OKIN REFINED RF5022 Refined Electric Remote Control Instructions
- June 6, 2024
- OKIN REFINED
Table of Contents
OKIN REFINED RF5022 Refined Electric Remote Control
Item
NO. | product name | Product code | number |
---|---|---|---|
1 | Head Motor | B.15055 | 1 |
2 | Foot Motor | B.11964 | 1 |
3 | Lumbar Motor | JLDQ.16.263.84 | 1 |
4 | Tilt Motor | JLDQ.16.228.31 | 1 |
5 | Massage Motor | JLDQ.9.001.130C | 2 |
6 | Massage Motor Cable | R5.410.01.009 | 1 |
7 | Control Box | CB.13.42.01 | 1 |
8 | Power Supply | JLDP.10.023.000 | 1 |
9 | cord of Power | R5.217.01.016 | 1 |
10 | Power Cord AC | R5.504.01.250 | 1 |
11 | Y-Cable | R5.216.01.015C | 1 |
12 | Patch cord of LED strip/LED | R5.413.01.005 | 1 |
13 | Underbed lighting /LED | R5.113.00.011 | 1 |
14 | USB Chager/ USB | JLDP.05.032.000 | 1 |
15 | Double USB socket | JLDP.14.027.000 | 2 |
16 | 22keys Remote Model /22 | RF3022A | 1 |
Buttons
-
ZG button
Click the ZG button, the actuator moves to ZG position, stop when click any button during the movement;
Press and hold the ZG button for 5s, timer LED of remote flashes, the control box records current position as ZG position;
When in the process of moving to memory positions, the head and foot actuators move first, then the tilt and lumbar actuators move; -
M1 nitton
Click M1 button, actuators move to M1 position, stop when click any button during movement;
Press and hold M1 button for 5s, timer LED of remote flashes, the control box records current position as M1 position;
When in the process of moving to memory positions, the head and foot actuators move first, then the tilt and lumbar actuators move; -
AntiSnore button
Click AntiSnore button, actuators move to AntiSnore position, stop when click any button during movement;
Press and hold AntiSnore button for 5s, timer LED of remote flashes, the control box records current position as AntiSnore position;
When in the process of moving to memory positions, the head and foot actuators move first, then the tilt and lumbar actuators move; -
TV/PC button
Click TV/PC button, actuators move to TV/PC position, stop when click any button during movement;
Press and hold TV/PC button for 5s, timer LED of remote flashes, the control box records current position as TV/PC position;
When in the process of moving to memory positions, the head and foot actuators move first, then the tilt and lumbar actuators move; -
M2 button
Click M2 button, actuators move to M2 position, stop when click any button during movement;
Press and hold M2 button for 5s, timer LED of remote flashes, the control box records current position as M2 position;
When in the process of moving to memory positions, the head and foot actuators move first, then the tilt and lumbar actuators move; -
LOUNGE button
Click the LOUNGE button, actuators move to LOUNGE position, stop when click any button during movement;
Press and hold LOUNGE button for 5s, timer LED of remote flashes, the control box records current position as LOUNGE position;
When in the process of moving to memory positions, the head and foot actuators move first, then the tilt and lumbar actuators move; -
Lumbar actuator
Press and hold LUMBAR UP button of remote, lumbar actuator moves out, stop when released; -
Child lock button
In unlocked state, press and hold the child lock button, the red backlight of children lock button begins to flash, after 5s, the red backlight stops flashing, remote entersl into locked state;
Under the locked state, press any button except child lock button, the red backlight of child lock turns on, the button you pressed is invalid;
Under locked state, press and hold child lock button, red backlight of children lock begins to flash,after 5s, the red backlight stops flashing, remote enters into the normal working condition; -
moving in of lumbar actuator
Press and hold LUMBAR UP buton of remote, lumbar actuator moves out, stop when released;
Reset all memory positions to default settings
Pressa and hold ZG+FLAT buttons for 5s, timer LED of remote flashes, the control box reset all memory positions to default settings; Head up
Press and hold HEAD UP button of remote, head actuator moves out, stop when released; -
Head down
Press and hold HEAD DOWN button of remote, head actuator moves in, stop when released; -
Foot up
Pressa and hold FOOT UP button of remote, foot actuator moves out, stop when released; -
foot down
Press and hold FOOT DOWN button of remote, foot actuator moves in , stop when released; When moving to flat position, lumbar actuator and tilt actuator move first, after 500ms, head and foot actuators start moving; -
moving out of tilt actuator
Press anfd hold TILT UP button, tilt actuator moves out, stio when released; -
moving in of tilt actuator
Press and hold TILT DOWN button,, tilt actuator moves in, stop when released; -
Flat
Click FLAT button, the bed goes flat, stop when click any button during the process of going flat; -
Massage head
Click MASSAGE HEAD button, head massage motor switches massage intensity, massage intensityswitches among 0-1-2-3; -
Massage timer
If the massage motors do not work, the button is invalid, if the massage motors work, click the button to switch the massage time, when massage time switch to 0, turn off the massage;
Massage ON/LAST
Click the Massage ON / LAST button, if the massage motors are on, turn off the massage motors and record the current massage intensity and mode of head and foot massage motors. If the massage motor is off, turn on the massage motors and restore to the previous recorded massage intensity and massage mode (Note: Only when press the ON / LAST button only to turn off the massage motor, it will record the current massage intensity and massage mode, press the head and foot massage motor button or timer button or open the massage motor, it will not not record the status of massage motors); -
Massage ON/OFF
Click Massage ON/OFF button, if the massage motors are on, then it turns off massage motors,if massage motors are off, then it turns on the massage motors; -
Under bed light
Click the under bed light button, the under bed light switch its on/off state; After the under bed light opens, if do not manually close, it will automatically turn off after 5 minutes; -
Massage Type
Click massage type button, to switch the massage mode og massage motors, massage mode switches among type0type1type2type3type0; this button can only switch the massage mode, it can not open massage motors;
FCC
Please take attention that changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
ISED RSS Warning:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- this device may not cause interference,
- this device must accept any interference, including interference that may cause undesired operation of the device.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>