HRP-600 Series 600W Single Output with PFC Function
“`html
Specifications
-
Model: HRP-600 series
-
Output:
-
DC Voltage:
-
3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V
-
Rated Current: 120A
-
Current Range: 0 ~ 120A
-
Rated Power:
-
For 3.3V and 5V: 396W
-
For other voltages: 600W
-
Ripple & Noise (max.): 120mVp-p for 3.3V and 150mVp-p for
other voltages -
Voltage Adjustment Range:
-
For 3.3V: 2.8 ~ 3.8V
-
For 5V: 4.3 ~ 5.8V
-
And similar ranges for other voltages
-
Line Regulation, Load Regulation, Setup, Rise Time, Hold Up
Time, Voltage Range, Frequency Range, Power Factor, Efficiency, AC
Current, Inrush Current are specified for different output
voltages.
-
-
Input:
-
Voltage Range: 85 ~ 264VAC, 120 ~ 370VDC
-
Frequency Range: 47 ~ 63Hz
-
Power Factor: PF>0.93/230VAC, PF>0.99/115VAC at full
load -
Efficiency: Ranges from 78.5% to 89%
-
AC Current, Inrush Current, Leakage Current specified for
different conditions.
-
Product Usage Instructions
1. Installation:
Ensure the input voltage matches the specified range. Connect
the output leads to the appropriate devices securely.
2. Powering On:
After installation, switch on the power supply and verify that
the output voltages are within the specified ranges.
3. Voltage Adjustment:
If necessary, use the voltage adjustment range to fine-tune the
output voltage to match the requirements of your devices.
4. Monitoring:
Regularly monitor the output voltages and currents to ensure
stable operation of your connected devices.
5. Maintenance:
Follow recommended maintenance schedules provided in the user
manual to keep the power supply in optimal condition.
Frequently Asked Questions (FAQ)
Q: What is the maximum ripple and noise for different output
voltages?
A: The maximum ripple and noise are specified as 120mVp-p for
3.3V and 150mVp-p for other voltages.
Q: How do I adjust the output voltage?
A: Use the voltage adjustment range specified for each output
voltage to adjust the output voltage as needed.
Q: What is the typical efficiency of the power supply?
A: The efficiency ranges from 78.5% to 89% depending on the
output voltage.
Q: What should I do if the input voltage exceeds the specified
range?
A: Avoid connecting the power supply to voltages outside the
specified range to prevent damage to the unit.
“`
600W Single Output with PFC Function
HRP-600 series
User’s Manual
SPECIFICATION
UL62368-1
Bauar t gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1
TPTC004
IEC62368-1
MODEL
HRP-600-3.3 HRP-600-5 HRP-600-7.5 HRP-600-12 HRP-600-15 HRP-600-24 HRP-600-36 HRP-600-48
OUTPUT
DC VOLTAGE
3.3V
5V
RATED CURRENT
120A
120A
CURRENT RANGE
0 ~ 120A
0 ~ 120A
RATED POWER
396W
600W
RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V 4.3 ~ 5.8V
VOLTAGE TOLERANCE Note.3 ±2.0%
±2.0%
LINE REGULATION
±0.5%
±0.5%
LOAD REGULATION
±1.0%
±1.0%
SETUP, RISE TIME
1800ms, 50ms/230VAC
7.5V
12V
15V
80A
53A
43A
0 ~ 80A
0 ~ 53A
0 ~ 43A
600W
636W
645W
150mVp-p 150mVp-p 150mVp-p
6.8 ~ 9V ±2.0%
10.2 ~ 13.8V 13.5 ~ 18V
±1.0%
±1.0%
±0.5%
±0.3%
±0.3%
±1.0%
±0.5%
±0.5%
3600ms, 50ms/115VAC at full load
24V 27A 0 ~ 27A 648W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5%
36V 17.5A 0 ~ 17.5A 630W 200mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5%
48V 13A 0 ~ 13A 624W 240mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5%
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.99/115VAC at full load
INPUT
EFFICIENCY (Typ.)
78.5%
82%
86%
88%
88%
88%
89%
89%
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
7.6A/115VAC 3.6A/230VAC 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION DC OK SIGNAL FAN CONTROL (Typ.) WORKING TEMP.
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V Load 35±15% or RTH250 Fan on -40 ~ +70 (Refer to “Derating Curve”)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL62368-1, TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4)
EMC EMISSION
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
57.6 ~ 67.2V
EMC IMMUNITY MTBF
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level, EAC TP TC 020 1333.6K hrs min. Telcordia SR-332 (Bellcore) ; 140.7K hrs min. MIL-HDBK-217F (25)
OTHERS NOTE
DIMENSION
21810563.5mm (LWH)
PACKING
1.5Kg;8pcs/13Kg/1.34CUFT
http://www.meanwell.com) https://www.meanwell.com/serviceDisclaimer.aspx
File Name:HRP-600-SPEC 2022-08-08
600W Single Output with PFC Function
Mechanical Specification
152.4
20.75
10 8.2
Air flow direction
I/P 1 2 3
12max.
63.5
4-M4 L=6
218 152.4 8-M4 L=4 (Both Sides)
HRP-600 series
32.8
O/P 1 2 3 4 5 6
9.2
11
Case No. 977A Unit:mm
12 34
105
CN100 LED
SVR1 (Vo ADJ.)
32.8 18max.
12.5 38.3 63.5
AC Input Terminal Pin No. Assignment
Pin No. Assignment
1
AC/L
2
AC/N
3
FG
Block Diagram
I/P
EMI FILTER
FG
Derating Curve
DC Output Terminal Pin No. Assignment
Pin No. Assignment
1~3
-V
4~6
+V
Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent
Pin No. Assignment Mating Housing Terminal
1
DC-OK
2
GND
HRS DF11-4DS HRS DF11-**SC
3
+S
or equivalent or equivalent
4
-S
ACTIVE INRUSH CURRENT LIMITING
RECTIFIERS &
PFC
O.T.P.
PFC CONTROL
POWER SWITCHING
O.L.P.
PWM CONTROL
RECTIFIERS &
FILTER
DETECTION CIRCUIT O.T.P. O.V.P.
PWM fosc : 70KHz +S +V -V -S
DC OK
Output Derating VS Input Voltage
LOAD (%) LOAD(%)
125
100
100
90
80 80
70
50
60
50
20
40
-40
0
10
20
30
40
50
60 70 (HORIZONTAL)
85
100
125
135
155
264
AMBIENT TEMPERATURE ()
INPUT VOLTAGE (V) 60Hz
File Name:HRP-600-SPEC 2022-08-08