BUFFALO DB162 UV Knife Steriliser 14 Knife Capacity Instruction Manual

June 6, 2024
BUFFALO

Knife Steriliser
Instruction manualBUFFALO DB162 UV Knife Steriliser 14 Knife
Capacity Model: DB162

Safety Tips

  •  A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components on this product.

  • Consult Local and National Standards to comply with the following:
    – Health and Safety at Work Legislation
    – BS EN Codes of Practice
    – Fire Precautions
    – IEE Wiring Regulations
    – Building Regulations

  •  DO NOT immerse the appliance in water.

  • DO NOT clean with jet/pressure washers.

  • Not suitable for outdoor use.

  • DO NOT bypass the safety interlocks.

  • Always switch off and disconnect the power supply to the appliance before cleaning.

  •  DO NOT look directly at the lamp.

  • This appliance must only be used in accordance with these instructions and by persons competent to do so.

  •  Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.

  • If the power cord is damaged, it must be replaced by a BUFFALO agent or a recommended qualified technician in order to avoid a hazard.

  •  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.  Children should be supervised to ensure that they do not play with the appliance.

  •  BUFFALO recommends that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity, and Functional Testing.

  • BUFFALO recommends that this product be connected to a circuit protected by an appropriate RCD (Residual Current Device).

Product Description

DB162 – Knife Steriliser

Introduction

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your BUFFALO product.

Pack Contents

The following is included:

  • BUFFALO Knife Steriliser
  •  Instruction manual
    BUFFALO prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage.
    Should you find any damage as a result of transit, please contact your BUFFALO dealer immediately.

Installation

BUFFALO DB162 UV Knife Steriliser 14 Knife Capacity
-Installation

  • Ensure you have adequate support to support the appliance and proceed to drill and install the fixing screws.
  • Once the screws are installed, locate the appliance on the wall by aligning the locating holes on the backplate with the screws.

Warning: Ensure the substrate and fixings used to mount the Knife Steriliser are suitable to support the weight of the loaded unit.
If necessary, seek professional help to ensure the shelf is safely mounted.

Operation

  • Open the door, and put the Knives in the basket (Knives should be washed and dried before placing inside the sterilizer). Ensure that the knives are held in the rack with the blade facing upwards and angled towards the back of the unit. The handle of the knife should be resting on the floor of the unit behind the front lip.BUFFALO DB162 UV Knife Steriliser 14 Knife Capacity -Operation

  • Close the door.

  • Connect the appliance to the suitable mains supply and turn on the power supply.

  • There are 2 methods of operating the Knife Steriliser:
    Turn the timer dial to the” ON” position – the lamp will continue to operate until the door is opened or the timer is returned to the “OFF” position  ( Note : 120 minutes is the time required to ensure sterilization).
    To use the timer function rotate the dial to the 120-minute position. The unit will then operate for 120 minutes (Note: 120 minutes is the time required to ensure sterilization).

  •  A safety switch turns off the lamp when the door is opened.

  • DO NOT look directly at the lamp.

Cleaning, Care & Maintenance

  • Always turn OFF the appliance and disconnect from the power supply before cleaning.
  •  Warm soapy water is recommended for cleaning. Cleaning agents may cause damage or leave harmful residues when used for a prolonged period on stainless steel.
  •  Dry thoroughly after cleaning.
  •  A BUFFALO dealer or qualified technician should carry out repairs if required.

Troubleshooting

Fault

| Probable Cause|

Solution

---|---|---
Appliance not

working

| The unit is not switched on| Check the unit is plugged in correctly and

switched on

Plug and lead are damaged| Call BUFFALO agent or qualified Technician
Fuse in the plug has blown Power supply| Replace the plug fuse
Bulb has blown| Check power supply
The door is not shut correctly| Replace bulb (Bulb must have a light wavelength

of 253.7nm. Please contact your retailer)

The unit is not switched on| Shut the door

Technical Specifications

Model

| Voltage| Power| Dimensions

H x W x D mm

|

Weight

---|---|---|---|---

DB162

| 230V, 50Hz| 20W| 600 x 510 x 150| 7.5kg

Electrical Wiring
This appliance is supplied with a 3 pin BS1363 plug and lead.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:

  • Live wire (colored brown) to the terminal marked L
  • Neutral wire (colored blue) to the terminal marked N
  • Earth wire (colored green/yellow) to terminal marked E
    This appliance must be earthed.
    If in doubt consult a qualified electrician.
    Electrical isolation points must be kept clear of any obstructions. In the event of any emergency,
    disconnection is required they must be readily accessible.

Compliance

The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.BUFFALO parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent,  and federal authorities.
BUFFALO products have been approved to carry the following symbol: All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying,  recording, or otherwise, without the prior written permission of BUFFALO.
Every effort is made to ensure all details are correct at the time of going to press, however, BUFFALO reserve the right to change specifications without notice.

DECLARATION OF CONFORMITY

Equipment Type Model
Knife Steriliser DB162 ( & -E)
Application of erritory Legislation &   Council Directives(s) **Low

Voltage Directive (LVD) – 2014/35/EU**

EN 60335-1:2012 +A11:2014 +A12:2017

EN 62233:2008

EN 60335-2-27 Clause 32 – UV Test

Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU – recast of 2004/108/EC

EN 55014-1:2017 +A11:2020

EN 55014-2:2015

EN IEC 61000-3-2: 2019

EN 61000-3-3: 2013 +A1:2019

Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex II to Directive 2011/65/EU

Producer Name| Buffalo

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s), and Standard(s).

Date 19th  January 2021
Signature
Full Name Ashley Hooper
Position Technical & Quality Manager
Producer Address Fourth Way, Avonmouth, Bristol, BS11 8TB United Kingdom

North Point Business Park New Mallow Road Cork Ireland


UK +44 (0)845 146 2887

http://www.buffalo-appliances.com/

DB162_ML_A5_v3_20210125

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals