Specifications
- Model: EPP-100 series
- DC Voltage
- EPP-100-12: 12V
- EPP-100-15: 15V
- EPP-100-24: 24V
- EPP-100-27: 27V
- EPP-100-48: 48V
- Rated Current
- Convection: 6.3A – 2.8A
- 20CFM Fan: 8.5A – 3.71A
- Rated Power
- Convection: 75.6W – 76.8W
- 20CFM Fan: 102W
- Ripple & Noise (max): 120mVp-p – 240mVp-p
- Voltage Adj. Range
- 11.76V – 12.6V
- 14.7V – 15.75V
- 23.52V – 25.2V
- 26.46V – 28.35V
- Line Regulation, Load Regulation, Setup Rise Time, Hold Up Time, Voltage Range, Frequency Range, Power Factor, Efficiency, AC Current, Inrush Current, Leakage Current details provided in the manual.
Product Usage Instructions
Safety Precautions
Before using the EPP-100 series power supply, read the user manual
carefully and adhere to all safety instructions provided.
Installation
- Ensure the input power matches the specified voltage range (90 ~ 264VAC, 127 ~ 370VDC).
- Connect the DC output of the power supply to your device following proper polarity.
Voltage Adjustment
Use the provided voltage adjustment range to set the appropriate output
voltage for your application.
Cooling
Ensure proper ventilation for the power supply, especially when operating
at higher current levels.
Maintenance
Regularly inspect the power supply for any damage or abnormal operation and
perform maintenance as needed.
FAQ
-
Q: What should I do if the power supply overheats during operation?
- A: Ensure proper ventilation around the power supply and check for any obstructions to airflow. If the issue persists, contact customer support.
-
Q: Can I use the EPP-100 series power supply outdoors?
- A: The EPP-100 series is designed for indoor use only. Avoid exposing it to moisture or extreme environmental conditions.
100W Single Output with PFC Function
EPP-100 series
Features
- 4″x2″ Compact size
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 92.5%
- Protections: Short circuit / Overload / Over voltage/Over temperature
- 75W free air convection, 100W with 20CM forced air
- LED indicator for power on
- No load power consumption<0.5W
- Built-in 12V/0.3A auxiliary output
- 3 years warranty
GTIN CODE MW
Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| EPP-100-12| EPP-100-15| EPP-100-24|
EPP-100-27| EPP-100-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 27V| 48V
RATED CURRENT (convection)| 6.3A| 5A| 3.2A| 2.8A| 1.6A
RATED CURRENT (20CFM FAN)| 8.5A| 6.67A| 4.2A| 3.71A| 2.1A
CURRENT RANGE (convection)| 0 ~ 6.3A| 0 ~ 5A| 0 ~ 3.2A| 0 ~
2.8A| 0 ~ 1.6A
CURRENT RANGE (20CFM FAN)| 0 ~ 8.5A| 0 ~ 6.67A| 0 ~ 4.2A| 0
~ 3.71A| 0 ~ 2.1A
RATED POWER (convection)| 75.6W| 75W| 76.8W| 75.6W| 76.8W
RATED POWER (20CFM FAN)| 102W| 100.05W| 100.8W| 100.17W|
100.8W
RIPPLE & NOISE (max.) **Note.2| 120mVp-p| 150mVp-p| 240mVp-p|
240mVp-p| 300mVp-p
VOLTAGE ADJ. RANGE| 11.76 ~ 12.6V| 14.7 ~ 15.75V| 23.52 ~ 25.2V| 26.46 ~
28.35V| 47.04 ~ 50.4V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.5| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC PF>0.98/115VAC at full
load
EFFICIENCY (Typ.)| 91%| 91%| 92%| 92.5%| 92.5%
AC CURRENT (Typ.)| 1.4A/115VAC 0.7A/230VAC
INRUSH CURRENT (Typ.)| COLD START 70A/230VAC
LEAKAGE CURRENT| <2mA/240VAC
PROTECTION| OVER LOAD| 105 ~ 145% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 13.2 ~ 15.6V| 16.83 ~ 19.5V| 27.7 ~ 31.5V| 30.2 ~ 34.05V|
51.3 ~ 62.7V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| 110℃±10℃ (RTH2),110℃±5℃ (TSW2)
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION| AUXILIARY POWER(AUX)| **
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 45℃)
OPERATING ALTITUDE Note.6| 2000 meters
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004
approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC
/ 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2401.7K hrs min. Telcordia SR-332 (Bellcore) ;
249.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 101.650.829mm (LWH)
PACKING| 0.2Kg; 72pcs/15.4Kg/0.82CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The ambient temperature derating of 3.5℃/1000m with Fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Block Diagram
Output Derating
Output Derating VS Input Voltage
Downloaded from Arrow.com
References
Read User Manual Online (PDF format)