MEAN WELL ELG-240 Series 180 to 240W Constant Voltage plus Constant Current LED Driver Owner’s Manual

July 3, 2024
MEAN WELL

ELG-240 Series 180 to 240W Constant Voltage plus Constant Current LED

Driver

“`html

Specifications:

  • * Model: ELG-240-24, ELG-240-36, ELG-240-42, ELG-240-48,  

    ELG-240-54

    • DC Voltage:
    • ELG-240-24: 24V
    • ELG-240-36: 36V
    • ELG-240-42: 42V
    • ELG-240-48: 48V
    • ELG-240-54: 54V
    • Rated Power:
    • ELG-240-24: 180W
    • ELG-240-36: 180W
    • ELG-240-42: 179.76W
    • ELG-240-48: 240W
    • ELG-240-54: 240.3W
    • Ripple & Noise (max.):
    • ELG-240-24: 200mVp-p
    • ELG-240-36: 250mVp-p
    • ELG-240-42: 250mVp-p
    • ELG-240-48: 250mVp-p
    • ELG-240-54: 350mVp-p

Product Usage Instructions:

1. Installation:

Follow these steps to install the LED Driver:

  1. Ensure the power source is turned off.
  2. Connect the input wires to the appropriate power source.
  3. Connect the output wires to the LED load.
  4. Secure all connections properly.

2. Voltage and Current Adjustment:

To adjust the voltage and current settings:

  1. Use a screwdriver to adjust the built-in potentiometer for
    voltage adjustment within the specified range.

  2. Similarly, adjust the potentiometer for current adjustment
    within the specified range.

FAQ:

Q: How many units of ELG-240 LED Drivers can be connected on a

16A circuit breaker?

A: You can connect up to 4 units with a circuit breaker of type
B or up to 6 units with a circuit breaker of type C at 230VAC.

“`

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

User’s Manual

IP65 IP67

IS 15885(Part 2/Sec13)

THOMAS SAMUEL

THOMAS SAMUEL

R-41027766

8

{

A

Dx

Downloaded from Arrow.com.

File Name:ELG-240-SPEC 2024-01-08

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

SPECIFICATION

MODEL

ELG-240-24

ELG-240-36

ELG-240-42

DC VOLTAGE

24V

CONSTANT CURRENT REGION Note.2 12 ~ 24V

RATED CURRENT

10A

36V 18 ~ 36V 6.66A

42V 21 ~ 42V 5.71A

RATED POWER

200VAC ~ 305VAC 240W 100VAC ~ 180VAC

239.76W

239.82W

OUTPUT

180W

180W

179.76W

RIPPLE & NOISE (max.) Note.3 200mVp-p

250mVp-p

250mVp-p

VOLTAGE ADJ. RANGE

Adjustable for A/AB-Type only (via built-in potentiometer)

22.4 ~ 25.6V

33.5 ~ 38.5V

39 ~ 45V

CURRENT ADJ. RANGE

Adjustable for A/AB-Type only (via built-in potentiometer)

5 ~ 10A

3.33 ~ 6.66A

2.86 ~ 5.71A

VOLTAGE TOLERANCE Note.4 ±2.0%

±2.0%

±2.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME Note.6 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC

HOLD UP TIME (Typ.)

10ms/ 230VAC 10ms/ 115VAC

VOLTAGE RANGE

100 ~ 305VAC 142 ~ 431VDC Note.5 (Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE POWER FACTOR

47 ~ 63Hz
PF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC@full load (Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

ELG-240-48 48V 24 ~ 48V 5.0A
240W
180W 250mVp-p
44.8 ~ 51.2V
2.5 ~ 5A ±2.0% ±0.5% ±0.5%

ELG-240-54 54V 27 ~ 54V 4.45A
240.3W
180.36W 350mVp-p
50 ~ 57V
2.23 ~ 4.45A ±2.0% ±0.5% ±0.5%

TOTAL HARMONIC DISTORTION

THD< 20%(@load50%/115VC,230VAC; @load75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)

INPUT

EFFICIENCY (Typ.)

92%

92%

92.5%

93%

93%

AC CURRENT INRUSH CURRENT(Typ.)

2.2A / 115VAC 1.5A / 230VAC 1.2A/277VAC COLD START 60A(twidth=510s measured at 50% Ipeak) at 230VAC; Per NEMA 410

MAX. No. of PSUs on 16A CIRCUIT BREAKER

4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

NO LOAD / STANDBY

No load power consumption <0.5W for Blank / A / Dx / D-Type

POWER CONSUMPTION Note.7 Standby power consumption <0.5W for B / AB / DA-Type

OVER CURRENT
SHORT CIRCUIT PROTECTION
OVER VOLTAGE
OVER TEMPERATURE WORKING TEMP. MAX. CASE TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS

SAFETY & DALI STANDARDS

EMC

WITHSTAND VOLTAGE

ISOLATION RESISTANCE

EMC EMISSION

95 ~ 108%

Constant current limiting, recovers automatically after fault condition is removed

Hiccup mode, recovers automatically after fault condition is removed

27 ~ 34V

42 ~ 49V

47 ~ 54V

54 ~ 63V

60 ~ 67V

Shut down output voltage, re-power on to recover

Shut down output voltage, re-power on to recover Tcase=-40 ~ +90 (Please refer to ” OUTPUT LOAD vs TEMPERATURE” section)

Tcase=+90

20 ~ 95% RH non-condensing

-40 ~ +90, 10 ~ 95% RH

±0.03%/ (0 ~ 60)

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

UL8750(type”HL”), CSA C22.2 No. 250.13-12;IEC/BS EN/EN/AS/NZS 61347-1, IEC/BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384; EAC TP TC 004;BISIS15885(for 24/24A/24B/24DA/36/36A/36B/42/42A/42B/48/48A/48B/54/54A/54ADA/54B only); GB19510.14,GB19510.1; IP65 or IP67;KC61347-1,KC61347-2-13 approved

Compliance to IEC62386-101,102,(207 by request) for DA Type only

I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load50%) ; BS EN/EN61000-3-3; GB/T 17743, GB17625.1;EAC TP TC 020; KC KN15,KN61547

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV);EAC TP TC 02; KC KN15,KN61547

MTBF

2391.4K hrs min. Telcordia SR-332 (Bellcore) ; 190.7K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

2447137.5mm (LWH)

PACKING

1.22Kg; 12pcs / 15.2Kg / 0.72CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. Please refer to “DRIVING METHODS OF LED MODULE”.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7. No load/standby power consumption is specified for 230VAC input.

8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the

complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70 or less.

10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com

11. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

12. For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf

13. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently

connected to the mains.
Downloaded from Arrow.coPmro.duct Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:ELG-240-SPEC 2024-01-08

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

Block Diagram

PFC fosc : 50~120KHz PWM fosc : 60~130KHz

EMI FILTER

I/P

&

RECTIFIERS

PFC CIRCUIT

POWER

RECTIFIERS

Vo+

SWITCHING

& FILTER

Vo-

O.L.P.

O.T.P. PFC CONTROL

O.L.P.

PWM & PFC CONTROL

DETECTION CIRCUIT
O.V.P.

CASE :Protective Earth

DRIVING METHODS OF LED MODULE

This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.

100

Vo(%)

50 (min.)

(A) Constant
Voltage area

(B) Constant Current area

(C) Hiccup Protection

50

100

Io(%)

Typical output current normalized by rated current (%)

In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL.

Downloaded from Arrow.com.

File Name:ELG-240-SPEC 2024-01-08

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

DIMMING OPERATION

ACN(Blue) ACL(Brown)

ELG-240

Vo-(Black) Vo+(Red) DIM+(Purple)* DIM-(Pink)**

3 in 1 dimming function (for B/AB-Type)
Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal or resistance. Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. Dimming source current from power supply: 100A (typ.)

  • DIM+ for B/AB-Type DA+ for DA-Type PROG+ for D2-Type
  • *DIM- for B/AB-Type DA- for DA-Type PROG- for D2-Type

Applying additive 0 ~ 10VDC

100%

90%

Vo+ +

80%

70%

Output current (%)

Vo-

60%

50%

DIM+ +

40%

Additive Voltage

30%

20%

DIM-

10%

“DO NOT connect “DIM- to Vo-”

0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V

Dimming input: Additive voltage

Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):

Vo+ +

Vo-

DIM+

Additive PWM signal DIM-

“DO NOT connect “DIM- to Vo-”

Output current (%)

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty cycle of additive 10V PWM signal dimming input

Applying additive resistance:

100%

Output current (%)

Vo+ +
VoDIM+

90%

80%

70%

60%

50%

40%
Additive Resistance
30%

DIM-

20%

“DO NOT connect “DIM- to Vo-”

10%

0% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N

(N=driver quantity for synchronized dimming operation)

Dimming input: Additive resistance

Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%. 2. The output current could drop down to 0% when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle.

File Name:ELG-240-SPEC 2024-01-08

Downloaded from Arrow.com.

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

DALI Interface (primary side; for DA-Type) Apply DALI signal between DA+ and DA-. DALI protocol comprises 16 groups and 64 addresses. First step is fixed at 8% of output.
Smart timer dimming function (for Dxx-Type by User definition) MEAN WELL Smart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details.
Ex : D01-Type: the profile recommended for residential lighting

Set up for D01-Type in Smart timer dimming software program:

T1

T2

T3

T4

TIME**

06:00

07:00

11:00

LEVEL** 100%

70%

50%

70%

Dimming Level(%)

Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a residential lighting application adopts D01-Type, when turning on the power supply at 6:00pm, for instance:
[1] The power supply will switch to the constant current level at 100% starting from 6:00pm. [2] The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00am, which is 14:00 after the power supply turns on.
Ex: D02-Type: the profile recommended for street lighting

Set up for D02-Type in Smart timer dimming software program:

TIME LEVEL

T1 01:00 50%

T2 03:00 80%

T3 8:00 100%

T4

T5

11:00

60%

80%

Dimming Level(%)

Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance: [1] The power supply will switch to the constant current level at 50% starting from 5:00pm. [2] The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on. [5] The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The
constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
File Name:ELG-240-SPEC 2024-01-08
Downloaded from Arrow.com.

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

Ex: D03-Type: the profile recommended for tunnel lighting

Set up for D03-Type in Smart timer dimming software program:

T1

T2

T3

TIME**

01:30

11:00

LEVEL** 70%

100%

70%

Dimming Level(%)

Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance: [1] The power supply will switch to the constant current level at 70% starting from 4:30pm. [2] The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on. [3] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.

Downloaded from Arrow.com.

File Name:ELG-240-SPEC 2024-01-08

LOAD (%)

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

OUTPUT LOAD vs TEMPERATURE(Note.10)

100
80 230VAC input only
60
40
20

110VAC

LOAD (%)

100

80 230VAC input only
60
40

110VAC

20

-40

-25 0 10

20

30

50

60

70 (HORIZONTAL)

AMBIENT TEMPERATURE,Ta ()
If ELG-240 operates in Constant Current mode with the rated current, the maximum workable Ta is 60.

-40 -25 0

20

45

55

65

75

90 (HORIZONTAL)

Tcase ()

STATIC CHARACTERISTIC
100 90 80 75 70 60 50 40
100 120 140 160 180 200 240 250 260 270 280 305
INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage.

