Orion V00 Vacuum Switches User Manual

May 15, 2024
Orion

Orion V00 Vacuum Switches

Specifications

  • Model: KU Vacuum Switches
  • Pressure Capsule Details:
    • Disc (Alu)
    • Pressure Housing (SS)
    • Plunger (SS)
    • Diaphragm (SS)
    • Junction Plate (AL)
  • Electrical Rating: 5A, 250VAC; 0.2A, 250 VDC
  • Pressure Port: 1/4 BSPF

Product Usage Instructions

Installation:

  1. Refer to the installation drawing provided in the manual.
  2. Ensure all wetted parts are securely connected as per the drawing.
  3. Mount the vacuum switch in a suitable location following the dimensions specified.

Range Selection:

  • Refer to the Range Selection Table to choose the appropriate range code based on your requirements.

How to Order:

  • To order MN/MA series vacuum switches, specify the full model number based on the provided groups and options.

FAQ

  • Q: How do I select the appropriate range for my vacuum switch?
    • A: Refer to the Range Selection Table in the manual and choose the range code that best fits your application requirements.
  • Q: What are the electrical ratings of the vacuum switches?
    • A: The electrical rating is 5A at 250VAC and 0.2A at 250VDC.

PRESSURE CAPSULE DETAILS

Orion-V00-Vacuum-Switches-fig-1..

No. / Description

  1. Disc (Alu)
  2. Pressure Housing (SS)
  3. Plunger (SS)
  4. Diaphragm (SS)
  5. Junction Plate (AL)

Note: wetted parts are mentioned in italics.

INSTALLATION DRAWING

Orion-V00-Vacuum-Switches-fig-2

VACUUM SWITCHES

GENERAL INFORMATION

KU series vacuum switches are housed in pressed steel powder coated enclosure and are recommended for panel mounting or indoor service. The KU series vacuum switch has a SS316 welded diaphragm. KU series vacuum switches have passed the Helium leak test i.e. they are completely leakproof which makes it possible to achieve a full vacuum. The repeat accuracy is better than ± 1.5% FSR. The Pressure port is 1/4” BSPF standard.

FEATURES

  • Compact
  • Separate chamber for working parts
  • Choice of wetted parts to suit working media
  • Electrical rating: 5A, 250VAC; 0.2A, 250 VDC
  • Pressure port: 1/4” BSPF

RANGE SELECTION TABLE

Range code| Range vacuum (falling) mm Hg (”Hg)| *Approximate Maximum Differential (Fixed) mm Hg (”Hg)| Maximum Working Pressure bar (psi)
---|---|---|---
V00| †        760 – 100

(29.92 – 3.94)

| 100

(3.94)

| 12

(171.43)

  • ***** Minimum differential increases with setpoint (Graphs available on request)
  • Typical values achieved at sea level, total vacuum that can be achieved varies mainly with altitude.

HOW TO ORDER

HOW TO ORDER MN / MA SERIES VACUUM SWITCHES

Group 1| Group 2| Group 3| Group 4| Group 5| Group 6
---|---|---|---|---|---
Model| Range Code| Range Scale| Disc| Diaphragm| Enclosure
KU –

Fixed differential Vacuum Switch

| V00 – High range vacuum Switch| –| –| –| –

Eg. A fixed differential vacuum switch, high range from 760 mm Hg vac. To 100 mm Hg vac. in calibrated style, with aluminium pressure housing, a Teflon diaphragm & a standard enclosure shall be specified by

Group 1| Group 2| Group 3| Group 4| Group 5| Group 6
---|---|---|---|---|---
KU| V00| –| –| –| –