SDC Magnetic Lock E1200 Instruction Manual

June 6, 2024
SDC

Excel logoINST INSTRUCTION SRUCTIONS
E1200
MAGNETIC LOCK

SDC Magnetic Lock E1200

SDC Magnetic Lock E1200-

Electrical Instructions:

Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and residual magnetism to occur.
Although SDC recommends the use of a DC power supply, a transformer with an adjacent mounted full-wave bridge rectifier may be used. A significant drop will occur when using a full-wave bridge rectifier.
Any low voltage condition will cause erratic operation of the optional board sensor.
When using a full-wave bridge rectifier all access controls and/or release contacts must be located between the lock and rectifier to ensure a quick release.

Electrical Specifications:

Dual Voltage: 12 or 24VDC
Power Consumption: .505mA @ 12VDC

.260mA @ 24VDC
DS Door Status Senso| SPDT, 500mA @ 30VDC
LS Lock Status Sensor| SPDT, 2A @ 30VDC

SECURITY DOOR CONTROLS. WWW.SDCSECURITY.COM
[t] 800.413.8783 ,805.494.0622 ,E-mail: service@sdcsecurity.com ,
801 Avenida Acaso, Camarillo, CA 93012 , PO Box 3670, Camarillo, CA 93011

Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

  1. Inspect the frame header to determine if mounting accessories are required (refer to page 4).

  2. Fold template as indicated on the dotted line. For single doors locate the template against the door and header on the lock jamb side of the frame.

  3. Mark and drill holes as indicated by the template.SDC Magnetic Lock E1200-STEPS 2 & 3

  4. Mount armature to door.SDC Magnetic Lock E1200-STEP 4SDC Magnetic Lock E1200-HOLLOW METAL DOOR HOLLOW METAL DOOR
    From the Sexnut side of the door, drill exactly 1/2” hole thru one metal thickness only. From the Armature side of the door, drill a 5/8” hole to insert the reinforcement tube. Press in sex nut and reinforcement tube all the way and mount armature to door using hardware provided.

  5.  Install magnet onto the header with the magnetic stripes towards the door side of the stop.
    Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.SDC Magnetic Lock E1200-STEP 5

  6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the door. Tap with a soft hammer to ensure proper alignment and engagement.
    CAUTION : The lock body must be held in place until secured with mounting screws. Secure socket head screws are provided inside the housing at each end. Start screws into threads carefully to avoid stripping the threads. Check alignment and tighten screws. Pull wires through the frame, mounting plate, and magnet housingSDC Magnetic Lock E1200-STEP 6

  7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.
    SDC Magnetic Lock E1200-Test operation

  8. Test operation. When all is operating properly, tighten all screws as shown. Install security pins and screws as shown.  install antitamper plugs over socket head screws using a soft hammer to avoid damage to the housing.

MOUNTING ACCESSORIES:

Supplied Mounting Hardware

SDC Magnetic Lock E1200-Supplied Mounting Hardware

OPTIONAL MOUNTING HARDWARE:

SDC Magnetic Lock E1200-HARDWARE

To maintain surface plating from corrosion:

  • Do not touch the lock face with your hands.
  • Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper).
  • Apply a thin film of rust inhibitor (LPS-3) on the lock face.
  • Repeat application on armature plate.

P:\INST INSTRUCTIONS\EMLOCKS\INST-E1200 REV A.4 10-21

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals