OKIN CB3433A Control Box Instructions
- June 6, 2024
- OKIN
Table of Contents
OKIN CB3433A Control Box
Electrical configuration diagram:
Function Picture
Interface function description
HEAD ACTUATOR
Connect to head actuator, control by a remote single:
Click head-up button on the remote, head actuator moves out, stop when
released;
Click the head down button, the head actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
FOOT ACTUATOR
Connect to foot actuator, control by a remote single:
Click foot up button, foot actuator moves out, stop when released;
Click foot down button, foot actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
LUMBAR ACTUATOR
Connect to foot actuator, control by a remote single:
Click Lumber up button, foot actuator moves out, stop when released;
Click Lumber down button, foot actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the
remote.
HEAD1 VIBRATION & HEAD2 VIBRATION
Connect to head massage, control by remote:
Click head massage + button, head massage strengthens by one level;
Click head massage – button, head massage weaken by one level;
This function takes effect only by pressing the corresponding button on the
remote.
FOOT VIBRATION
Connect to Foot massage, control by remote:
Click FOOT massage + button, head massage strengthens by one level;
Click FOOT massage – button, head massage weaken by one level;
This function takes effect only by pressing the corresponding button on the
remote.
Power LED & PAIRING LED
Power supply for control box, PAIRING LED of the control box is blue, POWER
LED is green。
PAIR & RESET button Function
Pair Function:
Power supply for control box, Pair LED lights to blue, the control box enters
into the mode of code paring;
Press and hold the pairing button of Remote, the backlight of paring LED
flashes, the backlight of remote flashes, the remote enters into the mode of
code paring;
The backlight of paring LED of remote stops flashing, and the paring led of
control box turns off, it indicates that the code paring is successful;
If fails, repeat all the processes above;
SYNC port
Connect with the same other Control box or Other accessories;
under bed light-RGB
Click the button of the under bed light, turns on(or change) the under bed
light, switch the status once when clicking once; This function takes effect
only by pressing the corresponding button on the remote.
USB Power OUT
Connect USB panel
UART1 port & UART2 port
Connect other serial peripherals
Power
Connect to the 29V DC;
FCC Warning
Please take attention that changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
ISED RSS Warning:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>