In-Wall Smart Outlet Z-Wave’ certified
wireless lighting controlenbrighten ZWA1003 Z Wave In Wall Tamper
Resistant Smart Outlet 58449
ZWA1003

ADDING YOUR DEVICE TO A Z-WAVE NETWORK

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
  2. Once the controller is ready to add your device, press the program button.
    You have complete control to turn ON/OFF the smart outlet according to groups, scenes, schedules and interactive automation programmed by your controller.
    If your Z-Wave certified controller features remote access, you can control your outlet from your mobile devices.
    If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product (see Figure  1). Enter the 5-digit code.
    Figure 1:

https://byjasco.com/HEP-ET/20000-99999/39339

DSK : XXXXX : 25651-22671 26939-47599  19612-25872 47752

TO REMOVE AND RESET THE DEVICE

  1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
  2. Once the controller is ready to remove your device, press the program button.
    TO RETURN TO FACTORY DEFAULTS
    Press the program button five times, then, press and hold the button for at least three seconds. The LED blinks five times to confirm.
    NOTE: This should only be used if your network’s primary controller is missing or otherwise inoperable.
    NOTE: SmartStart-enabled products can be added to a Z-Wave network by scanning the QR code on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

SPECIFICATIONS — ARE IMPORTANT!

ZWAIOO3
Power: I25VAC, GOHZ
Signa frequency: 908.4,/91IGMHz
Operating temperature range: 52-104° F (0-40° C)
Total max load for both out ets: 1875W CSA) resistive load
Max load for Z-Wave controlled outlet:
IOOOW incandescent
lY2HP motor
1875W (ISA) resistive load
4.0A CELLED
Specify cations are subject to change without notice due to continuing product improvement

FEATURES

IMPORTANT! The fixture controlled by the Z-Wave smart outlet must not exceed outlet ratings.
Get to know your smart outlet

  • One Z-Wave-controlled outlet
  • One always-ON outlet
  • Turn ON/OFF manually or through the Z-Wave controller
  • Can be added in multiple groups and scenes
  • Configurable LED indicates outlet status when turned on
  • Screw terminal installation – requires wiring connections for line Chot), neutral and ground
  • This Z-Wave device has advanced features that allow you to customize your experience. These features can only be adjusted by a Z-Wave-enabled controller that supports the Z-Wave configuration command class. For a complete list of adjustable configurations, visit www.ezzwave.com/config

enbrighten ZWA1003 Z Wave In Wall Tamper Resistant Smart Outlet - fig
5

A. Line Chot)
B. Neutral (white)
Cc. Ground (green/bare)
D. Always-ON outlet
E. Manual/program button
F. Z-Wave controlled outlet Z-WAVE INTEROPERABILITY m
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.

This device supports association command class (3 Groups)

  • Association Group 1 supports Lifeline, Binary Switch Report
  • Association Group 2 supports Basic Set and is controlled by pressing the ON or OFF button with the local load
  •  Association Group 3 supports Basic Set and is controlled by double pressing the ON or OFF button
  •  Each Association Group supports 5 total nodes

All brand names shown are trademarks of their respective owners
MADE IN CHINA
Distributed by Jasco Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114.
This Jasco product comes with a 5-year limited warranty. Visit www.byjasco.com for warranty details.
Questions? Contact our U.S.-based Consumer Care at 1-800-654-8483 7 AM-8 PM, M-F, Central Time.
©JASCO 2022 | ZWAIOOS | 58449 | 07/14/22 v1

WARNING — SHOCK HAZARD

Turn OFF the power to the branch circuit for the outlet at the service panel. All wiring connections must be made with the power OFF to avoid personal injury and damage to the outlet. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation, consult a qualified electrician.

CHANGE FACEPLATE

This step is optional. Before installation, you may want to change the faceplate to match your wallplate or décor.

  1. Push the edge of the faceplate to slide it to the right.
  2.  Align the new faceplate with the grooves on the front of the receptacle and slide it into place.

WARNING – Use only replacement part (WFD1001-RC) with receptacle (Jasco Products Company, Model ZWA1003).
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. Do not use this replacement part with any receptacle other than the one specifically marked on the packaging and in these instructions.

REMOVE OUTLET

  1. Shut off power to the circuit at the circuit breaker or fuse box.
    IMPORTANT! Verify power to switch box is OFF before continuing.

  2. Remove wallplate.

  3.  Remove the outlet mounting screws.

  4.  Carefully remove the outlet from the electrical box – DO NOT disconnect the wires.

  5. Identify the following three wires in the electrical box:
    A. Ground – Green/bare
    B. Line (hot) – Black (connected to power)
    C. Neutral – White

  6. Disconnect the wires from the existing outlet – label wires according to the previous terminal connections.

INDICATOR LED

The indicator LED acts as a guiding light or status indicator.
How to cycle through options:
Press the program button five times to cycle through the options in the following order:

  1. LED ON when the load is ON (default)
  2.  Always OFF
  3.  Always-ON

enbrighten ZWA1003 Z Wave In Wall Tamper Resistant Smart Outlet - fig
4

Z-WAVE OUTLET WIRING

WIRING REQUIREMENTS
Attach using the enclosure’s holes, strip insulation 5/8in. (6mm).
Tighten screws to I2ibf-in. d4kgf-cm).
IMPORTANT! The screw terminals in this receptacle are intended for only copper wire. Consult a qualified electrician if you have aluminum wiring.
Use 14 or 12AWG wire suitable for at least 90° C for supplying line (hot), neutral, and ground connections.

  1. Connect green/bare wire to the GROUND terminal.
  2. Connect the black wire from the power source (hot) to the LINE terminal.
  3. Connect the white wire to the NEUTRAL terminal – use a jumper if necessary.
  4. Secure the smart device into the electrical box with the provided mounting screws – ensure wires are not pinched or crushed
  5. Install the wallplate.
  6. The blue indicator LED flashes twice per second for up to 10 minutes to indicate the device is in pairing mode.

enbrighten ZWA1003 Z Wave In Wall Tamper Resistant Smart Outlet - fig
2

Thank you for your purchase!
Instructions made easy Read instructions or watch the easy-to-follow videos.

enbrighten ZWA1003 Z Wave In Wall Tamper Resistant Smart Outlet - qr
codeScan code or visit byjasco.com/584439i

Register your product Receive exclusive deals and register your product.

enbrighten ZWA1003 Z Wave In Wall Tamper Resistant Smart Outlet - qr code
1Scan code or visit byjasco.com/deals.

For additional Enbrighten products, visit our website www.byjasco.com.

| Like our product?
Leave a review on your favorite retailer website or amazon.com.
---|---
| Having problems?
Let us know how we can help.
Call 1-800-654-8483 between 7 AM-8 PM, M-F, Central Time.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

enbrighten User Manuals

Related Manuals