Dental Direkt Ti-Base 2CUT noLock Set
Contents:
1 x DD Ti-Base 2CUT noLock (titanium bonding base, can be shortened, non-
engaging)
1 x DD Lab Screw, blue
1 x DD Implant Screw, silver
Product description:
The Dental Direkt Ti-Base 2CUT noLock is used as a titanium bonding base for customized bridge and bar restorations. The titanium bonding bases are available for various implant systems and consist of a prefabricated implant interface, a screw channel, a circumferential platform for shaping the emergence profile and a cylinder that can be shortened for customized patient care. Dental Direkt titanium bonding bases are made of Ti6AI4V (medical grade 5) for single use and are supplied non-sterile, each with a separately packaged Implant and Lab Screw.
Caution: Dental Direkt titanium bonding bases must only be used in combination with the DD Implant Library.
Intended purpose:
DD Solid Connect® implant components are used to support prosthetic restorations in combination with endosseous dental implants in the upper and/or lower jaw.
Indication:
For attachment of customized bridge and bar restorations.
Contraindication:
- Intolerance to the constituents
- Restorations with an angulation correction of more than 25° to the implant axis
Please note : Observe the contraindications specified by the original implant manufacturer used in each case.
Intended users:
DD Solid Connect® implant components should only be used by dentists and dental technicians in compliance with the procedures in the instructions for use.
Intended patient group:
Fixed restorations using Dental Direkt Solid Connect® implant components are suitable for the permanent dentition in adult patients of any gender and nationality.
Instructions for use in the laboratory:
In the laboratory, the technician selects the DD Ti-Base 2CUT noLock that corresponds to the implant to be placed (see table). DD Ti-Base 2CUT noLock is supplied with a chimney height of 6 mm. The chimney height can be shortened at predefined grooves to a height of 5 mm or 4 mm by using a 0.3 mm thick fabric- reinforced cutting disc. The geometry of the titanium bonding base must not be altered in any way except for shortening the chimney height and removing the burr from the edges. Always use an extraction system when cutting and sandblasting. Metal dusts are harmful to health, so always wear respiratory protection and safety goggles. During subsequent fabrication of prosthetic restorations, the minimum wall thickness specified by the material manufacturer must be observed.
The individual restoration is constructed using dental design software. It is
possible to veneer a ceramic abutment using suitable veneering materials and
following the manufacturer‘s instructions. Veneering must always be completed
before bonding. The bonding surfaces of the titanium bonding base must be
treated with Al₂O₃ abrasives 110 μm and 2 bar max. before bonding. The
surfaces are bonded with a suitable luting material (e.g. Multilink® Hybrid
Abutment) in accordance with the manufacturer’s instructions. After curing,
all adhesive residues on basal surfaces and in the screw channel must be
carefully removed. The titanium bonding base must not display any sign of
damage. An undamaged and correct implant interface is essential for correct
placement of the prosthetic restoration.
Caution: On the model, only use the Lab Screw (max. torque: 10 Ncm).
Instructions for use in the dental practice:
The customized prosthetic restoration is placed in the patient’s mouth using
the silver Implant Screw. In the case of long-span bridge restorations, care
must be taken to ensure that the screw connections are free of stress. To
avoid any stresses, the implant screws are tightened diagonally.
Caution: The Lab Screw must not be used for placement of the implant
components in the patient’s mouth.
Caution: The Implant Screw must be tightened to the torque specified for
the system (see table).
Please note: It is recommended to tighten the Implant Screw 10 minutes
after placement.
Please note: When DD Solid Connect® implant components are used for
restorations with reduced-diameter implants, limited indications apply.
These can be found in the relevant instructions for use from the implant
manufacturer.
Please note: DD Solid Connect® implant components from a particular
series can only be combined with the corresponding compatible implant system.
This also applies to the corresponding platform diameters.
Material:
DD Ti-Base 2CUT noLock, DD Implant Screw and DD Lab Screw are all made of Ti6Al4V (medical grade 5) ASTM 136 ELI.
Cleaning, disinfection and sterilization:
DD Solid Connect® implant components and accompanying screws are cleaned at Dental Direkt, but not sterilized, before being packaged. After customizing, and before being used on the patient, the implant components must be cleaned, disinfected and sterilized following the procedure described by Dental Direkt.
Cleaning/disinfection:
Automatic cleaning in a suitable washer-disinfector with an appropriate
cleaning program for medical instruments (e.g. “Vario TD Program”, Miele).
OR
The following manual cleaning procedure:
- Rinse with cold tap water for 1 minute
- Rinse the screw channel using a disposable syringe (min. capacity 10 ml)
- Clean in the ultrasonic cleaner at 60°C (140°F) +/- 2°C, e.g. using Dr. Weigert neodisher® LM 2 for 10 minutes at a concentration of 5%
- Neutralize with cold distilled water for 2 minutes
- Rinse in the ultrasonic cleaner using distilled water at 60°C ( 140°F) for 10 minutes
Sterilization:
Double-seal products in sterilization film conforming to EN ISO 11607-1.
Steam sterilize in a suitable sterilizer with 3x fractionated prevacuum: 134°C
(273°F) for 5 minutes, drying time: 20 minutes. Then store in sterile
packaging.
Caution: DD Ti-Base 2CUT noLock, DD Implant Screw and DD Lab Screw are
suitable for single use only. Any reuse may lead to hazards due to infection.
Possible side effects and interactions:
Allergic reactions or skin irritations are possible in very rare cases.
Different alloys in the oral cavity can lead to galvanic reactions when in
direct contact.
Disposal:
In compliance with local regulations.
Warranty:
Our products undergo strict quality control and conform to the latest
technical standards. Please refer to our current warranty terms for further
details.
Please note: Any serious incident that occurs in connection with the
product should be reported to the manufacturer and the competent authority of
the Member State in which the user and/or patient is located
Please note: The safety and clinical performance summary report can be
requested at info@dentaldirekt.de.
We are continuously developing and enhancing our devices, and therefore reserve the right to make changes.
The latest version of the instructions for use can also be found on our website at: www.dentaldirekt.de/en
This version replaces all previous versions.
Explanation of symbols:
- Manufacturer
- Date of manufacture
- Batch code
- Catalog number
- Keep dry
- Non-sterile
- Do not use if package is damaged
- Torque
- Consult electronic instructions for use www.dentaldirekt.de/IFU
- Caution: Under U.S. federal law, the device may only be sold by or on behalf of a dentist.
- Do not re-use
- Medical device
- Unique device identification
SPECIFICATIONS
Dental Direkt Series| Compatible with: manufacturer|
System| Size (mm)| Torque (Ncm)
---|---|---|---|---
DD AAS-Serie| Dentsply Implants®| Astra Tech®| 3,5 / 4,0| 25
4,5 / 5,0| 25
DD BSK-Serie| Bredent| Sky®| 3,5 NP| 25
4,0 / 4,5 RP| 25
DD CCA-Serie| Camlog®| Camlog®| 3,3| 20
3,8| 20
4,3| 20
5,0| 20
DD CCO-Serie| Camlog®| Conelog®| 3,3| 20
3,8| 20
4,3| 20
5,0| 20
DD DEV-Serie| Dentsply Implants®| Astra EV| 3,0| 25
3,6| 25
4,2| 25
4,8| 25
5,4| 25
DD DFX-Serie| Dentsply Implants®| Frialit®/Xive®| 3,4| 25
3,8| 25
4,5| 25
5,5| 25
DD MAR-Serie| MegaGen| AnyRidge®| 3,5 – 6,0| 30
DD MMI-Serie| Medentis Medical®| ICX| 4,1| 30
DD MSE-Serie| MIS Implants®| Seven®| 3,3 NP| 30
4,2 SP| 30
5,0 WP| 30
DD NBR-Serie| Nobel Biocare™| Brånemark| 3,5 NP| 35
4,1 RP| 35
DD NNA-Serie| Nobel Biocare™| Nobel Active™| 3,5 NP| 25
4,3 / 5,0 RP| 35
DD NRE-Serie| Nobel Biocare™| Replace Select®| 3,5 NP| 35
4,3 RP| 35
5,0 WP| 35
DD OTS-Serie| Osstem Implant| TS| 3,5 M| 20
4,0 – 6,0 R| 20
DD SBO-Serie| Straumann| Bone Level®| 3,3 NC| 35
4,1 / 4,8 RC| 35
DD SSY-Serie| Straumann| synOcta®| 4,8 RN| 35
6,5 WN| 35
DD TSP-Serie| Thommen Medical| SPI®| 3,5| 15
4,0| 25
4,5| 25
5,0| 25
6,0| 25
DD ZBC-Serie| Zimmer Biomet 3i| Certain®| 3,4| 30
4,1| 30
5,0| 30
DD ZTA-Serie| Zimmer Dental| Tapered Screw- Vent®| 3,5| 30
4,5| 30
5,7| 30
Dental Direkt GmbH · Industriezentrum 106 – 108 · 32139 Spenge · Germany · Tel.: +49 5225 863190 7 eIFU_DD Ti-Base 2CUT noLock_Rev.07_20230510
References
- Dental Direkt - close to you
- Dental Direkt - close to you
- Your search results | Dental Direkt
- Downloads | Dental Direkt
- Validated Milling Centers - Dental Direkt
- eIFU - electronic Instructions for Use | Dental Direkt
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>