ORION G Series 51452 StarShoot CMOS Cameras Instruction Manual

June 6, 2024
Orion

orion logo

ORION G Series 51452 StarShoot CMOS Cameras

ORION G Series 51452 StarShoot CMOS Cameras

Corporate Offices: 89 Hangar Way, Watsonville CA 95076 – USA Toll Free USA & Canada: 800-447-1001
International: +1(831) 763-7000
Customer Support: support@telescope.com

Copyright © 2021 Orion Telescopes & Binoculars. All Rights Reserved. No part of this product instruction or any of its contents may be reproduced, copied, modified or adapted, without the prior written consent of Orion Telescopes & Binoculars.

Welcome to the exciting world of astro-imaging. Your new StarShoot™ CMOS Imaging Camera is capable of capturing professional-quality astro-images of your favorite celestial objects. You can showcase spectacular images on your computer, share them on the internet, or print them. The camera’s large pixel array provides very high-resolution images which are great for publishing in large prints. Please read this instruction manual before attempting to use the camera or install the needed software. This manual covers installation of your camera along with basic functions of acquiring images using the included software. To get the most out of your camera using 3rd party dedicated astronomy apps coupled with the universal ASCOM driver for the G Series Camera, please consult the software help files and manuals included with the individual software packages available on the market. Some of our favorite programs are mentioned below. Note: This manual covers the StarShoot Mini cameras as well as the larger format cooled G series cameras. Some features will only be available on specific models.

The StarShoot CMOS Camera (G10 and larger) The StarShoot Camera is a high- resolution CMOS imager with a dual-stage, regulated thermoelectric cooler to enable maxi-mum imaging performance. It is very sensitive and capable of detecting faint deep sky objects in a short exposure; and longer exposures or higher gain settings can reveal extremely deep fields with subtle nebulosity and galaxies in the background. The unique versatility of CMOS chip lets you take advantage of the densely-packed pixel array. 1×1 mode utilizes the full resolution of the camera, providing the most detailed images and largest possible prints. The one-shot-color versions offer the easiest path to a full- color image, with the Bayer matrix over the chip to encode the color data without having to shoot through individual filters. The Monochrome versions are the most sensitive StarShoot cameras, because of the monochromatic nature of the chip, but will need to shoot through different color filters in order to produce a full-color image. Binning in 2×2 mode or higher shortens the exposures necessary and full well capacity of each pixel at the expense of resolution. Binning in 2×2 mode can be especially useful for longer focal length and higher focal ratio telescopes as well offers super-fast downloads when focusing with a Bahtinov mask or V-curve assisted motorized focuser.

Feature Highlights

  • Simple interface: A USB 3.0 port and power port are all that are needed to power and connect to the Camera (Figure 1).
  • Dual-stage thermoelectric cooler: Dramatically reduces thermal noise in all images, down to approximately 35 degrees C from ambient temperature.ORION G Series 51452 StarShoot CMOS Cameras-2
  • Regulated cooling: Enables you to set the exact temperature within the cooling range of the camera. This allows you to take calibration images like dark frames at the exact same temperature as your light frames, making for the cleanest images possible. Additionally, since you can match the CMOS temperature at any time (within the range of the cooler), you have the freedom to take dark frames when it’s most convenient for you, so you don’t have to use up valuable imaging time to take dark frames.
  • High speed USB 3.0 interface and internal memory buffer: The 512-megabyte onboard memory buffer ensures a clean image download each time, even if the system resources of your PC are temporarily compromised.
  • Two-port USB 2.0 hub (Figure 1): means cable management is much easier. Plug up to two other USB devices (such as an autoguider and electronic filter wheel into the camera, and only have the USB 3.0 cable and power cable coming off the telescope.
  • Status indicator lights (Figure 1): Shows connection to the camera, data transfers (flashing light), power to the electronics, TEC (thermoelectric cooler) and fan.

The StarShoot Mini CMOS camera
The StarShoot Mini cameras (6.3mp Color and Monochrome) are lower-cost alternatives to the larger G10 and above cam-eras. They are not cooled which means that while the inherent noise will be a bit higher, the size, cost, and power requirements are considerably reduced. The StarShoot Mini cameras are based around the Sony IMX 178 CMOS chip and excel at planetary imaging because of the super-fast frame rates and the tiny 2.4-micron pixels. In addition, they are capable of deep-sky imaging with exposures up to 1000 seconds. They also feature a standard SBIG auto guider port, so they can be used as a very sensitive autoguider while imaging through a different camera. For the most sensitive guiding, the mono version is recommended. All subsequent sections of this manual (including the deep-sky imaging section) pertain to the StarShoot Mini cameras as well, but some features such as the TEC cooler and AC power requirements, do not apply. The Mini cameras are powered fully by the USB 3.0 port on your computer.

Getting Started

Parts List
  • StarShoot G Series camera
  • 1.25” nosepiece (Mini), 2” nosepiece (G10 and above)
  • USB 3.0 cable
  • SBIG guide cable (Mini only)
  • DC power adapter and cable (G10 and above, and different AC plugs provided in EU/UK versions)
  • Hard carrying case (G10 and above)
  • Various adapter/spacers (G24 only)

Telescope
The StarShoot can be used with most telescopes on the market. The Mini cams slip into a 1.25” focuser, and the larger format cameras into a 2” focuser (Figure 3a).

The cameras are also compatible with any focuser that includes male 42mm T-threads (G10 and above) or male c-mount threads (StarShoot Mini). Caution: Be sure to always firmly tighten the thumbscrew(s) that secure the camera in the telescope focuser, or it could fall out and onto the ground! If your telescope has T or C threads for direct camera attachment, a more secure connection can be made. First, unthread the 1.25” or 2” nosepiece from the camera body to expose the C or T threads on the camera front housing. Then simply thread the camera onto your tele-scope (Figure 3b).

Back-focus Requirement (G10 and above)
The camera requires 17.5mm (0.689″) of back-focus. This is the distance from the front threads to the CMOS sensor. This is necessary info to have when calculating spacers to put behind a Coma Corrector or Field Flattener, which usually requires 55mm of space for optimum performance. Because of the necessity of a coma corrector or field flattener with the G24 Full Format on many style telescopes, the G24 includes some adapter and spacer rings to reach the optimal 55mm spacing. Other adapters in various sizes might be required depending on your specific attachments. Step-down adapters from 54mm, 48mm, or 42mm with 0.75mm thread pitch are widely available from many online retailers. We have found Blue Fireball brand adapter rings come in a wide selection of sizes, and might be of help to fit your specific need(s).

Mount
Deep-sky imaging with the G Series usually requires an equatorial mount with a right ascension (R.A.) motor drive. The goal for your mount is to seamlessly track the apparent movement of the sky as the Earth rotates. The tracking must be very accurate, or the object you want to image will drift and blur across the camera’s field of view while the exposure is taken. Even a small amount of drift will cause a star to look oblong instead of round. We recommend using a high-quality equatorial mount that utilizes periodic error correction (PEC) or has the ability to interface with an autoguider.

Computer
The camera requires a Windows PC to operate the camera. For astro-imaging in the field at night, a laptop computer is highly recommended. The included software requires Windows 7, 8, 10, and for full data speed, a USB 3.0 port is required. A large hard drive is also recommended, as the individual image files are quite large, and can take up a lot of disk space.

Power (G10 and above only)
The camera requires 12 volts DC (12VDC) to run the TE cooler. Power to the cooler and fan is supplied by the included 3amp AC/DC transformer when plugged into an AC outlet. Imaging in the field away from AC power usually requires the use of a por-table field battery to supply power. Make sure the power supply provides at least 3 amps of current for the duration of your imag-ing session. This allows the camera’s TEC to use 100% of its potential cooling power. The 12v input port accepts a standard 5.5mm/2.1mm DC TIP POSITIVE plug.

Software and Driver Installation
The software and driver must first be downloaded from the Orion website before plugging in the camera. Please go to: www.tele-scope.com/Gseries to download all the relevant software for your camera. Downloadable files include:

  • StarShoot Image Capture: camera control program
  • G series direct driver: for DirectShow applications
  • G series ASCOM driver: for camera control in 3rd part astro-imaging software.

Note it is HIGHLY recommended to install the ASCOM platform and download the G series ASCOM driver to use with the camera. Dedicated 3rd party camera control programs are available online which will unlock the full astro-imaging potential of the camera. To install the ASCOM platform, visit www.ascom-stan- dards.org and click the download button. Don’t forget to also install the G series ASCOM driver from Orion’s website AFTER you install the main ASCOM platform. When connecting to the camera in a 3rd party program using ASCOM, choose “ASCOM camera” from the camera selection menu, and then the G series camera should appear in the ASCOM camera selection window if the driver is properly installed.

  1. Download all relevant files from the Camera download page
  2. Double-click on the install .exe for the Image Capture program, the driver, and the ASCOM driver, and follow the onscreen directions for installation. Do not plug the camera in until the drivers have been installed for the camera.
  3. Once the driver and software has been installed, plug the camera into an available USB 3.0 port, and connect the AC power cord to the DC input on the camera (Figure 1), and connect to AC power (G10 and above only).
  4. Windows will take a moment to recognize the USB device plugged in, and once that is complete, you can open up the StarShoot Image Capture program to connect to the Camera.

Hardware setup
Now that the camera drivers and software are installed, it’s time to connect the camera to the telescope, and open up the soft-ware. Install the camera into your focuser, and for the G10 and above: connect any peripheral devices to the two USB 2.0 ports on the camera, and connect the camera to power. Please note the AC/DC transformer has a relatively short DC cable length. This prevents 12v voltage from dropping over longer runs, but you may find it difficult to reach an AC outlet depending on your scope setup. Use of an extension cord on the AC side of the adapter is suggested, and the DC transformer itself can rest on the tripod accessory tray, or secured with Velcro or some other method directly to the tube wall or telescope rings. If you need to extend the 12v side of the power cable, a 5.5mm/2.1mm DC extension cable (available from your local electronic supply) can be used, but please try to keep the length of the cable as short as possible. Finally, for all cameras including the Mini, connect the USB 3.0 cable from the camera to an available USB 3.0 port on the computer.
Focusing the camera for the first time can be tricky, since the camera may focus at a completely different place from where an eyepiece focuses. It is recommended that you first center a bright star in a 25mm eyepiece before attaching the camera, to be sure the camera is centered on the star. Even very far out of focus, you should be able to see a fat disk (the out-of-focus star), to determine which way to turn the focus knob to bring the star down to a focused point.

Software

The next section with document connecting to the camera and basic image downloads. The included software will run the basic astro-imaging steps including image download, cooler control, exposure controls and such, but please note that this software only touches on the basic functions of acquiring astro images. To get the best results with more advanced processes such as stacking multiple long exposures together to reduce noise, manual dark frame subtractions, flat field and dark frame stack-ing for smoother calibration frames, and other processes, it is HIGHLY recommended to control the camera with an ASCOM compatible capture program. Some are free on the web, others are paid, but there is a vast array of programs available that will be compatible with the camera. Here are some of our favorites:
DeepSkyStacker: http://deepskystacker.free.fr/ – Excellent free program for pre-processing that simplifies the alignment and stacking of your images. Automatically monitors a directory where images are saved, and processes on the fly. Add all the calibration frames, including darks, flats, biases, and step back while the software does the rest giving you output ready for post- processing in programs such as PhotoShop.
RegiStax: www.astronomie.be/register/ – Excellent free pro-gram for aligning, stacking and processing of AVI video files, ideal for capturing lunar and planetary video, splitting the video into individual frames, analyzing each frame and aligning/stack-ing/processing the best ones for pulling out fine details.
SharpCap: sharpcap.co.uk–Free camera control and capture program. Features include video and long exposure control, flat

ORION G Series 51452 StarShoot CMOS Cameras-6

field and dark frame subtractions, histogram control, excellent focus assist routines including Bahtinov mask overlays and FWHM measurements, and MUCH more!
Sequence Generator Pro: mainsequencesoftware.com – free 45-day trial. Excellent Image Capture suite to control all aspects of your setup. Create sequences of exposures of different lengths, control a Go-To mount for automatic pointing and auto-centering in any part of the image, auto v-curve focusing with a compatible electronic focuser (without having to re-center to a target star), autoguider control, and a host of other features.
Nebulosity: stark-labs.com – free demo available to try. Powerful, yet very easy to use image capture and processing program. Excellent processing routines such as aligning/stacking and dark/flat/bias handling. An excellent choice for the beginning astro-photogra-pher getting into processing, yet will carry over for more advanced users as well.
Orion StarShoot Image Capture

ORION G Series 51452 StarShoot CMOS Cameras-8

Plug the camera into the USB 3 port, and into AC power. When you open Orion Starshoot Image Capture, you’ll be presented with the main preview win-dow on the right, and the control options on the left-hand side. (Figure 4). On the top of the left-hand side, click the camera name to start a video preview (Figure 4a). Scrolling down the left-hand side, you’ll find all the controls for operating the camera. The primary window to control the exposure and to use first is the Capture and Figure 5. The Capture and Resolution window (Figure Resolution windowpane
5). In this window, you can
set either video or still image mode (trigger mode), as well as set the resolution and gain of the camera and set single, loop-ing, or sequence shots to be saved automatically in a chosen directory.
Scrolling down further along the left side, you’ll find windows for other camera attributes including bit depth (always choose the highest bit depth to get the most detail and quality out of the image), binning control (1×1 is full camera resolution), histogram, and cooler control. There are other windows pres-ent, but the ones listed above are the most important ones when taking your first image. Some windows are not appli-cable to astro-imaging, and can be shut off by going into the Options>preferences menu.
To take your first image, focus must be achieved. With a CMOS camera, one of the quickest and easiest ways to focus is to point the camera at a bright star, and choose a fast video frame rate with higher gain settings so you can watch the star in real time, and focus until the star becomes a point.
Focusing

  1. Make sure the camera is in preview mode – if not, click the camera name in the top left window, to turn on streaming preview mode.
  2. In the Capture and Resolution window (Figure 5), set the resolution to full, the gain to somewhere in the middle of the slider, and the exposure to video mode with “auto exposure” unchecked, and an exposure time to somewhere around 200-500 milliseconds. This should provide you with several frames per second, enough to see a real-time focus preview.
  3. This should be good enough to see a bright star-like Vega, provided it’s in the field of view, and relatively close to focus. If you see nothing, but are sure the star is in the center of the field, adjust your focus in and out because a very out-of-focus star will spread out and become quite dim.
  4. Once you acquire the star, center it, and focus until it looks like a tiny point. At this point you are probably over-exposing the star, and can back off on the exposure time and gain settings. If the star is in the middle of the field, you can also reduce the resolution setting on the chip, in order to speed up the frame rate, to get a super-responsive live focus. Readjust focus until the star is as tiny as possible. At this point, everything including the moon and a distant galaxy will be in focus.
  5. If you wish to fine tune the focus further, a Bahtinov mask is an ideal method of focusing with Orion StarShoot Capture, as it is quite an accurate method using medium brightness stars. Contact Orion or search for Bahtinov mask on www.telescope.com for more details, and to purchase a Bahtinov mask for your specific telescope.

Your First Lunar/Planetary Image
The moon is perhaps the easiest object to get your first image, as it is very bright, and easy to find. Planets are also easier than nebulae to capture, since you’ll be streaming a video file, and can use programs such as Registax to process the video file.

  1. Go to the Options menu, click preferences, and under the Record heading, choose a directory location for your saved files, naming convention of your choice, and make sure the file type is set to AVI.
  2. In the Capture and Resolution window pane, check Video Mode, uncheck auto exposure, and use the Exposure Time slider to find an exposure that looks good. Planets do well with lots of short exposures, so if the exposure time is too long, experiment with raising the gain, and lowering the exposure value. It will be more noisy, but the frame rate will be higher, and the exposure time will be lower.
  3. When ready to record, press the record button and press it again when your video is the desired length. In the Options menu, under Record preferences, you can set limits to time of the video, as well as number of frames.
  4. You can then load your AVI file into a 3rd party program such as RegiStax, in order to process the lunar or planetary details present in the video file.

Auto Exposure can be used if desired, but manually adjusting the exposure values provides the best control over the image. Check the “Auto Exposure box, and drag the box over an area you wish the system to measure. You can resize the box accordingly. Then set the Exposure Target, and the system will try to keep the exposure close to that target exposure value by adjusting the exposure time automatically.

Your First Deep Sky Image

  1. Now that you’re focused, slew to an object you wish to take a picture of, and the exposure and gain settings will
    ORION G Series 51452 StarShoot CMOS Cameras-9ORION G Series 51452 StarShoot CMOS
Cameras-10need to be adjusted for best the best possible result. For longer nebulae exposures, trigger mode is recommended.

  2. For a nebula or star cluster, choose something bright
    for your first target, and ideally an autoguider is already locked on and tracking a star, so your resulting images are well guided. Pick an object like the Ring Nebula (M57), Dumbbell (M27), or Orion Nebula (M42) since they are all very bright and easy to see in short exposures to make sure the framing is correct. Center the object and proceed to set the exposure.

  3. Set the analog gain slider to around 25% from the left
    (around 40), and a trigger mode exposure of 30 seconds, and make sure the bit depth is set to the highest bit depth possible. This is just a starting point, these numbers may have to be adjusted depending on your resulting image.

  4. Click Single and wait for the image to download. You should see a rather grainy looking image of your target in the preview window on the right. Now is the time to look at the histogram window, and determine what needs to change in order to get the best exposure. Scroll down the left side panel to find the histogram window.

  5. The histogram shows a graphical representation of the number and brightness of the pixels in the image. The far left of the histogram is black, or no light on a given pixel, and the far right is full white, or fully maxed brightness for those pixels. A normal astrophoto has a lot of black in it, so the histogram bump should be left of center (approximately near the left 1/4 to 1/3 of the histogram for the hump) for a properly exposed photo of a nebulae with a lot of black sky around it (Figure 6a). If the hump is too far to the right, either the exposure or the gain is set too high, and you’re recording too much background light pollution.

  6. Adjust the exposure to somewhere between 30 seconds and 180 seconds. For a CMOS chip like the G Series, individual exposures probably do not need to be longer than 180 seconds, especially when you’ll be stacking many shots together for the best results. The G16 color and G21 color camera are not quite as sensitive as the G10 color, so exposures longer than 180 seconds may be possible and advantageous to gather more light.
    The G16 mono is the most sensitive of all — but since
    it is a monochromatic camera, in order to obtain a full-color image you’ll need to shoot through red, green, and blue filters, and process the resulting frames together to produce a color image. If the histogram still doesn’t fall into the proper area, the gain can also be adjusted. Higher gain setting means more noise in the image, but it will provide more sensitivity for a given exposure. Finding the right exposure vs. gain combination is a matter of trial and error, and will vary depending on the telescope focal ratio and sky conditions.

  7. If you want to “screen stretch” the histogram, meaning change the black and white points in the image in order to see what kind of faint detail you have captured, grab the left and right edges of the histogram window, and slide the vertical bars closer to the histogram bump. Moving the right edge bar closer to the end of the hump will raise the brightness of the entire image, and moving the left edge bar closer to the start of the hump will darken down the black point, boosting the contrast. (Figure 6b). Note that the live histogram stretching will NOT change a trigger image that is displayed on the right. It will affect the NEXT image that downloads from the camera, so take another exposure and check the results.

  8. Once you’ve dialed in the right histogram, it’s time to start a sequence so you can stack several images together. Remember that each individual image will have lots of noise, and only by stacking many images together will you get a smooth low noise image.

  9. In the Capture and Resolution window, click “Options”
    in the lower right corner of the window and choose a
    file location to save your resulting images. Make sure to save them as .fit files so 3rd party astro-imaging software can read them (.fit is a standard in the astro-imaging community). Verify that the resolution you wish to image at is set, and also make sure RAW is set for the file type. RAW fits files are saved before color converting so other programs can read the raw files and provide the best data from the camera. Also, make sure “Light Frame” is selected in the window across the top, so the correct meta-data is ORION G
Series 51452 StarShoot CMOS Cameras-11ORION G Series 51452 StarShoot CMOS
Cameras-12
    saved in the .fit file header. Many programs look to the fits header to determine the type of file (Light, Dark, Flat…), so they can be automatically processed correctly without the user specifying the type of image.

  10. Once everything is set and your autoguider is up and running locked on and tracking a star, choose a number of shots in the sequence, then click sequence and sit back and let the camera collect the images. Later, when processing, if you find your stacked images too noisy, you’ll want to stack a larger number of shots together to reduce the noise.

  11. When those exposures are finished, you might also want to collect some dark frames, so you can subtract them from the light frames in your 3rd party astro-imaging software. Choose “dark frame” instead of “light frame,” and take at least one dark frame with the cap on the telescope that you will later subtract from the light frames in your other software. Darks should be taken at the same exposure, temperature, and gain setting as the lights
    you previously took. See below for more discussion on calibration frames such as darks and flats.

Congratulations, you’ve just taken your first series of deep-sky images with your new camera! It’s now time to do some pro-cessing in some of those other suggested programs such as DeepSkyStacker or Nebulosity in order to get the cleanest final image possible. It’s not uncommon to shoot dozens of light images, especially when imaging something faint that hides in the background noise. The greater the number of images, the more you can push the processing and pull out the detail. Even dark frames can benefit from averaging many together. A mas-ter dark or flat made of many individual frames has significantly less noise than only one.
Also, make sure to adjust the histogram to show some of the faint detail that may not be visible upon first downloading an image. Previously, the “Live Histogram” adjustment was shown, but there’s another way to adjust the histogram of a saved image. Figure 7a and 7b show a downloaded 120 second

ORION G Series 51452 StarShoot CMOS Cameras-13

image of the Veil Nebula. Figure 7a shows the full range (select Menu>Process>Range to bring up a histogram of that image). Notice how faint the nebulae looks? That’s not uncommon for a nebula to look like this right out of the camera, as it is just barely brighter than the background light pollution. Figure 7b is a Range adjusted shot, to show fainter detail. Notice how the left and right range lines are set just outside each end of the histogram? The background is brighter but ready for more processing in Photoshop to reset the black point and clean the image up. Figure 8 is a finished image, with dark frames subtracted and a stack of thirty 120 second light frames, 9 dark frames, processed in DeepSkyStacker and Photoshop.

Imaging with a Mono camera
One-shot color cameras are relatively easy to get a final image from because there is less processing involved. But color chip cameras suffer from less sensitivity to light than a monochrome camera does. The reason is due to the Bayer Matrix over the chip. The pixels are arranged in squares of alternating colors (for example RGGB in the G10). This means that for every four pixels in a square, only one of them is sensitive to red light, and only one to blue. But in a monochrome chip, every pixel sees ALL of the photons of light across the visible spectrum. The result is a much more sensitive chip. This is much more versatile, because you can put any kind of filter in front of the camera, depending on the wavelength of light you want to capture. And not just Red, Green and Blue — consider narrow-band imaging with Hydrogen-Alpha, Oxygen-III, and Suphur II filters as your RGB channels. This can dramatically boost the contrast on nebulae, and also allow imaging even in more severe light pollution than otherwise would be possible. Also consider a motorized filter wheel such as the Orion StarShoot 2” Motorized USB Filter Wheel to automate the process of switching filters between exposures.

Cooling – for less noise

The TEC in your G10 and above is designed to reach temperatures of up to 35 degrees below the ambient temperature. As the chip gets colder, noise becomes less pronounced, so the ORION G Series 51452 StarShoot CMOS
Cameras-14

ORION G Series 51452 StarShoot CMOS Cameras-16resulting image is cleaner. In StarShoot Image Capture, you can find the current temperature of the chip in the lower right-hand corner of the screen, next to the current resolution (Figure 9a). Cooler control is located down the list in the left-hand window pane (Figure 9b). Note the current temperature of the camera, then turn the cooler on, set a target temperature, and wait for the chip to reach that target temp. Please note that the colder the chip, the more prone to internal dew. The CMOS chamber has been purged of moisture at the factory, but pushing the cooler to its limit may still cause whatever moisture remains to condense on the chip. You’ll notice this in the image as a circular pattern that grows in the image, and a major loss of detail.
If the chip dews over, raise the target temperature and give the chip a few minutes to acclimatize. Raising the temp to 0 degrees C should remove any dew after a few minutes. It’s good to reduce the temperature of the chip, but it doesn’t have to be all the way down to 35 degrees below ambient. Somewhere between 15-25 degrees below ambient still provides a great noise reduction, but with much less chance of the chip dewing over. Once the target temp is reached and is stable, proceed with taking your light and dark frames. They must both be at the same exposure length and temperature for the darks to correctly calibrate. Since the cooler is regulated, you can also use these darks in subsequent imaging sessions, as long as you keep the target temperature the same night tonight for your light frames. This is another good reason not to reduce the temperature to its lowest possible setting. If the next night is warmer, it won’t be possible to drop the cooler as far from ambient temperature.

Conversion Gain

Along the left-hand pane is a window for conversion gain, and options (if your specific camera supports both options) for LCG and HCG — low and high gain. LCG should be used most of the time, especially when a lower gain setting is used. However,if you are boosting the gain up high to keep exposures times lower, try switching to HCG and readjusting gain, which can reduce read noise in the chip without losing as much dynamic range in the image. But when in doubt, stay in LCG mode, and your images will turn out fine. The ASCOM driver also includes LCG/HCG settings when in 3rd party control programs.

Dark Frames
Dark frames are images taken with no light coming into the camera. A dark frame is typically taken with the telescope cap attached. The only data in the image is the inherent camera noise. The noise contains the dark current (background noise level), read noise (noise introduced during camera readout and download) hot pixels (bright dots in the image) and amp glow (Figure 10). All of this noise exists in your raw astro-image too, which distracts from the detail you want to see. To eliminate most of the camera noise, you can take several dark frames, average them together, then subtract this “master dark” from your “light” astro-images. Note: Make sure the cooler setpoint and camera temperature are the same as they were when you took your light frames. Dark frames are handled through most of the 3rd party control programs listed previously.

Flat Field Frames
Flat Frames are more advanced and mentioned here as a point of reference. A flat field is an image taken with uniform feature-less light entering the telescope, such as a blue sky in the early morning or after sunset. Flat fields solve a number of issues in your astroimages:
Vignetting
Vignetting in a telescope reveals edge-darkening in the Astro-image. Vignetting is more apparent when the telescope’s illuminated field is not large enough to illuminate the full area of the chip. As a result, more light is detected in the center of the image compared to the edge.
Dust and Particles
Dust and particles will inevitably show up in your raw Astro-images. Large particles on the camera optical window sometimes look like unfocused circles or doughnuts in your images. It’s too late to clean your camera if you are already imagining in the field at night. And even when the camera is clean, dust usually finds a way to show up in your images.

Telescope Artifacts
Very large particles or other artifacts in your telescope can affect your astro-images. Insufficient telescope baffling or poor collimation can also cause unsymmetrical field illumination in your images.

To take a flat field image

  1. Ensure that the telescope is focused and ready for astro-imaging.
  2. Point the telescope at a uniform and featureless light source, like the sky at dusk or dawn, or a blank white sheet of paper. Make sure the camera orientation is exactly the same as it is or was for astro-imaging (Although the telescope is pointing at a featureless surface, the focus and orientation must be set as it normally would be for astro-images.)
  3. Set the Frame Type in your imaging control program to Flat Field for correct metadata flagging in the fits header.
  4. Set the exposure to result in a histogram which has a hump at around 1/3 to 1/2 of full exposure.
    Import your Darks and Flats into the programs mentioned above for full image calibration of your astrophotos.

Image Processing

It’s not uncommon to use 3-4 programs to tweak the astro-images you’ve taken to get the best possible final result. Please delve into the manuals for the other programs listed above, along with output for Photoshop, Lightroom, or other standard image processing programs. The images taken for this manual and on telescope.com were all taken using a combination of StarShoot Image Capture, SharpCap, DeepSkyStacker, and PhotoShop.

Color Conversion (one-shot color cameras only)
It was mentioned previously to save the images in the RAW .fit format, for later processing in 3rd party software. RAW is a “black and white” format with a “screen door effect” laid over the image. This screen door is the Bayer Matrix, and contains the color data. When you convert the RAW format to a color format, the screen effect disappears and you’re left with a full-color image. The preview window in StarShoot Image Capture shows a color image, but if you set the saved file type to RAW, you will save an unconverted black and white image in the .fit format.
To convert to color, see the instructions included with the 3rd party software packages, but you’ll have to also determine the X and Y offset, in order to reproduce correct colors. This is different in each software program and usually requires experiment-ing in order to correctly convert. Color balance may also have to be adjusted to correctly display the image from a chip that is most sensitive in Green, and less sensitive in blue. For example, in DeepSkyStacker, we found the best setting was “generic RGGB” for the Bayer matrix filter, and “Bi-linear Interpolation”. After that, color balance could be used to rebalance the background levels to a neutral color.
NOTE: the G16 Color Bayer Matrix is arranged GRBG or BGGR (depending on the software you are using), instead of RGGB in the others. X and Y offsets are different.

ASCOM Driver

The ASCOM driver allows the camera to be used with any of the programs listed above, along with any others that support ASCOM cameras. Please download the ASCOM platform from Ascom-standards.org and make sure to install the camera ASCOM driver from Orion’s website. When in 3rd party camera control programs, the camera gain settings can be controlled in the ASCOM setting window for the camera. Open the ASCOM camera settings, adjust the gain, and experiment with exposures as detailed above. Since stacking reduces noise, it can be beneficial to have a bit more noise in the image, if it helps keep the exposure times down. One last thing to note, some programs may use a percentage for gain, others may use the actual gain numbers. If the gain range is 0-100, it’s using a percentage of total gain.

G24 Spacing rings
Since the G24 is a full format camera chip, it becomes necessary to use a coma corrector on most Newtonian reflectors, or a field flattener on refractors in order to optimize the distortion correction of the telescopes field. Most coma correctors and field flatteners need to be positioned with 55mm distance between the chip and the attachment threads on the lens. This 55mm distance is the default spacing for a DSLR housing, but cameras such as the G24 have a chip mounted closer to the front opening (17.5mm in the case of the G24). Because of this, we are providing several spacer adapters that will replace the standard 2” nozzle on your G24 (figure 11). Thread in the 54mm – 48mm ring first (21mm length), then the 16.5mm extension ring, and then your coma corrector/field flattener (assuming it has 48mm t-threads. This will provide 55mm distance between the chip and the corrector/flattener.
If you have a coma corrector or flattener that uses 42mm threads, use the 48mm to 42mm zero profile ring to step the threads down to 42mm. We do not usually recommend this, as a 42mm opening will vignette the larger chip, and the edges of your field will become darker.
Please note that the standard 2” nozzle that is included with the G24 is threaded for Orion filters (M48 x 0.6mm), and does not use the camera t-thread pitch of 0.75mm. If you wish to add the extensions or purchase other length extensions online, make sure to be using the native opening of the camera (M54 x 0.75), or one of the spacing rings which also provides 0.75mm thread pitch in either the 48mm or 42mm diameter.

ORION G Series 51452 StarShoot CMOS Cameras-17

Specifications

  • Sensor:                        Sony IMX 294 color CMOS, 4/3 format
  • Resolution:                Up to 4128×2808
  • Pixel Size:                  4.63 microns
  • Diagonal size of chip: 23.1mm
  • Bayer Matrix pattern:    RGGB arrangement
  • Exposure range:      0.1ms – 1000s
  • Shutter:        Rolling Shutter
  • Partial frame download:    Region of interest and Sub-frame download supported
  • Binning:                  1×1, 2×2, 3×3, 4×4 hardware and software binning
  • ADC:                  14 bit
  • QE peak:                76%
  • Read Noise:      1.12e@HCG Mode
  • Full Well:      66.6ke
  • Image Buffer:    512MB memory buffer
  • Interface:    USB3.0/USB 2.0
  • Front nozzle threads:  42mm T-threads
  • CMOS chip window:  IR blocking, 380-690nm
  • Dimensions:            80mm x 103mm
  • Weight:          535g
  • Back Focus:  17.5mm
  • Cooling:            Regulated Two-Stage TEC,~35 deg C from ambient
  • Camera electronic power:  DC 5v from PC USB port
  • Cooler power:  12v/3a

One-Year Limited Warranty

This Orion product is warranted against defects in materials or workmanship for a period of one year from the date of purchase. This warranty is for the benefit of the original retail purchaser only. During this warranty period Orion Telescopes & Binoculars will repair or replace, at Orion’s option, any warranted instrument that proves to be defective, provided it is returned postage paid. Proof of purchase (such as a copy of the original receipt) is required. This warranty is only valid in the country of purchase.
This warranty does not apply if, in Orion’s judgment, the instrument has been abused, mishandled, or modified, nor does it apply to normal wear and tear. This warranty gives you specific legal rights. It is not intended to remove or restrict your other legal rights under applicable local consumer law; your state or national statutory consumer rights governing the sale of consumer goods remain fully applicable.
For further warranty information, please visit www.OrionTelescopes.com/warranty.