OKIN REFINED MC242 Control Box User Manual
- June 5, 2024
- OKIN REFINED
Table of Contents
OKIN REFINED MC242 Control Box
Electrical configuration diagram
Function Picture
- Process of test
- HEAD MOTOR
* Connect to head actuator, controlled by a remote single
* Click the head-up button on the remote, head actuator moves out, stops when released:
* Click head down button, head actuator moves in, stops when released:
* This function takes effect only by pressing the corresponding button on the remote.
2. **FOOT MOTOR**
* Connect to foot actuator,.control by remote single:
* Click foot up button, foot actuator moves out. stop when released:
* Click foot down button, foot actuator moves in, stop when released;
* This function takes effect only by pressing the corresponding button on the remote.
3. **TILT and Lumbar MOTOR**
* Connect to TILT and Lumbar actuator, control by remote single:
* Click bed up button, TILT and Lumbar actuator moves out, stop when released;
* Click bed down button, TILT and Lumbar actuator moves in, stop when released:
* This function takes effect only by pressing the corresponding button on the remote.
4. **Massage**
* Connect to Foot and Head vibrator,.control by remote single
* Click the ALL Massage button, Foot and Head vibrator work,and click again, the strength enhance,there is 3 degree all.
5. **SYNC port**
* Connect with the same other Control box or Other accessories;
6. **Power LED & PAIRING LED**
* Power supply for control box, PAIRING LED of the control box is blue, POWER LED is green.
7. **Power**
Connect to the 29V DC;
8. **RESET button**
Press and hold the RESET button, the Head, Foot actuators will move to lower position.
9. **Pair Function**
* Once the power on pairing LED turns on, the control box enters into the mode of code paring:
* Press and hold the pairing LED of the Remote, the backlight of the paring LED flashes, the backlight of the remote flashes, the remote enters into mode of code paring;
* The backlight of paring LED of remote stops flashing, and the paring led of control box turns off, it indicates that the code paring is successful;
* If fails, repeat all the processes above;
10. **FLAT function**
* Press and release the FLAT button on the remote, the head and foot actuators move to lower position(when the actuator is free, can turn oft the vibration motor and turn off the indicator light when pressed once), and stop when pressing any button;
* This function takes effect only by pressing the corresponding button on the remote.
11. **ZEROG position function**
* Press and release ZERO-G button on the remote, the head and foot actuator moves to preset memory position, stop when press any button
* This function takes effect only by pressing the corresponding button on the remote.
FCC:
Any Changes or modifications not expressly a pproved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC R ules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC RF Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
ISED RSS Warning
This device complies with Innovation, Science and Economic Development Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment.The device has been evaluated to meet general RF
exposure requirements.