Rheem Manufacturing Renaissance RACD Series Line Package Air Conditioner Instructions
- June 12, 2024
- Rheem Manufacturing
Table of Contents
Unit Features & Benefits
RACD Series
FACTORY INSTALLED OPTIONS:
- Louvered panels
- Hinged access doors
- PlusOne® HumidiDry® Dehumidification System (ZS/ZT)
- Low ambient/ freeze stat
- Non-powered convenience outlet
- Economizer (Title 24 and ASHRAE 90.1 2013 Compliant)
- Supply and return smoke detector
- Return smoke detector
- ElectroFin® E-Coat for Microchannel Condenser Coil
- ClearControl™ Direct Digital Control (DDC)
- Comfort Alert/Phase monitor
- Vertical economizer
FIELD INSTALLED ACCESSORY EQUIPMENT:
Accessory
| Model Number|
Factory Installation Available?
---|---|---
Economizer w/Single Enthalpy (Downflow)| RXRD-01MDDAM3|
Yes
Economizer w/Single Enthalpy (Horizontal)| RXRD-01MDHAM3|
No
Economizer-w/Single Enthalpy (Downflow) DDC| RXRD-01MDDBM3|
Yes
Economizer w/Single Enthalpy (Horizontal) DDC| RXRD-01MDHBM3|
No
Dual Enthalpy Kit| RXRX-BV01|
No
Dual Enthalpy Kit DDC| RXRX-BV02|
No
Carbon Dioxide Sensor (Wall Mount) | RXRX-AR02|
No
Power Exhaust| RXRX-CDF01C |
No
Power Exhaust| RXRX-CDF01D|
No
Manual Fresh Air Damper| RXRF-ADA1|
No
Motorized Fresh Air Damper | RXRF-ADB1 |
No
Motorized Fresh Air Damper (DDC)| RXRF-ADC1|
No
Roofcurb, 14″| RXKG-DDD14|
No
Roofcurb, 24″| RXKG-DDD24|
No
Roofcurb Adapter| RXRX-DDCAE|
No
Concentric Diffuser 7.5/8.5 Ton Flush| RXRN-AEF2000|
No
Concentric Diffuser 10.0 Ton Flush| RXRN-AEF3415|
No
Concentric Diffuser 12.5 Ton Flush| RXRN-AEF3618|
No
Concentric Diffuser 7.5/8.5 Ton Drop| RXRN-AED2000|
No
Concentric Diffuser 10.0 Ton Drop| RXRN-AED3415|
No
Concentric Diffuser 12.5 Ton Drop| RXRN-AED3618|
No
Concentric Adapter 7.5/8.5 Ton Drop| RXMC-DD01|
No
Concentric Adapter 10 Ton Drop| RXMC-DD02|
No
Concentric Adapter 12.5 Ton Drop| RXMC-DD03|
No
Outdoor Coil Louver Kit – ACD/090/102/120| RXRX-ADD04A|
Yes
Outdoor Coil Louver Kit – ACD150| RXRX-ADD04B|
Yes
Unwired Convenience Outlet| RXRX-BN01|
Yes
Unfused Service Disconnect| RXRX-BP01|
Yes
Comfort Alert (1 Per Compressor)| RXRX-AZ01 DDC|
Yes
Comfort Alert (1 Per Compressor)| RXRZ-AZ02|
Yes
BACnet Communication Card| RXRX-AY01|
No
LonWorks Communication Card| RXRX-AY02|
No
Room Humidity Sensor| RHC-ZNS4|
No
Room Temperature and Relative Humidity Sensor| RHC-ZNS5|
No
Low-Ambient Control Kit| RXRZ-A04|
Yes
Freeze Stat Kit| RXRX-AM01|
Yes
Variable Frequency Drive Kit*
*See model number break down below
| RXRX-AC02|
No
RXRX-AC03|
No
RXRX-AC05|
No
RXRX-AD02|
No
RXRX-AD03|
No
RXRX-AD05|
No
RXRX-CC02|
No
RXRX-CC03|
No
RXRX-CC05|
No
RXRX-CD02|
No
RXRX-CD03|
No
RXRX-CD05|
No
Electric Heater Kits| RXJJ-DD10CP|
Yes
RXJJ-DD15CP |
Yes
RXJJ-DD20CP|
Yes
RXJJ-DD30CP|
Yes
RXJJ-DD40CP |
Yes
RXJJ-DD10DNV|
Yes
RXJJ-DD15DNV|
Yes
RXJJ-DD20DNV|
Yes
RXJJ-DD30DNV|
Yes
RXJJ-DD40DNV|
Yes
Single Point Wiring Kit*| RXJX-AC0605|
No
RXJX-AC0805|
No
RXJX-AD0605|
No
RXJX-AC0909|
No
RXJX-AD0609|
No
See single point wiring kit model nomenclature on page 83.
Variable Frequency Drive Kit model nomenclature on page 83.
Accessory
| Model Number| Shipping Weight Lbs. [kg]| Installed Weight Lbs. [kg]|
Factory Installation Available?
---|---|---|---|---
Economizer w/Single Enthalpy (Downflow)| RXRD-01MDDAM3|
86 [39.0]
| 57 [25.9]|
Yes
Economizer w/Single Enthalpy (Horizontal)| RXRD-01MDHAM3|
84 [38.1]
| 55 [24.9] |
Yes
Economizer-w/Single Enthalpy (Downflow) DDC| RXRD-01MDDBM3|
86 [39.0]
| 57 [25.9] |
No
Economizer w/Single Enthalpy (Horizontal) DDC| RXRD-01MDHBM3|
84 [38.1]
| 55 [24.9] |
No
Dual Enthalpy Kit| RXRX-BV01|
1 [.5]
| 1 [.5]|
No
Dual Enthalpy Kit DDC| RXRX-BV02|
1 [.5]
| 1 [.5]|
No
Carbon Dioxide Sensor (Wall Mount)| RXRX-AR02|
3 [1.4]
| 2 [1.0] |
No
Power Exhaust| RXRX-CDF01C|
58 [26.3]
| 48 [21.8]|
No
Power Exhaust| RXRX-CDF01D |
50 [22.7]
| 44 [20.0] |
No
Manual Fresh Air Damper| RXRF-ADA1|
15 [6.8]
| 12 [5.4]|
No
Motorized Fresh Air Damper| RXRF-ADB1|
38 [17.2]
| 31 [14.06]|
No
Motorized Fresh Air Damper (DDC)| RXRF-ADC1 |
38 [17.2]
| 31 [14.06] |
No
Roofcurb, 14″| RXKG-DDD14|
109 [49.4]
| 104 [47.2] |
No
Roofcurb, 24′| RXKG-DDD24|
145 [65.8]
| 140 [63.5]|
No
Roofcurb Adapter| RXRX-DDCAE|
235 [106.6]
| 215 [97.5]|
No
Concentric Diffuser 7.5/8.5 Ton Flush| RXRN-AEF2000|
235 [106.6]
| 215 [97.5] |
No
Concentric Diffuser 10.0 Ton Flush| RXRN-AEF3415|
30 [13.6]
| 25 [11.3] |
No
Concentric Diffuser 12.5 Ton Flush| RXRN-AEF3618|
250 [113.4]
| 130 [59]|
No
Concentric Diffuser 7.5/8.5 Ton Drop| RXRN-AED2000|
275 [124.7]
| 170 [77.1] |
No
Concentric Diffuser 10.0 Ton Drop| RXRN-AED3415|
35 [15.9]
| 30 [13.6] |
No
Concentric Diffuser 12.5 Ton Drop| RXRN-AED3618|
270 [122.5]
| 160 [72.6] |
No
Concentric Adapter 7.5/8.5 Ton Drop| RXMC-DD01|
300 [136.1]
| 180 [81.6] |
No
Concentric Adapter 10 Ton Drop| RXMC-DD02|
25 [11.3]
| 20 [9.1] |
No
Concentric Adapter 12.5 Ton Drop| RXMC-DD03|
75 [34]
| 65 [29.5] |
No
Outdoor Coil Louver Kit – ACD/090/102/120| RXRX-ADD04A|
52 [23.6]
| 47 [21.3] |
Yes
Outdoor Coil Louver Kit – ACD150| RXRX-ADD04B|
43 [19.5]
| 39 [17.7] |
Yes
Unwired Convenience Outlet| RXRX-BN01|
2 [1.0]
| 1.5 [.7]|
Yes
Unfused Service Disconnect | RXRX-BP01|
10 [4.5]
| 9 [4.1] |
Yes
Comfort Alert (1 Per Compressor)| RXRX-AZ01 DDC|
3 [1.5]
| 2 [0.9] |
Yes
Comfort Alert (1 Per Compressor)| RXRX-AZ02|
3 [1.5]
| 2 [0.9] |
Yes
BACnet Communication Card| RXRX-AY01|
1 [0.5]
| 1 [0.5]|
No
LonWorks Communication Card| RXRX-AY02|
1 [0.5]
| 1 [0.5]|
No
Room Humidity Sensor| RHC-ZNS4|
1 [0.5]
| 1 [0.5]|
No
Room Temperature and Relative Humidity Sensor| RHC-ZNS5|
1 [0.5]
| 1 [0.5]|
No
Low-Ambient Control Kit| RXRZ-A04|
4 [1.8]
| 3 [1.4] |
Yes
Freeze Stat Kit| RXRX-AM01 |
2 [1.0]
| 1.5 [.7] |
Yes
[ ] Designates Metric Conversions
ROOFCURBS (Full Perimeter)
- Rheem’s roofcurb design can be utilized on all 7.5-12.5 ton [26.4-44.0 kW] RACD.
- Two available heights (14″ [356 mm] and 24″ [610 mm]) for ALL models.
- Quick assembly corners for simple and fast assembly.
- Opening provided in bottom pan to match the “Thru the Curb” electrical connection opening provided on the unit base pan.
- 1″ [25 mm] x 4″ [102 mm] Nailer provided.
- Insulating panels not required because of insulated outdoor base pan.
- Sealing gasket (40′ [12.2 m]) provided with Roofcurb.
- Packaged for easy field assembly.
Roofcurb Model
| Height of Curb
---|---
RXKG-DDD14|
14″ [356 mm]
RXKG-DDD24
|
24″ [610 mm]
- INSULATION*
- *DUCT
- NAILER STRIP
- GASKET
- ROOFTOP UNIT
- ROOFCURB
- ROOF FLASHING*
- ROOFING*
- CANT STRIP*
- ROOF DECK*
*BY CONTRACTOR
**FOR INSTALLATION OF DUCT AS SHOWN, USE RECOMMENDED DUCT SIZES FROM ROOFCURB
INSTALLATION INSTRUCTIONS. FOR DUCT FLANGE ATTACHMENT TO UNIT. SEE UNIT
INSTALLATION INSTRUCTIONS FOR RECOMMENDED DUCT SIZES.
Illustration
ST-A0743-02
ROOFCURB INSTALLATION
Illustration
ADS-106190-01
[ ] Designates Metric Conversions
INTEGRATED AIR & WATER