COSTWAY EP24456USA UV-C Fountain Pump User Manual

June 6, 2024
COSTWAY

USER’S MANUAL
UV-C Fountain Pump
EP24456US

THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ AND KEEP FOR FUTURE REFERENCE.

WARNING
Please read the operating instructions and familiarize yourself with the equipment before placing it in service. Correct and safe use of the system requires strict compliance with the safety instructions. For safety reasons children and young people under 16 years of age, as well as people that cannot recognize potential hazards or people that are not familiar with these instructions, may not use this device.

CAUTION
CUF is UV-C clarify equipment which can be combined. It contains water pump and one piece of UV-C lamp. Any damage on the equipment or unmerited operation will bring dangerous radiation to the skin and eyes. So if there is any damage of the equipment, it can not be used anymore. This equipment is not intended for use by person (including children) with reduced physical, sensory of mental capabilities, or tack of experience and knowledge unless they have been given supervision or instruction concerning use of the equipment by a person responsible for their safety. The equipment should be placed out of children reach. For the consideration of security, people under 16 years old and those who can not identify danger or grasp the instruction can not use the equipment.

  1. This equipment should be placed under the water. Be sure the equipment is submerged completely in the water and the depth should not be greater than 2m.
  2. When the water is not enough to submerge the equipment, please never connect power of the equipment to avoid running without water and causing damage .
  3. As the UV-C lamp is made of quartz glass, please avoid drap of it or wallop on it.
  4. Before all parts, are installed completely, the equipment can not be plugged in.
  5. If there is any damage on the power cable, UV-C lamp, or shell, the equipment can not be used. And it should be discarded as useless.
  6. Please make sure that the electrical voltage, frequency used are consistent with the indication on the label of the equipment.
  7. When installing the equipment, the installation regulation of pond pumps should be followed.
  8. The equipment should be earthed. And the professional person should check the condition of earthed. For the considered of safety, we advise customer to install leakage Protector.
  9. Pull the connecting cable is forbidden. And please keep the connecting cable away from heat, greasiness or sharpness.
  10. When the pump having any unusual noise, please unplug to check the reason.
  11. When knowing the frost is coming, please move away UV-C filter to avoid frost crack.
  12. The dirtiness on the quartz glass tube will influence the effect of the equipment, please clean the quartz glass tube in time.
  13. When the body shell is blocked with the sands and rubbish, it is possible to destroy the quartz glass tube and water pump. So please add the filter sponge to the inlet of the water, And the sponge should be cleaned timely. (once a month).
  14. UV-C is harmful to the eyes and skin. Please do not watch UV-C directly or let the skin approach to the UV-C.
  15. When installing or repairing this equipment, the electrical source of the equipment must be switched off.

INSTRUCTION

  1. This equipment has built-in filter sponge, biochemical basket, UV-C lamp and water pumps. This equipment adopts reasonable water channel, suitable for both indoor, outside pond garden, aquatic breeding, clean water sterilization and water fountains.
  2. Through the working of water pump, water flow from the filter cover to filter sponge, and then to the UV-C lamp. Inside of the UV-C lamp, the harmful  bacteria and algae will be killed. Then the water flow to outside finally.
  3. The UV-C lamp was designed as a closed device, no UV-C will scattering. And UV- C light 253.7nm will kill the harmful bacteria and algae to keep a good  condition of water.

FEATURES

  1. This product contents filtration, biochemical bacteria culture, sterilization, pumping, fountain and other functions all in one, and the structure is reasonable and
    compact.

  2. Large filter surface, reasonable water flow channel and the effect is remarkable.

  3. Built-in independent filter material box for easy replacement and adding different biochemical filter materials, (Apple for specific models, please refer to the product structure for specific models)

  4. CUF-2800 series, the middle of the water filter can be stacked (sold separately) to extend the maintenance cycle.

  5. Suitable for ponds.

TECHNICAL PARAMETER

Model Voltage Power UV-C Power H-max Output House Adapter Weight
CUF-2505 220-240V/50Hz
110-120V/6011z 24W 5W 1.6m 1000L/h ½” ∼ ¾”∼¹ 3.7kg
CUF-5005 38W 5W 2.0m 2000L/h -½” ∼ ¾”∼¹ 4.0kg
CUF-6005 50W 5W 2.5m 2500L/h ½” ∼ ¾”∼¹ 4.2kg
CUF-2500 220-240V/50Hz
110-120V/60Hz 28W 9W 1.6m 1000L/h ½” ∼ ¾”∼¹ 4.7kg
CUF-5000 42W 9W 2.0m 2000L/h ½” ∼ ¾”∼¹ 5.0kg
CUF-6000 54W 9W 2.5m 2500L/h ½” ∼ ¾”∼¹ 5.2kg
CUF-2511 220-240V/50Hz 30W 11W 1.6m 1000L/h ½” ∼ ¾”∼¹ 5.4kg
CUF-5011 45W 11W 2.0m 2000L/h ½” ∼ ¾”∼¹ 5.7kg
CUF-6011 57W 11W 2.5m 2500L/h ½” ∼ ¾”∼¹ 5.9kg
CUF-2511 110-120V/60Hz 32W 13W 1.6m 1000L/h ½” ∼ ¾”∼¹ 5.4kg
CUF-5011 47W 13W 2.0m 2000L/h ½” ∼ ¾”∼¹ 5.7kg
CUF-6011 59W 13W 2.5m 2500L/h ½” ∼ ¾”∼¹ 5.9kg
CUF-2800 220-240V/50Hz 30W 11W 2.0m 3000L/h ¾”∼¹ 6.5kg
CUF-3800 35W 11W 2.8m 3600L/h ¾”∼¹ 6.5kg
CUF-4800 45W 11W 4.0m 4500L/h ¾”∼¹ 6.5kg
CUF-5800 55W 11W 4.8m 5200L/h ¾”∼¹ 6.5kg
CUF-2800 110-120V/601-lz 30W 13W 2.0m 3000L/h ¾”∼¹ 6.5kg
CUF-3800 35W 13W 2.8m 3600L/h ¾”∼¹ 6.5kg
CUF-4800 100-120V/60Hz 45W 13W 4.0m 4500L/h ¾”∼¹  6.5kg
CUF-5800 55W 13W 4.8m 4800L/h ¾”∼¹  6.5kg

PART LIST

CUF-2800/3800/4800/5800

1 Nozzle 6 Outlet 11 Sponge 16 Lower filter cover 21 Screw
2 Flexible tube 7 Outlet nut 12 Middle filter cover 17 Motor 22

Quartz glass tube
3| Nut| 8| vviWnektsell’albn| 13| 0-ring 1| 18| Partition 1| 23| 0-ring 2
4| T-joint| 9| Upper filter cover| 14| Curved joint| 19| Partition 2| 24| tQjerlfi glass
5| Gasket| 10| Connection thread| 15| Filter material| 20| UV light shell body| 25| W-C device head with cat*

CUF-2500/5000/6000

1 Outlet 9 Filter base 17 0-ring
2 Elbow pipe 1 10 Adapter 18 Connection pipe 1
3 Filter cover 11 Water pump 19 Nut
4 Sponge 12 Fountain head 1 20 Flange
5 UV-C lamp 13 Fountain head 2 21 T-joint
6 Elbow pipe 2 14 Fountain head 3 22 Screw
7 Filter material boxes 15 Fountain sets base
8 Runner plate 16 Connection pipe 2

CUF-2505/5005/6005

1 Outlet 8 Filter base 15 Fountain sets base
2 Elbow pipe 1 9 Bio-cell 16 Extention pipe
3 Filter cover 10 Gravel 17 Nut
4 Sponge 11 Water pump 18 Flange
5 UV-C lamp 12 Fountain head 1 19 T-joint
6 Elbow pipe 2 13 Fountain head 2
7 Cover plate 14 Fountain head 3

CUF-2511/5011/6011

1 Outlet 8 Filter material boxes 15 Nut
2 Elbow pipe 1 9 Runner plate 16 Connection pipe
3 Filter cover 10 Filter base 17 Fountain sets base
4 Clip 11 Adapter 18 Fountain head 1
5 Sponge 12 Water pump 19 Fountain head 2
6 UV-C lamp 13 T-joint 20 Fountain head 3
7 Elbow pipe 2 14 Flange

1| UV light shell body| 6| Quart glass tube sleeve
2| Spiral sleeve| 7| 60×3.1 0-ring
3| Quartz glass tube| 8| UV-C lamp
4| Fixing nut| 9| UV-C device head with cable
5| 45×4 0-ring| 10| Safety buckle

1 Impeller cover
2 Rubber bearing
3 Rotor
4 O-ring
5 Shaft
6 Motor

INSTALLATION AND MAINTENANCE

Please switched off the electrical power when you clean the inside or change the UV-C lamp. When clean the inside or change the UV-C lamp, please take below part list as your reference.

INSTALLATION
After assembling the fountain parts according to the structure diagram, adjust the extension tube to the appropriate height and immerse the equipment under the water. If you need to pump clean water, you can remove the fountain assembly and install the water outlet pipe for using.

MAINTENANCE
MAINTENANCE FOR FILTER SPONGE AND FILTER MATERIAL:

  1. Take of the fountain parts, and open the two clips on the side of the filter cover, then you can open the filter cover.
  2. Take out the filter sponge and filter material(boxes), clean or change these. (suggest cleaning the filter sponge every week)

MAINTENANCE FOR UV-C LAMP

  1. 0pen the pump, remove the UV-C lamp from the pump, open the safety buckle, and rotate the lamp head counterclockwise to remove the quartz glass tube assembly. At this time, the UV-C lamp can be replaced (the CUF-2800 series does not need to open the pump, rotate the lamp head directly counterclockwise o remove).
  2. If you want to clean the quartz glass tube, remove the fixing nut and take it out for cleaning.

MAINTENANCE FOR WATER PUMP

  1. Rotate the impeller cover counterclockwise to the stuck position and open it outward to separate the impeller cover from the pump body.
  2. Remove the rotor and clean all parts with the small brush.

STORAGE IN WINTER

  1. Take out the equipment from water.
  2. Clean the equipment thoroughly.
  3. Check the parts and conditions of the equipment.
  4. Keep this equipment in an area that free from frost. And in a container that with clean water.

EASILY BROKEN PARTS

  1. UV-C lamp.
  2. Filter materials (bio-ball, gravel, filter sponge).

TROUBLE SHOOTING

TROUBLE REASON SOLUTION
Water pump not work •No power

•Burn
•Impeller block| •Plug in
•Change water pump
•Clean the blocks
Water pump noisy| •Something blocked in the impeller room
•Rotor or shaft wear and tear| •Open the water pump and clean the blocks
•Change the rotor or shaft
Water pump lack of water| •Impeller broken or water flow valve closed
• Equipment inlet blocked or water pump inlet blocked
• Lower voltage than requested| •Change the impeller set or open the water flow valve
•Clean the blocks
•Use suitable voltage
UV-C lamp not work| •No power
•UV-C lamp broken
•Connection of the UV-C lamp not good| •Plug in
•Change UV-C lamp
•Re-place the UV-C lamp

GUARANTEE

Note: This warranty card is for further quality information from you and timely service from our company.

  1. This card is to ensure quality service for products of our company.
  2. The warranty term is 1 year, valid from the date of the sales invoice (also the date of purchase), and fill the date onto this card.
  3. Quick-ware parts of the pump are beyond the scope of guarantee.
  4. The damage caused by incorrect use or the contrived damage will be exempted.

Warranty Registration Form
You Must Fill In All For Warranty Validation.

WARRANTY CARD

Model No.| | Date of purchase|
---|---|---|---
User| | Address|
Zipcode| | Phone| | Contact person|
Retailer| | |
Maintenance Records

Y M D

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals