Features

  • Universal AC input/ Full range
  • Protections: Short circuit/ Overload/ Over volta
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 1 05°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

SPECIFICATION

MODEL RD-65A RD-65B
OUTPUT OUTPUT NUMBER CH1
DC VOLTAGE 5V 12V
RATED CURRENT 6A 3A
CURRENT RANGE Note.6 0 ~ 8A 0 ~ 4A
RATED POWER Note.6 66W 68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±6.0%
LINE REGULATION Note.4 ±0.5% ±1.5%
LOAD REGULATION Note.5 ±0.5% ±3.0%
SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC 14ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for

5sec. Without damage)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 78%| 77%
AC CURRENT (Typ.)| 2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 7)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2940.2K hrs min. Telcordia SR-332 (Bellcore) ; 541.0K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1299838mm (LWH)
PACKING| 0.44Kg; 30pcs/14.2Kg/0.72CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on   a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4,6 DC OUTPUT COM
2 AC/N 5 DC OUTPUT +V2
3 FG 7 DC OUTPUT +V1

Block Diagram

Derating Curve

Output Derating VS Input Voltage

User’s Manual

Documents / Resources

| MEAN WELL RD-65 Series 65W Dual Output Switching Power Supply [pdf] Owner's Manual
RD-65A, RD-65B, RD-65 Series 65W Dual Output Switching Power Supply, RD-65 Series, RD-65 Series Power Supply, 65W Dual Output Switching Power Supply, 65W Power Supply, Dual Output Switching Power Supply, Switching Power Supply, Dual Output Power Supply, Power Supply
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals