MEAN WELL MFM-20 Series High Reliable Green Medical On Board Type
Product Information
Product Specifications:
- Model: MFM-20 series
- Power Output: 20W
- Type: On Board
- Color: Green
- Compliance: EN 60601-1, IEC 60601-1, BS EN/EN60335-1, ANSI/AAMI ES60601-1, BS EN/EN60601-1, IEC60601-1, TPTC004
- Size: 1.93×0.94 inches
- Medical Safety Approval: 2 x MOPP (Means of Patient Protection)
- Application: Suitable for BF application with appropriate system consideration
- No load power consumption
Product Usage Instructions
-
Safety Precautions:
Before using the product, carefully read and understand the safety instructions provided in the user manual. -
Installation:
Ensure the power supply is disconnected before installation. Follow the manufacturer’s guidelines for proper installation. -
Power Output:
Connect the product to the appropriate devices ensuring compatibility with the power output of 20W. -
Maintenance:
Regularly inspect the product for any signs of damage or wear. Do not attempt to repair the product yourself; contact authorized service personnel if needed. -
Storage:
Store the product in a cool, dry place away from direct sunlight and moisture to ensure its longevity.
Frequently Asked Questions:
-
Q: Is this product suitable for medical applications?
A: Yes, this product is approved for medical safety (2 x MOPP). -
Q: What are the dimensions of this product?
A: The product measures 1.93×0.94 inches in size.
Features
-
1.93″x0.94″ compact size
-
Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
-
Suitable for BF application with appropriate system consideration
-
No load power consumption<0.1W
-
Extremely low leakage current
-
Wide operating temp. range -35 ~ +85°C
-
EMI Class B for class II configuration
-
Protections:
Short circuit/Overload/Over voltage/Over temperature -
No minimum load required
-
3 years warranty
Applications
- Portable medical device
- Mobile clinical workstation
- Medical computer monitor
- Medical examination instrument
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
MFM-20 is a 20W high-density and small size (4923.823mm) AC/DC on-board type medical power supply series. It features the operation for 80~264VAC, a low no-load power consumption of less than 0.1W, high efficiency of up to 87%, Class II (no FG) double insulation, outstanding dissipation, 5G anti- vibration, high EMC performance, 4KVAC isolation, etc. The design observes IEC/BS EN/EN60601-1 and ANSI/AAMI ES60601-1 version three with 2xMOPP level and ultra-low leakage current(<80 µA). It is very suitable for BF (patient contact) type medical devices or relevant equipment.
Model Encoding
SPECIFICATION
MODEL| MFM-20-3.3| MFM-20-5| MFM-20-12| MFM-20-15|
MFM-20-24
---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V
RATED CURRENT| 4.5A| 4A| 1.8A| 1.4A| 0.9A
CURRENT RANGE Note.2| 0 ~ 4.5A| 0 ~ 4A| 0 ~ 1.8A| 0 ~ 1.4A| 0 ~ 0.9A
PEAK CURRENT| 4.95A| 4.4A| 1.98A| 1.54A| 0.99A
RATED POWER| 14.9W| 20W| 21.6W| 21W| 21.6W
PEAK LOAD(10sec.) **Note.3| 16.3W| 22W| 23.8W| 23.1W| 23.8W
RIPPLE & NOISE (max.) **Note.4| 150mVp-p| 150mVp-p| 150mVp-p|
180mVp-p| 180mVp-p
VOLTAGE TOLERANCE Note.5| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.3%| ±0.3%| ±0.3%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1500ms, 30ms/230VAC 1500ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 40ms/230VAC 10ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.6| 80 ~ 264VAC
FREQUENCY RANGE| 47 ~ 440Hz
EFFICIENCY (Typ.)| 81%| 85%| 85.5%| 87%| 87%
AC CURRENT (Typ.)| 0.75A/115VAC 0.5A/230VAC
INRUSH CURRENT (Typ.)| COLD START 20A/115VAC 45A/230VAC
LEAKAGE CURRENT (max.) Note.7| Touch current <80μA/264VAC
PROTECTION| OVERLOAD| 110% ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE
| 3.8 ~ 5V| 5.8 ~ 6.8V| 13.8 ~ 16.2V| 17.3 ~ 20.3V| 27.6 ~ 32.4V
Protection type: Shut off o/p voltage, clamping by Zener diode
OVER TEMPERATURE| Protection type: Shut down o/p voltage, recovers
automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -35 ~ +85℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering:
390℃,3s (max.)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,
Y, Z axes
OPERATING ALTITUDE Note.8| 5000 meters
SAFETY & EMC
(Note.9)
| SAFETY STANDARDS| IEC 60601-1:2005+A1,TUV BS EN/ EN 60601-1:2006+A1+A12+A2,ANSI/AAMI ES60601-1:2005/A2:2021, CAN/CSA C22.2 No. 60601-1:2014+A2,IEC 60335-1:2010/AMD2:2016,
Dekra BS EN/ EN 60335-1:2012+A11+A13+A1+A14+A2+A15 ,EAC TP TC 004 approved
ISOLATION LEVEL| Primary-Secondary: 2xMOPP
WITHSTAND VOLTAGE| I/P-O/P:4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55011 (CISPR11)| Class B
Radiated emission| BS EN/EN55011 (CISPR11)| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55035, BS EN/EN60601-1-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, 10V
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage dip, interruption
| ****
BS EN/EN61000-4-11
| 100% dip 1 periods, 30% dip 25 periods,
100% interruptions 250 periods
OTHERS| MTBF| 7319.8K hrs min. Telcordia SR-332 (Bellcore) ;
1210.1K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 4923.823mm (LWH) or 1.93 ″0.94″0.91″ inch
PACKING| 0.028Kg; 200pcs/6.6Kg/0.94CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load, and 25℃ of ambient temperature.
2. No minimum load required.
3. 33% Duty cycle maximum within every 30 seconds. The average output power should not exceed the rated power.
4. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
5. Tolerance: includes set up tolerance, line regulation, and load regulation.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
7. Touch current was measured from primary input to DC output.
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
9. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Mechanical Specification
Installation Manual
Please refer to: http://www.meanwell.com/manual.html.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>