impermissible operation. Operation is only permitted if installed in the correct installation position (Maico logo at bottom right).

WARNING

  • Risk of injury in entrance areas when ice forms due to falling icicles. Never install the shutter above entrance areas that are not covered.

  • Risk of injury and health risk in the event of changes or modifications or if components which are not permitted are used.
    The unit may only be operated with original com-ponents. Changes and modifications to the units are not permitted and release the manufacturer from any guarantee obligations and liability, e. g. if the housing is drilled at a point which is not permitted.

  • Risk of injury when working at heights.
    Use appropriate climbing aids (ladders). Stability should be ensured, if necessary have the ladders steadied by a 2nd person.
    Ensure that you are standing securely and cannot lose your balance and that there is no one under the unit.

NOTICE Depending on type, sound power level up to 66 dB(A).
When planning, take into account sound insulation at the installation site.

DANGER Risk of death from carbon monoxide when operating with air- ventilated fireplaces.
The maximum permitted pressure difference per residential unit is 4 Pa. The consent of a profes-sional chimney sweep is needed in all cases. Ensure sufficient supply air intake during opera-tion with an air-ventilated fireplace.

DANGER Risk of electric shock if oper-ated with a damaged external shutter.
Only operate the external shutter when it is completely installed.
Do not commission a damaged unit.

DANGER Danger if the relevant regula-tions for electrical installations are not observed.
Before installing the electrics, shut down all sup-ply circuits, deactivate the mains fuse and secure it so it cannot be switched back on. Attach a warning sign in a clearly visible place.
Be sure to observe the relevant regulations for electrical installation; e.g. DIN EN 50110-1. In Germany, particularly observe VDE 0100, with the corresponding sections.
A mains isolation device with contact openings of at least 3 mm at each pole is mandatory.
Only connect unit to permanently wired electrical installation and with NYM-O or NYM-J cables, depending on the unit variant, 3 x 1.5 mm² or 5 x 1.5 mm².

Units may only be operated using the voltage and frequency shown on the rating plate.
The degree of protection stated on the rating plate is only guaranteed if installation is undertaken correctly and if the connection cable is properly attached.
Unit may be energized even when at a standstill and may be switched on automatically by sensors, such as for time delay or humidity etc. Maintenance and fault finding only permissible when carried out by qualified electricians

CAUTION when handling packaging materials.
Observe applicable safety and accident prevention regulations.
Store packaging material out of the reach of chil-dren (risk of suffocation due to swallowing).

Product information
The external shutter is switched with a component to be provided by the customer. Can be switched on/off e.g. via on/off switch, TH thermo-stat, TRE…S 5-step transformer or a FS 4 step switch → Accessories.

Technical data

Rated voltage 230 V
Power frequency 50 Hz
Nominal power MK.. 3 W, BK.. 25 W
Rated current MK.. 0.015 A,

BK.. 0.01 A

Starting current| BK.. 1.8 A – 1 sec
Degree of protection| IP 55
Protection class| II (without PE con- ductor)
---|---
Pressure loss| 11 Pa
Ambient and airstream temperature| max. +40 °C.
Storage temperature| -20 to +60 °C, Store unit only in a dry place

Nominal sizes, dimensions [A]…[D], in [mm]

| N| A| B| C| D
---|---|---|---|---|---
MK 20| 200| 325| 218| 275| 83
MK 25| 250| 370| 262| 320| 105.5
MK 31| 315| 430| 320| 380| 135.5
BK 20| 200| 325| 218| 275| 83
BK 25| 250| 370| 262| 320| 105.5
BK 31| 315| 430| 320| 380| 135.5

Installation

NOTICE External shutter does not close correctly if it is installed under tension.
In order to guarantee the shutter function, only mount the external shutter on a flat surface. Allow sufficient space to the wall or ceiling.

  1. Switch off mains fuse, secure against being accidentally switched back on and position a warning sign.

  2. Ensure a level surface in the area of the installation site.

  3. Install wall sleeve/ventilation channel matching the nominal diameter in the exterior wall.

  4. Attach the enclosed empty duct [3] (for the connection cable) to the exterior wall.
    Note the position of the connection cable in the rear panel of the housing.

  5. Align the external shutter and mark the posi-tion of the 4 holes. For spacing Technical data [} 8].

  6. Drill the 4 fixing holes and insert the dowels. Suitable mounting material is to be provided by the customer.

  7. Press the fly screen [4] onto the studs on the rear wall of the external shutters.
    NOTICE Shutter function not guaranteed if installed incorrectly.
    Make sure that the cable [2] is routed tightly out of the external shutter and that it does not jam the inner slider.

  8. Insert the cable [2] on the exterior wall through the empty duct [3] and tighten slightly.

  9. Screw the external shutter firmly to the wall with 4 screws. Suitable mounting material is to be provided by the customer

Electrical connection

NOTICE Risk of damage to unit in the event of short circuits.

Insulate any unnecessary cable cores.

  • Always note the relevant specifications for elec-trical installations and when fitting equipment. In Germany, observe DIN VDE 0100 and the cor-responding parts in particular.
  • The connection cable between the external shutter and the fan terminal box must be firmly routed.
  • Only connect the external shutter in parallel to the fan.
  • Do not connect the external shutter to a regulated voltage source.
  • Design in accordance with protection class II.
    1. Switch off mains fuse, secure against being accidentally switched back on and position a warning sign.
    2. Make electrical connections according to cir-cuit diagrams (Circuit diagrams (connection examples) [} 15]).

Commissioning

  1. Check compliance with the technical data on the → rating plate.
  2. Ensure that the air can flow freely.
  3. Switch on mains fuse, remove warning sign.
  4. Run function test. Check the correct closing and opening function.

Cleaning

Cleaning is done with a dry cloth if necessary –frequency depends on environmental conditions and expected impairments. Do not use aggress-ive, harmful or easily flammable cleaning agents. To clean, swing the lamellae of the external shut-ter upwards.
The external shutter is maintenance-free

Fault rectification
Fault finding and repairs may only be car-ried out by qualified electricians.

Malfunction Cause, measure
External shutter does not open or close. No mains voltage. Check whether the

mains fuse has failed. Switch on if necessary.

Dismantling and environmentally sound disposal
Dismantling may only be undertaken by a qualified electrician.

The unit and the packaging contain parts that can be recycled, and should not end up in the domestic waste. Dispose of the packaging material and the unit in an environmentally friendly way, in compliance with the regulations valid in the country where you are.

Company information
© Maico Elektroapparate-Fabrik GmbH. Translation of the original German operating instruc-tions. Misprints, errors and technical changes are reserved.

Circuit diagrams

FAQ

Q: What is the intended use of the product?
A: The product is designed as electric external shutters for ventilation ducts and wall sleeves, providing weather protection and cold air barrier functions.

Q: Can the external shutters be used for commercial purposes?
A: No, the external shutters are intended for domestic use and similar purposes. Commercial use is considered improper.

Q: What safety precautions should be followed during installation?
A: Ensure to disconnect the mains fuse, secure it against reconnection, and display a warning sign indicating ongoing work.

Maico Elektroapparate-Fabrik GmbH ISteinbeisstr. 20 I 78056 Villingen- Schwenningen I Germany I www.maico-ventilatoren.com I Service +49 7720 6940 Iinfo@maico.de

www.maico-ventilatoren.com