ROBUS RHL1040P-04 Hilume LED Flood Light with PIR Instruction Manual
- June 6, 2024
- ROBUS
Table of Contents
HILUME LED FLOOD LIGHT
WITH PIR, IP65,
4000K, BLACK, C/W 1M FLEX
RHL1040P-04 RHL2040P-04
RHL3040P-04 RHL5040P-04
|
---|---
|
|
PLEASE READ THE INSTRUCTIONS BEFORE COMMENCING INSTALLATION AND RETAIN THEM
FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If
in any doubt about the installation or use of this product, consult a
competent electrician
Note:
Product technical information and specification may change over time
without prior notification. For the latest technical information please visit
our web sitewww.robus.com or
robusdirect.com
-20°C < Ta < +40°C, 220-240V ~ 50/60Hz, Class I, IP65
Luminaire is non-dimmable
Installation
- Ensure mains supply is switched off before commencing work.
- Select a suitable location for the luminaire.
- Mark wall with appropriate fixing positions. Before drilling, ensure that the hole does not impinge on pipework, cables, or other building services.
- Attach luminaire and fix bracket by tightening screws, then adjust to the desired angle. Ensure that it is secure.
- The luminaire is supplied with 1m of rubber cable. Using suitable IP-rated enclosure terminate Brown (Live), Blue (Neutral), and Green/Yellow (Earth) to switch suppliers.
Note: No “fixings screws provided’, please use appropriate fixing screws.
Walk testing can then be carried out to determine the detection area with a
slow walking pace.
Set time to a minimum, lux, and detection control to maximum. Once the
detector function has been established, change controls to desired levels.
When the sensor detects movement (Detection angle 120°, Detection distance
max 10m), the fitting will be switched on for the pre-set time. To increase on
time, turn time control towards +. Time delay range: from 10 seconds to 10
minutes. Daylight control range: 2 – 2000 Lux.
Note: Once the sensor has been triggered, subsequent detection restarts
the timing period from the beginning, so the light stays on until set time
elapses after last triggering.
Manual Override: It is possible to turn the sensor “On” for 8 hours by 3 “ON”
operations of the external switch within 3 seconds. It is possible to turn the
sensor back to AUTO mode (normal mode) by turning the fitting off for 10
seconds or more Market Surveillance:
These products contain light sources of energy efficiency as detailed below.
RHL1040-LS Class E, RHL2040-LS Class F
RHL3040-LS Class F, RHL5040-LS Class F
Remove the diffuser by removing screws on the back. Expose LED PCB
Information for the Product user:
- Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with crossed-out wheelie bin symbol).
- Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
- This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is separated from normal household waste and recycled in the WEEE chain
- The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be disposed of according to local WEEE regulations
The Installation must be carried out by a qualified electrician
L.E.D lighting & Electrical Distribution Group UC
Tel: +353 1 7099000
Fax: +353 1 7099060
Email: info@robus.com
Website: www.robus.com
Read User Manual Online (PDF format)