Enbrighten ZW3107 Plug-in Smart Dimmer Instruction Manual
- June 6, 2024
- enbrighten
Table of Contents
Enbrighten ZW3107 Plug-in Smart Dimmer Instruction Manual
Additional Item
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have any problems or questions, contact our U.S.-based Consumer Care at
1-800-654-8483, option 1,
Monday–Friday, 7AM–8PM Central Time.
For the most up-to-date product support, accessories, electronic (PDF) format
manuals and more, visit
www.byjasco.com/support.
No user-serviceable parts in this unit.
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for five years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F, Central Time or www.byjasco.com if the unit should prove defective within the warranty period.
WARNING
- RISK OF FIRE
- RISK OF ELECTRICAL SHOCK
- RISK OF BURNS
- TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING-TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING-TYPE POWER OUTLET. IF THE PLUG DOES NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
- CONTROLLING APPLIANCES
- CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A MOTOR-OPERATED APPLIANCE, A FLUORESCENT LIGHTING FIXTURE OR A TRANSFORMER-SUPPLIED APPLIANCE.
- ONLY USE TO CONTROL INCANDESCENT OR DIMMABLE CFL/LED BULBS
- DO NOT EXCEED RATINGS
- DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
SPECIFICATIONS
- Power: 120VAC, 60Hz
- Signal frequency: 908.4/916MHz
- Total maximum load for both Z-Wave controlled outlet: 300W (2.5A) incandescent or 100W dimmable CFL/LED Z-Wave controlled outlet is fused @ 5A. This fuse is not user serviceable.
- Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module Operating temperature range: 32–104° F (0–40° C)
For indoor use only
Specifications subject to change without notice due to continuing product improvement
Getting to know your new Z-Wave device
Total maximum load for Z-Wave controlled outlets: 300W (2.5A) incandescent or 100W dimmable CFL/LED
- Two Z-Wave controlled AC outlets for standard incandescent lighting or dimmable CFL/LEDs
- Remote ON/OFF and brightness control via the Z-Wave controller
- Manual ON/OFF and brightness control with the top-mounted push button
Space-efficient design
Does not block the lower outlet when plugged into the upper outlet of a duplex
wall receptacle (assumes the duplex receptacle is mounted with the ground pin
down)
- Plugs and cords for connected devices route to the side allowing close placement of furniture
- This Z-Wave smart dimmer has advanced features that allow you to customize your experience — these features can only be adjusted by a Z-Wave enabled controller that supports the Z-Wave configuration command class. For a complete list of adjustable configurations, visit www.ezzwave.com/config
How to USE
-
A. Z-Wave controlled outlets
Both outlets are controlled together and can remotely turn ON/OFF and dim the connected lamp(s)* -
B. Manual/program button
Single press — turn the lamp(s) ON/OFF
Press and hold — dim/brighten the lamp(s)
Single press — add or remove in Z-Wave network -
C. Cycle LED light
The LED acts as a guide light or status indicator.
How to cycle through options: Press program button 10 times quickly.- LED is ON when the load is ON (indicates the dimmer is ON) (default)
- LED is ON when the load is OFF (guide light in the dark)
- LED is always OFF
- LED is always ON
-
Both outlets can only be controlled together. Cannot be independently controlled.
Step 1:
-
Plug a light into the Z-Wave controlled outlet on the smart dimmer.
-
Plug the smart dimmer directly into an available grounded outlet (top outlet recommended if possible).
NOTE: Plug directly into outlet. Do not use with extension cords.
Step 2:
The manual/program button on the dimmer allows the user to:
- Manually turn the connected lamp(s) ON or OFF (press and release).
- Adjust the brightness level of the connected lighting by pressing and holding the button. Release the button when the desired level is attained.
- Add/remove the smart dimmer from the network.
Step 3:
Adding your device to a Z-Wave network:
- Follow the instructions for your Z-Wave certified controller to add the smart dimmer to the Z-Wave network.
- Once the controller is ready to add your smart dimmer, single press and release the manual/program button on the smart dimmer.
You have complete control to turn your lamp ON/OFF or set dim levels according
to groups, scenes, schedules and interactive automations programmed by your
controller.
If your Z-Wave certified controller features remote access, you can control
your lighting from your mobile devices.
If prompted by the controller to enter the S2 security code, refer to the QR
code/security number on the side of the box or the QR code label on the
product (see Figure 1). Enter the 5-digit PIN code.
Please reference the controller’s manual for instructions.
To remove and reset the device:
- Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
- Once the controller is ready to remove your device, press and release the manual/program button on the smart dimmer
To return your dimmer to factory defaults:
- If plugged in, unplug the dimmer from the receptacle.
- Press and hold the top button for at least three seconds while you plug the dimmer into a receptacle.
- The LED will flash five times when completed successfully.
NOTE: This should only be used in the event your network’s primary
controller is missing or otherwise inoperable.
NOTE: SmartStart enabled products can be added
into a Z-Wave network by scanning the QR code on
the product with a controller providing SmartStart inclusion. No further
action is required and the SmartStart product will be added automatically
within 10 minutes of being switched on in the network vicinity.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications.
All non-battery-operated nodes within the network will act as repeaters
regardless of vendor to increase the reliability of the network.
This device supports Association Command Class (3 Groups) • Association
Group 1 supports Lifeline, Switch Multilevel Report, and Central Scene
Notification
- Association Group 2 supports Basic Set and is controlled with the local load
- Association Group 3 supports Basic Set and is controlled by double-pressing the button
- Each Association Group supports 5 total nodes
FCC/IC
This device complies with Part 15 of the FCC and Industry Canada license- exempt RSS standards. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in
a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void the user’s authority to operate the device.
Read User Manual Online (PDF format)