PF

POWER FACTOR (PF) CHARACTERISTIC
Tcase at 80 Constant Current Mode

1

0.98

0.96

0.94 277V(240W)

0.92

230V(240W)

0.9

115V(180W)

0.88

0.86

50%

60%

70%

80%

90%

100%

LOAD

TOTAL HARMONIC DISTORTION (THD)

48V Model, Tcase at 80

18%

16%

14%

12%

10%

8%

6%

4%

50%

60%

70%

80%

LOAD

277V(240 W) 230V(240 W) 115V(180 W)

90%

100%

EFFICIENCY(%)

EFFICIENCY vs LOAD
ELG-240 series possess superior working efficiency that up to 93% can be reached in field applications. 48V Model, Tcase at 80

96 94 92 90 88 86 84 82 80
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

277V(240W) 230V(240W) 115V(180W)

LOAD

File Name:ELG-240-SPEC 2024-01-08

THD LOAD (%)

Downloaded from Arrow.com.

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

LIFE TIME

LIFETIME(Kh)

120

100

80

60

40

20

0

20

30

40

50

60

70

80

90

Tcase ( )

Downloaded from Arrow.com.

File Name:ELG-240-SPEC 2024-01-08

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

MECHANICAL SPECIFICATION
Blank-Type

244

233

300±20

220

CASE NO.: 262A Unit:mm
300±20

ACN(Blue) ACL(Brown)

SJOW 17AWGx2C &H05RN-F 1.0mm2

tc

90

4-4.5
tc : Max. Case Temperature

Vo-(Black) Vo+(Red) SJOW 17AWGx2C &05RN-F 1.0mm2

71 53.8 32 37 37.5

A-Type

300±20

ACN(Blue) ACL(Brown)

SJOW 17AWGx2C &H05RN-F 1.0mm2

71 53.8

244 233 220

tc

90

4-4.5
tc : Max. Case Temperature

300±20
Vo-(Black) Vo+(Red) SJOW 17AWGx2C &05RN-F 1.0mm2

32 37 37.5

21.01

Downloaded from Arrow.com.

14.5 38.5

File Name:ELG-240-SPEC 2024-01-08

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

AB-Type

300±20

ACN(Blue) ACL(Brown)

SJOW 17AWGx2C &H05RN-F 1.0mm2

71 53.8

244 233 220

tc

90

4-4.5
tc : Max. Case Temperature

300±20 SJOW 17AWGx2C &05RN-F 1.0mm2 UL2517 20AWGx2C

Vo-(Black) Vo+(Red) DIM+(Purple) DIM-(Pink)

32 37 37.5

21.01

14.5 38.5

B/DA/D2-Type

300±20

ACN(Blue) ACL(Brown)

SJOW 17AWGx2C &H05RN-F 1.0mm2

244 233 220

tc

90

4-4.5
tc : Max. Case Temperature

300±20 SJOW 17AWGx2C &05RN-F 1.0mm2 UL2517 20AWGx2C

Vo-(Black) Vo+(Red) DIM+(Purple)* DIM-(Pink)**

  • DIM+ for B-Type DA+ for DA-Type PROG+ for D2-Type
  • *DIM- for B-Type DA- for DA-Type PROG- for D2-Type

71 53.8 32 37 37.5

Downloaded from Arrow.com.

File Name:ELG-240-SPEC 2024-01-08

E L G – 2 4 0 180~240W Constant Voltage + Constant Current LED Driver

series

3Y Model (3-wire input)

300±20

AC/N(Blue) AC/L(Brown) PE (Green/Yellow)

SJOW 17AWGx3C &H05RN-F 1.0mm2

71 53.8 32

244 233 220

tc

90

4-4.5
tc : Max. Case Temperature

SJOW 17AWGx2C &05RN-F 1.0mm2

Note1: Please connect the case to PE for the complete EMC deliverance and safety use. Note2: Please contact MEAN WELL for input wiring option with PE.
Recommend Mounting Direction

INSTALLATION MANUAL
Please refer to:http://www.meanwell.com/manual.html

Downloaded from Arrow.com.

File Name:ELG-240-SPEC 2024-01-08

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals