Elko EP RFSAI-62B-SL Switch Unit with Input For External Button Instruction Manual
- June 11, 2024
- ELKO ep
Table of Contents
- RFSAI-62B-SL Switch Unit with Input For External Button
- Characteristics
- Assembly
- Connection
- Screwless terminals
- Radio frequency signal penetration through various construction materials
- Indication, manual control
- Compatibility
- Channel selection
- RFSAI-62B-SL, RFSAI-61B-SL, RFSAI-11B-SL
- Description of button
- Programming
- Function switch on
- Programming
- Function switch off
- Programming
- Function impulse relay
- Programming
- Function delayed off
- Function delayed on
- Programming with RF control units
- Delete actuator
- Selecting the memory function
- Technical parameters
- Warning
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RFSAI-62B-SL Switch Unit with Input For External Button
RFSAI-62B-SL, RFSAI-61B-SL, RFSAI-11B-SL
Switch unit with input for external button
Characteristics
- The switching component with one/two output relays is used to control appliances and lights. Switches/buttons connected to the wiring can be used for control.
- They can be combined with Detectors, Controllers or iNELS RF Control System Components.
- The BOX version off ers installation directly in the installation box, ceiling or cover of the controlled appliance. Easy installation thanks to screwless terminals.
- It allows the connection of switched loads with a total sum of 8 A (2000 W).
- Functions: for RFSAI 61B-SL and RFSAI 62B-SL – pushbutton, impulse relay and time functions of delayed start or return with time setting 2 s-60 min. Any function can be assigned to each output relay. For RFSAI-11B-SL, the button has a fi xed function – ON / OFF.
- The external button is assigned in the same way as the wireless one.
- Each of the outputs can be controlled by up to 12/12 channels (1-channel represents one button on the controller). Up to 25 channels for RFSAI-61B-SL and RFSAI-11B-SL.
- The programming button on the component also serves as a manual output control.
- Possibility to set the output status memory in case of failure and subsequent power recovery.
- The elements of the repeater can be set for the components via the RFAF / USB service device, PC, application.
- Range up to 200 m (outdoors), in case of insufficient signal between the controller and the device, use the RFRP-20 signal repeater or component with the RFIO2 protocol that support this function.
- Communication with bidirectional RFIO2 protocol.
- The contact material of the AgSnO2 relay enables switching of light ballasts.
Assembly
mounting in an installation box /
(even under the existing button / switch)
Connection
Screwless terminals
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
Radio frequency signal penetration through various construction materials
| |
|
|
---|---|---|---|---
60 – 90 %
|
80 – 95 %
|
20 – 60 %
|
0 – 10 %
|
80- 90 %
brick walls
|
wooden structures with plaster boards
|
reinforced concrete
|
metal partitions
|
common glass
Indication, manual control
1. LED / PROG button
• LED green V1 – device status indication for output 1
• LED red V2 – device status indication for output 2.
Indicators of memory function:
On – LED blinks x 3.
Off – The LED lights up once for a long time.
• Manual control is performed by pressing the PROG button for<1s.
• Programming is performed by pressing the PROG button for 3-5s.
2. Terminal block – connection for external button
3. Terminal block – connecting the neutral conductor
4. Terminal block – load connection with the sum of the total
current 8A (eg V1=6A, V2=2A)
5. Terminal block for connecting the phase conductor
In the programming and operating mode, the LED on the
component lights up at the same time each time the button is
pressed – this indicates the incoming command.
- RFSAI-61B-SL: one output contact, status indication by red LED
Use a suitable tool (paper clip, screwdriver) to push on the control pin. The batteries are raised and the programming button is released.
After removing the control flaps, the programming button is accessible
The programming button is operated with a suitable thin tool.
Compatibility
The device can be combined with all system components, controls and devices
of iNELS RF Control and iNELS RF Control2.
The detector can be assigned an iNELS RF Control2 (RFIO2) communication
protocol.
Channel selection
Channel selection (RFSAI-62B-SL) is done by pressing the PROG buttons for
1-3s.
RFSAI-61B-SL: press for more than 1 second.
After button release, LED is fl ashing indicating the output channel: red (1)
or
green (2). All other signals are indicated by corresponding color of LED for
each
channel.
RFSAI-62B-SL, RFSAI-61B-SL, RFSAI-11B-SL
Switch unit with input for external button
Functions and programming with RF transmitters
Function button
Description of button
The output contact will be closed by pressing the button and opened by
releasing
the button.
For the correct execution of individual commands (press = closing / releasing
the
button = opening), the time delay between these commands must be a min of .
1s (press – delay 1s – release).
Programming
Press of programming button
on receiver RFSAI-62B for 3-5 s
(RFSAI-61B-SL: press for more than
1 s) will activate receiver RFSAI-62B
into programming mode. LED is
flashing in 1s interval.
Select and press one button
on wireless switch, to this button
will be assigned function
Button.
Press of programming button
on receiver RFSAI-62B shorter
then 1 second will fi nish programming
mode. The LED
lights up according to the preset
memory function.
Function switch on
Description of switch on
The output contact will be closed by pressing the button.
Programming
Press of programming button on
receiver RFSAI-62B for 3-5 s (RFSAI-
11B-SL: press for more than 1s)
will activate receiver RFSAI-62B
into programming mode. LED is
flashing in 1s interval.
Two presses of your selected
button on the RF transmitter
assigns the function switch on
(must be a lapse of 1s between
individual presses).
Press of programming button
on receiver RFSAI-62B shorter
then 1 second will finish programming
mode. The LED
lights up according to the preset
memory function.
Function switch off
The output contact will be opened by pressing the button.
Programming
Press of programming button on
receiver RFSAI-62B for 3-5 s (RFSAI-
61B-SL: press for more than 1
s) will activate receiver RFSAI-62B
into programming mode. LED is
flashing in 1s interval.
Three presses of your selected
button on the RF transmitter
assigns the function switch off
(must be a lapse of 1s between
individual presses).
Press of programming button
on receiver RFSAI-62B shorter
then 1 second will fi nish programming
mode. The LED
lights up according to the preset
memory function.
Function impulse relay
Description of impulse relay
The output contact will be switched to the opposite position by each press of the button. If the contact was closed, it will be opened and vice versa.
Programming
Press of programming button
on receiver RFSAI-62B for 3-5 s
(RFSAI-61B-SL: press for more than1 s) will activate receiver RFSAI-62B into
programming mode. LED is flashing in 1s interval.
Four presses of your selected
button on the RF transmitter assigns
the function impulse relay
(must be a lapse of 1s between
individual presses).
Press of programming button
on receiver RFSAI-62B shorter then 1 second will finish programming
mode. The LED lights up according to the preset
memory function.
Function delayed off
Description of delayed off
The output contact will be closed by pressing the button and opened after the set time interval has elapsed.
Press of programming button on
receiver RFSAI-62B for 3-5 s (RFSAI-
61B-SL: press for more than 1
s) will activate receiver RFSAI-62B
into programming mode. LED is
flashing in 1s interval.
Assignment of the delayed off
function is performed by fi ve
presses of the selected button
on the RF transmitter (must be
a lapse of 1s between individual presses).
Press of programming button
longer then 5 seconds, will
activate actuator into timing
mode. LED fl ashs 2x in each
1s interval. Upon releasing the
button, the delayed return
time starts counting.
After the desired time has
elapsed (range of 2s…60min),
the timing mode ends by
pressing the button on the
RF transmitter, to which the delayed return function is
assigned. This stores the set time interval into the actuator
memory.
Press of programming button
on receiver RFSAI-62B shorter
then 1 second will finish programming
mode. The LED lights
up according to the pre-set memory function.
Function delayed on
Description of delayed on
The output contact will be opened by pressing the button and closed after the
set
time interval has elapsed.
Press of programming button on
receiver RFSAI-62B for 3-5 s (RFSAI-
61B-SL: press for more than
1s) will activate receiver RFSAI-
62B into programming mode.
LED is flashing in 1s interval.
Assignment of the delayed on
function is performed by six
presses of the selected button
on the RF transmitter (must be
a lapse of 1s between individual presses).
Press of programming button
longer then 5 seconds, will
activate actuator into timing
mode. LED fl ashs 2x in each
1s interval. Upon releasing the
button, the delayed return
time starts counting.
After the desired time has
elapsed (range of 2s…60min),
the timing mode ends by
pressing the button on the
RF transmitter, to which the
delayed return function is
assigned. This stores the set
time interval into the actuator memory.
Press of programming button
on receiver RFSAI-62B shorter
then 1 second will fi nish programming
mode. The LED lights
up according to the pre-set memory function.
Programming with RF control units
Addresses listed on the front side of the actuator are used for programming
and controlling the actuator and individual RF channels by control units.
Delete actuator
By pressing the programming button on the actuator for 8 seconds
(RFSAI-61B-SL: press for 5 second), deletion of one transmitter
activates. LED flashs 4x in each 1s interval.
Pressing the required button on the transmitter deletes it from
the actuator’s memory.
To confirm deletion, the LED will confirm with a fl ash long and
the component returns to the operating mode. The memory
status is not indicated.
Deletion does not affect the pre-set memory function.
By pressing the programming button on the actuator for 11 seconds
(RFSAI-61B-SL: press for more than 8 second), deletion occurs
of the actuator’s entire memory. LED flashs 4x in each 1s interval.
The actuator goes into the programming mode, the LED fl ashes
in 0.5s intervals (max. 4 min.).
You can return to the operating mode by pressing the Prog button
for less than 1s. The LED lights up according to the pre-set memory
function and the component returns to the operating mode.
Deletion does not affect the pre-set memory function.
Selecting the memory function
Press of programming button on receiver RFSAI-62B for 3-5 second
(RFSAI-61B-SL: press for 1 second) will activate receiver RFSAI-
62B into programming mode. LED is fl ashing in 1s interval.
Pressing the programming button on the RFSAI-62B receiver for
less than 1 second will fi nish the programming mode, this will reverse
the memory function. The LED lights up according to the
current pre-set memory function. The set memory function is
saved.
Every other change is made in the same way.
-
Memory function on:
– For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change. -
For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.
-
Memory function off:
When the power supply is reconnected, the relay remains off.
The external button RFSAI-62B-SL is programmed in the same way as for
wireless.
RFSAI-11B-SL it is not programmed, it has a fixed function.
Technical parameters
Supply voltage: | 230 V AC |
---|---|
Supply voltage frequency: | 50-60 Hz |
Apparent input: |
7 VA / cos φ = 0.1
Dissipated power:| 0.7 W
Supply voltage tolerance:| =+10 %; -15 %
Output|
Number of contacts:|
1x switching 2x switching
Rated current:| 8 A / AC1
Switching power:| 2000 VA / AC1
Peak current:| 10 A / <3 s
Switching voltage:| 250 V AC1
Mechanical service life:| 1×107
Electrical service life (AC1):| 1×105
Control|
Wireless:|
25-channels – 2 x 12-channels
Number of functions:| 1,6,6
Communication protocol:| RFIO2
Frequency:|
866–922 MHz (for more information see p. 74)/ 866–922 MHz (см. стр. 74)
Repeater function:| yes
Manual control:|
button PROG (ON/OFF)/
External button / switch: Range:| yes
Other data|
in open space up to 200 m
Operating temperature:
|
Operating position:| -15 až + 50 °C
Operating position:| any
Mounting:|
free at lead-in wires
Protection:| IP40
Overvoltage category:| III.
Contamination degree:| 2
Connection:|
screwless terminals
Connecting conductor:|
0.2-1.5 mm2 solid/fl exible
Dimensions:|
43 x 44 x 22 mm
Weight:| 31g 45 g
Related standards:|
EN 60730, EN 63044, EN 300 220, EN 301 489
- Control button input is at the supply voltage potential.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1
cm between each units.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device.
It is always a part of its packing. Installation and connection can be carried
out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while
observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling.
In case you notice any sign of damage, deformation, malfunction or missing
part, do not install this device and return it to its seller. It is necessary
to treat this product and its parts as electronic waste after its lifetime is
terminated. Before starting installation, make sure
that all wires, connected parts or terminals are de-energized. While mounting
and servicing observe safety regulations, norms, directives and professional,
and export regulations for working with electrical devices. Do not touch parts
of the device that are energized – life threat. Due to transmissivity of RF
signal, observe correct location of RF components in a building where the
installation is taking place. RF Control is designated only for mounting in
interiors. Devices are not designated for installation into exteriors and
humid spaces. The must not be installed into metal switchboards and into
plastic switchboards with metal door – transmissivity of RF signal is then
impossible. RF Control is not recommended for pulleys etc. – radiofrequency
signal can be shielded by an obstruction, interfered, battery of the
transceiver can get fl at etc. and thus disable remote control.
ELKO EP declares that the RFSAI-xxB-SL type of equipment complies with
Directives 2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full EU
Declaration of Conformity is at:
https://www.elkoep.com/switching-units-with-inputs-for-external-buttons
—-rfsai-11b-sl
https://www.elkoep.com/switching-units-with-inputs-for-external-buttons
—-rfsai-61b-sl
https://www.elkoep.com/switching-units-with-inputs-for-external-buttons
—rfsai-62b-sl
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
Tel.: +420 573 514 211, e-mail: elko@elkoep.com,
www.elkoep.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>