MEAN WELL SPV-300-24 Switching Power Supply, 24V dc, 12.5A Instructions
- June 3, 2024
- MEAN WELL
Table of Contents
MEAN WELL SPV-300-24 Switching Power Supply, 24V dc, 12.5A
Features
- Universal AC input/ Full range
- Built-in active PFC function, PF>0.95
- Protections: Short circuit/ Overload I Over voltage/ Over temperature
- Forced air cooling by built-in DC Fan
- Output voltage programmable from 20~110% by 1 ~5.5VDC external control signal
- Built-in remote ON-OFF control
- Built-in fan speed control
- Fixed switching frequency at 100KHz
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | SPV-300-12 | SPV-300-24 | SPV-300-48 |
---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 24V |
RATED CURRENT | 25A | 12.5A | 6.25A |
CURRENT RANGE | 0-25A | 0-12.5A | 0 – 6.25A |
RATED POWER | 300W | 300W | 300W |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 240mVp-p |
VOLTAGE ADJ. RANGE | 10.8-13.2V | 20- 26.4V | 41 -52.8V |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.3% | ±0.2% | ±0.2% |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 800ms , 50ms/230VAC 2500ms, 50ms/115VAC at |
full load
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.5| 88 – 264VAC 124 – 370VDC
FREQUENCY RANGE| 47 – 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 83.5%| 85%| 86.5%
AC CURRENT (Typ.)| 3.6A/115VAC 1.8A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC 45A/230VAC
LEAKAGE CURRENT| <1mA/240VAC
PROTECTION| OVERLOAD| 105 – 135% rated output power
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 13.8-16.2V| 27.6 – 32.4V| 57.6- 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| REMOTE CONTROL| 4 -1 OVDC power off, <O – O.BVDC power on
OUTPUT VOLTAGE TRIM| 2.4~13.2V| 4.8- 26.4V| 9.6 – 52.BV
ENVIRONMENT
| WORKING TEMP.| -20 – +65″C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85″C , 10 – 95% RH non-condensing
TEMP. COEFFICIENT| ±0 03%/°C (0 – 50°C)
SAFETY EMC (Note4)| VIBRATION| 10-500Hz, 2G 10min./1cycle,
60min. each along X, Y, Z axes
SAFETY STANDARDS| UL60950-1, TUV BS EN/EN60950-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-0/P 3KVAC 1/P-FG 2KVAC 0/P-FG 0.5KVAC
ISOLATION RESISTANCE| 1/P-0/P, 1/P-FG, O/P-FG:100M Ohms/ 500VDC I
25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2 ,3,4,5,6,8,11, BS
EN/EN55024 , light industry level, EAC TP TC 020
OTHERS| MTBF| 2116.3K hrs min. Telcordia SR-332 (Bellcore);
210.6K hrs min. MIL-HDBK-217F (25″C)
DIMENSION| 215’115’50mm (L’W’H)
PACKING| 1.1Kg; 12pcs/14Kg/0.92CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm’360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The ambient temperature derating of 3.5″C/1000m with fanless models and of 5’C/1000mwith fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
300W Single Output with PFC Function
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Function Manual
- External Voltage Control
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>