MEAN WELL RD-65 Series 65W Dual Output Switching Power Supply Owner’s Manual
- July 3, 2024
- MEAN WELL
Table of Contents
MEAN WELL RD-65 Series 65W Dual Output Switching Power Supply
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Features
- Universal AC input/ Full range
- Protections: Short circuit/ Overload/ Over volta
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 1 05°C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70°C
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- 3 years warranty
SPECIFICATION
MODEL | RD-65A | RD-65B |
---|---|---|
OUTPUT | OUTPUT NUMBER | CH1 |
DC VOLTAGE | 5V | 12V |
RATED CURRENT | 6A | 3A |
CURRENT RANGE Note.6 | 0 ~ 8A | 0 ~ 4A |
RATED POWER Note.6 | 66W | 68W |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% |
LINE REGULATION Note.4 | ±0.5% | ±1.5% |
LOAD REGULATION Note.5 | ±0.5% | ±3.0% |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 60ms/230VAC 14ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for |
5sec. Without damage)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 78%| 77%
AC CURRENT (Typ.)| 2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
ENVIRONMENT| WORKING TEMP.| -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z
axes
SAFETY & EMC (Note 7)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC
TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS
EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2940.2K hrs min. Telcordia SR-332 (Bellcore) ; 541.0K hrs min.
MIL-HDBK-217F (25℃)
DIMENSION| 1299838mm (LWH)
PACKING| 0.44Kg; 30pcs/14.2Kg/0.72CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.
- Line regulation is measured from low line to high line at rated load.
- Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
- Each output can work within current range. But total output power can’t exceed rated output power.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Terminal Pin No. Assignment
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4,6 | DC OUTPUT COM |
2 | AC/N | 5 | DC OUTPUT +V2 |
3 | FG | 7 | DC OUTPUT +V1 |
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Documents / Resources
| MEAN
WELL RD-65 Series 65W Dual Output Switching Power
Supply
[pdf] Owner's Manual
RD-65A, RD-65B, RD-65 Series 65W Dual Output Switching Power Supply, RD-65
Series, RD-65 Series Power Supply, 65W Dual Output Switching Power Supply, 65W
Power Supply, Dual Output Switching Power Supply, Switching Power Supply, Dual
Output Power Supply, Power Supply
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>