MAICO AS 20 Ex Axial Wall Fan Instructions

August 20, 2024
MAICO

MAICO AS 20 Ex Axial Wall

Product Information

Specifications

  • Model Numbers: AS 20 Ex, AS 25 Ex, AS 30 Ex, AS 35 Ex, AS 40 Ex, AS 45 Ex, AS 50 Ex, AS 65 Ex, AS 71 Ex
  • Manufacturer: Maico Ventilatoren
  • Website: www.maico-ventilatoren.com

Product Usage Instructions

Safety Precautions
Ensure to follow all safety instructions provided in the manual to prevent any potential risks or hazards.

Installation

  1. Secure the shutter including the protective grille to the wall using 4 screws.

Cleaning
The shutter does not require any specific maintenance and is considered maintenance-free.

Dismantling and Disposal

  1. Separate the components based on material groups for proper disposal.

Frequently Asked Questions (FAQ)

  • Q: Is it necessary to earth the shutter to avoid electrostatic discharge?
    A: Yes, it is crucial to earth the shutter to prevent any potential electrostatic discharge hazards.

  • Q: How should I dispose of the shutter components?
    A: It is recommended to separate the components based on material groups for environmentally friendly disposal.

Original installation instructions for AS Ex shutter

AS 20 Ex, AS 25 Ex
AS 30 Ex, AS 35 Ex
AS 40 Ex, AS 45 Ex
AS 50 Ex, AS 65 Ex
AS 71 Ex
www.maico-ventilatoren.com

Verschlussklappe AS Ex AS Ex shutter
Violet de Fermeture AS Ex

Installation instructions for shutters
NOTE
Please read the instructions carefully before installing and using for the first time.
Follow the instructions.
Pass these instructions on to the owner for safe-keeping.

Safety

WARNING Risk of injury in entrance areas when ice forms due to falling icicles. Never install the shutter above entrance areas that are not covered.
WARNING Risk of injury when working at heights.
Use appropriate climbing aids (ladders). Stability should be ensured, if necessary have the ladders steadied by a 2nd person.
Ensure that you are standing securely and cannot lose your balance and that there is no one under the unit.

DANGER Explosion hazard due to electrostatic discharge. Earth the shutter to avoid electrostatic discharge.

CAUTION when handling packaging materials.
Observe applicable safety and accident prevention regulations.
Store packaging material out of the reach of children (risk of suffocation due to swallowing).

Scope of delivery

Shutter, protective grille, these installation and operating instructions.

Qualification of installation cleaning and maintenance staff

Installation, commissioning, cleaning and maintenance may only be undertaken by qualified electricians trained and authorised in explo-sion protection (see also Directive 1999/92/EC, Appendix II 2.8). These are qualified persons ac- cording to BetrSichV Section 2 (6) in conjunction with Appendix 2 Section 3, No. 3.3, who are also qualified electricians as defined by DGUV regulation 3, Section 2 (3). Further provisions of other national laws must be taken into account. Installation, commissioning, cleaning and main-tenance may only be undertaken by qualified electricians trained and authorised in explo-sion protection in accordance with Directive 1999/92/EC, Appendix II 2.8. These are qualified persons in accordance with the above-mentioned directive, that are also trained as qualified electricians. Further provisions of other national laws must be taken into account.

Intended use

Self-opening/closing shutters for air extraction from the potentially explosive atmospheres of zones 1, 2 and 21, 22. These also serve as weather protection and cold air barriers. With en-closed galvanized protective grille.
From size 65 with central bar to increase shutter stability.
Operation is only permitted with:

  • a permanent installation, mounted on a wall with sufficient load-bearing capacity.
  • installation using suitable mounting material.
  • a vertical installation position.
  • installation using protective grille with free air in-let or outlet for a fan.

 Technical data

For more technical data → Internet, maico-ventil-atoren.com. Nominal sizes [A], dimensions [B]…[D] Dimensions in [mm]

| A| B| C| D
---|---|---|---|---
AS 20 Ex| 242| 182| 21| 209
AS 25 Ex| 294| 232| 26| 258
AS 30 Ex| 346| 276| 25| 309
AS 35 Ex| 396| 311| 25| 359
AS 40 Ex| 462| 366| 26| 422
AS 45 Ex| 501| 396| 30| 462
AS 50 Ex| 548| 443| 30| 505
AS 65 Ex| 696| 628| 30| 655
AS 71 Ex| 760| 692| 40| 720

 Ambient/operating conditions

Ambient temperature -30 °C to +60 °C.

 Installation

NOTICE Shutter does not close correctly if it is installed under tension.
In order to guarantee the shutter function, only mount the shutter on a flat surface.
Allow sufficient space to the wall or ceiling.

  1.  Open and align the lamellae of the shutter.
  2.  Mark the 4 drilling positions of the fixing holes, drill and insert the dowels.
  3.  Place the protective grille on the back of the shutter.
  4.  Screw the shutter including the protective grille to the wall with 4 screws.
  5.  To prevent electrostatic charging and thus en-sure proper functioning, earth the shutter prop-erly in accordance with the applicable VDE guidelines.
  6.  Run function test.

Cleaning

Cleaning is done with a dry cloth if necessary –frequency depends on environmental conditions and expected impairments.
To clean, swing the lamellae of the shutter up-wards. Do not use aggressive, harmful or easily flammable cleaning agents. The shutter is maintenance-free.

 Dismantling, environmentally- sound disposal

Dismantling may only be undertaken by a trained specialist. Do not dispose of old units in the normal house-hold waste. Proper disposal avoids detrimental impact on people and the environment and allows valuable raw materials to be reused with the least amount of environmental impact.

  1.  Separate the components according to material groups.
  2.  Dispose of the components and packaging materials (cardboard, filling materials, plastics) via appropriate recycling systems or recycling centres.
  3.  Observe the respective country-specific and local regulations.

Company information
© Maico Elektro apparate-Fabrik GmbH. Translation of the original operating instructions. Mis-prints, errors and technical changes are reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals