levenhuk Ermenrich NG60 Gas Detector User Manual

July 16, 2024
levenhuk

levenhuk Ermen rich NG60 Gas Detector User Manual

 Product Part

PRODUCT PART

Ermenrich NG60 Gas Detector

Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.

The kit includes: gas detector, USB cable, adapter for charging, aluminum carry case, user manual, and warranty.

Charging the device

This device uses a rechargeable Li-ion battery. Connect the power cable to the device and the DC adapter via a USB  plug and connect it to the AC power supply to charge the device. Fully charge for 6–8 hours. For fast charging, turn the device off. Working battery time is 16–18 hours.

Always turn off your device before charging it. Do not charge the device in potentially explosive atmospheres.

Getting started
Press the power button (5) and hold it for 3 seconds to turn the device on/off. The device will start the self-check: the LED indicators will blink twice, the device will emit a short vibration signal and then will beep twice. After the self-check, the device will display the preset information for low alarm value, high alarm value, and the detection range upper limit value for combustible gas, oxygen, hydrogen sulfide and carbon monoxide in sequence.
Settings
Press the power button (5) to enter the menu, to enter a submenu, to confirm the selection, and to save changes. Press the left (4) and right (6) buttons to scroll through the menu. You can view and set the time and date, and you can view the battery status. You can set a 4-digit password to prevent the device from accidental operation.

Zero adjustment
You can adjust the zero setting according to the actual detection value.
Enter the zero trim submenu, select the gas type, the value, and unit of measurement. Then, save the adjusted value. For example, if the displayed value is 3 instead of 0, you can set –0004 and save this value: after that the displayed detection value will be 0.
Alarm records
You can view or clear the previous alarm records in the Alarm Rec (Alarm records) section of the menu.
Alarm records view
To switch between records, press left (4) and right (6) buttons.
Alarm records deletion
To clear the alarm value, press the left button (4) and select OK. To cancel deletion, press the right button (6) and select Quit (Cancel).
Usage
Gas detection mode is set by default. The system returns to the gas detection mode after 5 seconds of idle time. The device will automatically analyze the gas environment and display the result on the screen.
Normal gas concentration
If the gas concentration is below the low alarm value, the detection result will be displayed on the screen.
Abnormal gas concentration
If the gas concentration is above the alarm value, the LED indicators and the backlight will light on, the device will vibrate and emit a beeping sound, and the current detection value will be displayed on the screen.

Gas type| Detection range| Optional range| Low alarm| High alarm| Resolution
---|---|---|---|---|---
Oxygen| 0–30% vol.| 0–30% vol.| 19.5| 23.5| 0.1% vol.
Methane| 0–4% CH4| 0–4% CH4| 1.00| 2.50| 0.01% CH4
Carbon monoxide| 0–1000ppm| 0–2000/5000ppm| 50| 200| 1ppm
Hydrogen sulfide| 0–100ppm| 0–50/200/1000ppm| 10| 20| 1/0.1ppm
Combustible gas| 0–100% LEL| 0–100% LEL| 20| 50| 1% LEL
Ammonia| 0–100ppm| 0–50/500/1000ppm| 20| 50| 1/0.1ppm
Hydrogen| 0–1000ppm| 0–40000ppm| 200| 500| 1/0.1ppm
Chlorine gas| 0–20ppm| 0–100/150ppm| 5| 10| 1/0.1ppm
Hydrogen chloride| 0–20ppm| 0–20/150ppm| 5| 10| 1/0.1ppm
Sulfur dioxide| 0–20ppm| 0–50/100ppm| 5| 10| 1/0.1ppm
Nitric oxide| 0–250ppm| 0–500/1000ppm| 20| 125| 1/0.1ppm
Nitrogen dioxide| 0–20ppm| 0–50ppm| 5| 10| 1/0.1ppm
Carbon dioxide| 0–5000ppm| 0–5%/10% vol. (infrared)| 1000/0.2| 2000/0.5| 1ppm/0.1% vol.
Hydrogen phosphide| 0–20ppm| 0–20ppm| 5| 10| 1ppm
Hydrogen cyanide| 0–20ppm| 0–20ppm| 10| 25| 1ppm
Epoxy acetylene| 0–100ppm| 0–100ppm| 20| 50| 1ppm
Epoxy ethane| 0–100ppm| 0–100ppm| 20| 50| 1ppm
---|---|---|---|---|---
Ozone| 0–100ppm| 0–20/100ppm| 20| 50| 0.1ppm
Methanal| 0–40ppm| 0–50/100ppm| 8| 20| 1/0.1ppm
Benzene| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Methyl benzene| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Dim| ethyl benzene| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Volatile organic compounds (VOC)| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Chloroethylene| 0–250ppm| 0–250ppm| 50| 125| 1ppm
Methyl alcohol| 0–30ppm| 0–30ppm| 6| 15| 1ppm
Isobutene| 0–90ppm| 0–90ppm| 18| 45| 1ppm
Alcohol| 0–80ppm| 0–80ppm| 16| 40| 1ppm

The display error for combustible gases is ±5%, for carbon monoxide is ±10%, for hydrogen sulfide is ±5%

History record

The device can save the records of gas concentration alarms. You can select, view, or clear the records.

Specifications

Combustible gases to be detected| EX*| H2S (hydrogen sulfide)| CO (carbon monoxide)| O2 (oxygen)
---|---|---|---|---
Detection range| 0–100% LEL**| 0–100ppm| 0–1000ppm| 0–30% vol.
Response time| < 45s
Low alarm| 20% LEL| 10ppm| 50ppm| 19.5% vol.
High alarm| 50% LEL| 20ppm| 200ppm| 23.5% vol.
Explosion protection| Ex Ib IIB T3 Gb
Dimensions| 130x45x65mm
Weight| 200g
Operating temperature range| –20…+50°C (operating), –10…+55°C (storage) /–4… +122°F (operating), –14…+131°F (storage)
Power supply| rechargeable Li-ion battery, 3.7V, 2000mA·h; 24V, 1A adapter for charging

  • EX – explosive gases (hydrogen, carbon monoxide, methane, ethane, propane, butane, ethylene, propylene, butene, acetylene, propyne,  butyne, hydrogen sulfide, phosphine, etc.)
    LEL – lower explosive limit
    The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance
The device is designed to measure the concentration of gas in the air. If you measure high density gas, you might damage the device. Do not use or store the device in the corrosive atmosphere. Store the device in a dry cool place. Do not expose the device to shock, continuous vibrations, or extreme high or low temperatures. Do not try to disassemble the device on your own for any reason. For calibration, repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Only use accessories and spare parts for this device that comply with the technical specifications. Always use only the recommended cleaning wipes and cleaning tools. Do not use any ethanol- or acetone-based fluids. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately

Battery safety instructions
The device is equipped with a built-in rechargeable lithium-ion battery. This avoids frequent battery replacement. Always switch the device off when not in use. If the battery charge is low, please recharge the device in time to ensure that the measurements are accurate. Do not overheat the battery. Do not discharge the battery completely. Only use the original charger.
Levenhuk International Warranty
Levenhuk products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met. For further details, please visit: levenhuk.com/warranty If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch
levenhuk Logo