MEAN WELL HRP-600 Series 600W Single Output with PFC Function Owner’s Manual

July 2, 2024
MEAN WELL

HRP-600 Series 600W Single Output with PFC Function

“`html

Specifications

  • Model: HRP-600 series

  • Output:

    • DC Voltage:

    • 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V

    • Rated Current: 120A

    • Current Range: 0 ~ 120A

    • Rated Power:

    • For 3.3V and 5V: 396W

    • For other voltages: 600W

    • Ripple & Noise (max.): 120mVp-p for 3.3V and 150mVp-p for
      other voltages

    • Voltage Adjustment Range:

    • For 3.3V: 2.8 ~ 3.8V

    • For 5V: 4.3 ~ 5.8V

    • And similar ranges for other voltages

    • Line Regulation, Load Regulation, Setup, Rise Time, Hold Up
      Time, Voltage Range, Frequency Range, Power Factor, Efficiency, AC
      Current, Inrush Current are specified for different output
      voltages.

  • Input:

    • Voltage Range: 85 ~ 264VAC, 120 ~ 370VDC

    • Frequency Range: 47 ~ 63Hz

    • Power Factor: PF>0.93/230VAC, PF>0.99/115VAC at full
      load

    • Efficiency: Ranges from 78.5% to 89%

    • AC Current, Inrush Current, Leakage Current specified for
      different conditions.

Product Usage Instructions

1. Installation:

Ensure the input voltage matches the specified range. Connect
the output leads to the appropriate devices securely.

2. Powering On:

After installation, switch on the power supply and verify that
the output voltages are within the specified ranges.

3. Voltage Adjustment:

If necessary, use the voltage adjustment range to fine-tune the
output voltage to match the requirements of your devices.

4. Monitoring:

Regularly monitor the output voltages and currents to ensure
stable operation of your connected devices.

5. Maintenance:

Follow recommended maintenance schedules provided in the user
manual to keep the power supply in optimal condition.

Frequently Asked Questions (FAQ)

Q: What is the maximum ripple and noise for different output

voltages?

A: The maximum ripple and noise are specified as 120mVp-p for
3.3V and 150mVp-p for other voltages.

Q: How do I adjust the output voltage?

A: Use the voltage adjustment range specified for each output
voltage to adjust the output voltage as needed.

Q: What is the typical efficiency of the power supply?

A: The efficiency ranges from 78.5% to 89% depending on the
output voltage.

Q: What should I do if the input voltage exceeds the specified

range?

A: Avoid connecting the power supply to voltages outside the
specified range to prevent damage to the unit.

“`

600W Single Output with PFC Function

HRP-600 series

User’s Manual

SPECIFICATION

UL62368-1

Bauar t gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1

TPTC004

IEC62368-1

MODEL

HRP-600-3.3 HRP-600-5 HRP-600-7.5 HRP-600-12 HRP-600-15 HRP-600-24 HRP-600-36 HRP-600-48

OUTPUT

DC VOLTAGE

3.3V

5V

RATED CURRENT

120A

120A

CURRENT RANGE

0 ~ 120A

0 ~ 120A

RATED POWER

396W

600W

RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p

VOLTAGE ADJ. RANGE

2.8 ~ 3.8V 4.3 ~ 5.8V

VOLTAGE TOLERANCE Note.3 ±2.0%

±2.0%

LINE REGULATION

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±1.0%

SETUP, RISE TIME

1800ms, 50ms/230VAC

7.5V

12V

15V

80A

53A

43A

0 ~ 80A

0 ~ 53A

0 ~ 43A

600W

636W

645W

150mVp-p 150mVp-p 150mVp-p

6.8 ~ 9V ±2.0%

10.2 ~ 13.8V 13.5 ~ 18V

±1.0%

±1.0%

±0.5%

±0.3%

±0.3%

±1.0%

±0.5%

±0.5%

3600ms, 50ms/115VAC at full load

24V 27A 0 ~ 27A 648W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5%

36V 17.5A 0 ~ 17.5A 630W 200mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5%

48V 13A 0 ~ 13A 624W 240mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5%

HOLD UP TIME (Typ.)

16ms/230VAC 16ms/115VAC at full load

VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.93/230VAC PF>0.99/115VAC at full load

INPUT

EFFICIENCY (Typ.)

78.5%

82%

86%

88%

88%

88%

89%

89%

AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

7.6A/115VAC 3.6A/230VAC 35A/115VAC 70A/230VAC

LEAKAGE CURRENT

<1.2mA / 240VAC

OVERLOAD

105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

3.96 ~ 4.62V 6 ~ 7V

9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V

Protection type : Shut down o/p voltage, re-power on to recover

41.4 ~ 48.6V

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION DC OK SIGNAL FAN CONTROL (Typ.) WORKING TEMP.

PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V Load 35±15% or RTH250 Fan on -40 ~ +70 (Refer to “Derating Curve”)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved

SAFETY & WITHSTAND VOLTAGE

EMC

ISOLATION RESISTANCE

(Note 4)

EMC EMISSION

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020

57.6 ~ 67.2V

EMC IMMUNITY MTBF

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level, EAC TP TC 020 1333.6K hrs min. Telcordia SR-332 (Bellcore) ; 140.7K hrs min. MIL-HDBK-217F (25)

OTHERS NOTE

DIMENSION

21810563.5mm (LWH)

PACKING

1.5Kg;8pcs/13Kg/1.34CUFT

http://www.meanwell.com) https://www.meanwell.com/serviceDisclaimer.aspx

File Name:HRP-600-SPEC 2022-08-08

600W Single Output with PFC Function

Mechanical Specification
152.4

20.75

10 8.2

Air flow direction
I/P 1 2 3
12max.

63.5

4-M4 L=6
218 152.4 8-M4 L=4 (Both Sides)

HRP-600 series

32.8
O/P 1 2 3 4 5 6

9.2

11

Case No. 977A Unit:mm
12 34

105

CN100 LED
SVR1 (Vo ADJ.)

32.8 18max.

12.5 38.3 63.5

AC Input Terminal Pin No. Assignment

Pin No. Assignment

1

AC/L

2

AC/N

3

FG

Block Diagram

I/P

EMI FILTER

FG

Derating Curve

DC Output Terminal Pin No. Assignment

Pin No. Assignment

1~3

-V

4~6

+V

Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent

Pin No. Assignment Mating Housing Terminal

1

DC-OK

2

GND

HRS DF11-4DS HRS DF11-**SC

3

+S

or equivalent or equivalent

4

-S

ACTIVE INRUSH CURRENT LIMITING

RECTIFIERS &
PFC
O.T.P.
PFC CONTROL

POWER SWITCHING
O.L.P.
PWM CONTROL

RECTIFIERS &
FILTER
DETECTION CIRCUIT O.T.P. O.V.P.

PWM fosc : 70KHz +S +V -V -S
DC OK

Output Derating VS Input Voltage

LOAD (%) LOAD(%)

125

100

100

90

80 80
70

50

60

50

20

40

-40

0

10

20

30

40

50

60 70 (HORIZONTAL)

85

100

125

135

155

264

AMBIENT TEMPERATURE ()

INPUT VOLTAGE (V) 60Hz

File Name:HRP-600-SPEC 2022-08-08