Rheem Manufacturing Renaissance RACD Series Line Package Air Conditioner Instructions

June 12, 2024
Rheem Manufacturing

Unit Features & Benefits

RACD Series
FACTORY INSTALLED OPTIONS:
  • Louvered panels
  • Hinged access doors
  • PlusOne® HumidiDry® Dehumidification System (ZS/ZT)
  • Low ambient/ freeze stat
  • Non-powered convenience outlet
  • Economizer (Title 24 and ASHRAE 90.1 2013 Compliant)
  • Supply and return smoke detector
  • Return smoke detector
  • ElectroFin® E-Coat for Microchannel Condenser Coil
  • ClearControl™ Direct Digital Control (DDC)
  • Comfort Alert/Phase monitor
  • Vertical economizer
FIELD INSTALLED ACCESSORY EQUIPMENT:

Accessory

| Model Number|

Factory Installation Available?

---|---|---
Economizer w/Single Enthalpy (Downflow)| RXRD-01MDDAM3|

Yes

Economizer w/Single Enthalpy (Horizontal)| RXRD-01MDHAM3|

No

Economizer-w/Single Enthalpy (Downflow) DDC| RXRD-01MDDBM3|

Yes

Economizer w/Single Enthalpy (Horizontal) DDC| RXRD-01MDHBM3|

No

Dual Enthalpy Kit| RXRX-BV01|

No

Dual Enthalpy Kit DDC| RXRX-BV02|

No

Carbon Dioxide Sensor (Wall Mount) | RXRX-AR02|

No

Power Exhaust| RXRX-CDF01C |

No

Power Exhaust| RXRX-CDF01D|

No

Manual Fresh Air Damper| RXRF-ADA1|

No

Motorized Fresh Air Damper | RXRF-ADB1 |

No

Motorized Fresh Air Damper (DDC)| RXRF-ADC1|

No

Roofcurb, 14″| RXKG-DDD14|

No

Roofcurb, 24″| RXKG-DDD24|

No

Roofcurb Adapter| RXRX-DDCAE|

No

Concentric Diffuser 7.5/8.5 Ton Flush| RXRN-AEF2000|

No

Concentric Diffuser 10.0 Ton Flush| RXRN-AEF3415|

No

Concentric Diffuser 12.5 Ton Flush| RXRN-AEF3618|

No

Concentric Diffuser 7.5/8.5 Ton Drop| RXRN-AED2000|

No

Concentric Diffuser 10.0 Ton Drop| RXRN-AED3415|

No

Concentric Diffuser 12.5 Ton Drop| RXRN-AED3618|

No

Concentric Adapter 7.5/8.5 Ton Drop| RXMC-DD01|

No

Concentric Adapter 10 Ton Drop| RXMC-DD02|

No

Concentric Adapter 12.5 Ton Drop| RXMC-DD03|

No

Outdoor Coil Louver Kit – ACD/090/102/120| RXRX-ADD04A|

Yes

Outdoor Coil Louver Kit – ACD150| RXRX-ADD04B|

Yes

Unwired Convenience Outlet| RXRX-BN01|

Yes

Unfused Service Disconnect| RXRX-BP01|

Yes

Comfort Alert (1 Per Compressor)| RXRX-AZ01 DDC|

Yes

Comfort Alert (1 Per Compressor)| RXRZ-AZ02|

Yes

BACnet Communication Card| RXRX-AY01|

No

LonWorks Communication Card| RXRX-AY02|

No

Room Humidity Sensor| RHC-ZNS4|

No

Room Temperature and Relative Humidity Sensor| RHC-ZNS5|

No

Low-Ambient Control Kit| RXRZ-A04|

Yes

Freeze Stat Kit| RXRX-AM01|

Yes

Variable Frequency Drive Kit*

*See model number break down below 

| RXRX-AC02|

No

RXRX-AC03|

No

RXRX-AC05|

No

RXRX-AD02|

No

RXRX-AD03|

No

RXRX-AD05|

No

RXRX-CC02|

No

RXRX-CC03|

No

RXRX-CC05|

No

RXRX-CD02|

No

RXRX-CD03|

No

RXRX-CD05|

No

Electric Heater Kits| RXJJ-DD10CP|

Yes

RXJJ-DD15CP |

Yes

RXJJ-DD20CP|

Yes

RXJJ-DD30CP|

Yes

RXJJ-DD40CP |

Yes

RXJJ-DD10DNV|

Yes

RXJJ-DD15DNV|

Yes

RXJJ-DD20DNV|

Yes

RXJJ-DD30DNV|

Yes

RXJJ-DD40DNV|

Yes

Single Point Wiring Kit*| RXJX-AC0605|

No

RXJX-AC0805|

No

RXJX-AD0605|

No

RXJX-AC0909|

No

RXJX-AD0609|

No

See single point wiring kit model nomenclature on page 83.
Variable Frequency Drive Kit model nomenclature on page 83.

Accessory

| Model Number| Shipping Weight Lbs. [kg]| Installed Weight Lbs. [kg]|

Factory Installation Available?

---|---|---|---|---
Economizer w/Single Enthalpy (Downflow)| RXRD-01MDDAM3|

86 [39.0]

| 57 [25.9]|

Yes

Economizer w/Single Enthalpy (Horizontal)| RXRD-01MDHAM3|

84 [38.1]

| 55 [24.9] |

Yes

Economizer-w/Single Enthalpy (Downflow) DDC| RXRD-01MDDBM3|

86 [39.0]

| 57 [25.9] |

No

Economizer w/Single Enthalpy (Horizontal) DDC| RXRD-01MDHBM3|

84 [38.1]

| 55 [24.9] |

No

Dual Enthalpy Kit| RXRX-BV01|

1 [.5]

| 1 [.5]|

No

Dual Enthalpy Kit DDC| RXRX-BV02|

1 [.5]

| 1 [.5]|

No

Carbon Dioxide Sensor (Wall Mount)| RXRX-AR02|

3 [1.4]

| 2 [1.0] |

No

Power Exhaust| RXRX-CDF01C|

58 [26.3]

| 48 [21.8]|

No

Power Exhaust| RXRX-CDF01D |

50 [22.7]

| 44 [20.0] |

No

Manual Fresh Air Damper| RXRF-ADA1|

15 [6.8]

| 12 [5.4]|

No

Motorized Fresh Air Damper| RXRF-ADB1|

38 [17.2]

| 31 [14.06]|

No

Motorized Fresh Air Damper (DDC)| RXRF-ADC1 |

38 [17.2]

| 31 [14.06] |

No

Roofcurb, 14″| RXKG-DDD14|

109 [49.4]

| 104 [47.2] |

No

Roofcurb, 24′| RXKG-DDD24|

145 [65.8]

| 140 [63.5]|

No

Roofcurb Adapter| RXRX-DDCAE|

235 [106.6]

| 215 [97.5]|

No

Concentric Diffuser 7.5/8.5 Ton Flush| RXRN-AEF2000|

235 [106.6]

| 215 [97.5] |

No

Concentric Diffuser 10.0 Ton Flush| RXRN-AEF3415|

30 [13.6]

| 25 [11.3] |

No

Concentric Diffuser 12.5 Ton Flush| RXRN-AEF3618|

250 [113.4]

| 130 [59]|

No

Concentric Diffuser 7.5/8.5 Ton Drop| RXRN-AED2000|

275 [124.7]

| 170 [77.1] |

No

Concentric Diffuser 10.0 Ton Drop| RXRN-AED3415|

35 [15.9]

| 30 [13.6] |

No

Concentric Diffuser 12.5 Ton Drop| RXRN-AED3618|

270 [122.5]

| 160 [72.6] |

No

Concentric Adapter 7.5/8.5 Ton Drop| RXMC-DD01|

300 [136.1]

| 180 [81.6] |

No

Concentric Adapter 10 Ton Drop| RXMC-DD02|

25 [11.3]

| 20 [9.1] |

No

Concentric Adapter 12.5 Ton Drop| RXMC-DD03|

75 [34]

| 65 [29.5] |

No

Outdoor Coil Louver Kit – ACD/090/102/120| RXRX-ADD04A|

52 [23.6]

| 47 [21.3] |

Yes

Outdoor Coil Louver Kit – ACD150| RXRX-ADD04B|

43 [19.5]

| 39 [17.7] |

Yes

Unwired Convenience Outlet| RXRX-BN01|

2 [1.0]

| 1.5 [.7]|

Yes

Unfused Service Disconnect | RXRX-BP01|

10 [4.5]

| 9 [4.1] |

Yes

Comfort Alert (1 Per Compressor)| RXRX-AZ01 DDC|

3 [1.5]

| 2 [0.9] |

Yes

Comfort Alert (1 Per Compressor)| RXRX-AZ02|

3 [1.5]

| 2 [0.9] |

Yes

BACnet Communication Card| RXRX-AY01|

1 [0.5]

| 1 [0.5]|

No

LonWorks Communication Card| RXRX-AY02|

1 [0.5]

| 1 [0.5]|

No

Room Humidity Sensor| RHC-ZNS4|

1 [0.5]

| 1 [0.5]|

No

Room Temperature and Relative Humidity Sensor| RHC-ZNS5|

1 [0.5]

| 1 [0.5]|

No

Low-Ambient Control Kit| RXRZ-A04|

4 [1.8]

| 3 [1.4] |

Yes

Freeze Stat Kit| RXRX-AM01 |

2 [1.0]

| 1.5 [.7] |

Yes

[ ] Designates Metric Conversions

ROOFCURBS (Full Perimeter)
  • Rheem’s roofcurb design can be utilized on all 7.5-12.5 ton [26.4-44.0 kW] RACD.
  • Two available heights (14″ [356 mm] and 24″ [610 mm]) for ALL models.
  • Quick assembly corners for simple and fast assembly.
  • Opening provided in bottom pan to match the “Thru the Curb” electrical connection opening provided on the unit base pan.
  • 1″ [25 mm] x 4″ [102 mm] Nailer provided.
  • Insulating panels not required because of insulated outdoor base pan.
  • Sealing gasket (40′ [12.2 m]) provided with Roofcurb.
  • Packaged for easy field assembly.

Roofcurb Model

| Height of Curb
---|---
RXKG-DDD14|

14″ [356 mm]

RXKG-DDD24

|

24″ [610 mm]

  1. INSULATION*
  2. *DUCT
  3. NAILER STRIP
  4. GASKET
  5. ROOFTOP UNIT
  6. ROOFCURB
  7. ROOF FLASHING*
  8. ROOFING*
  9. CANT STRIP*
  10. ROOF DECK*

*BY CONTRACTOR
**FOR INSTALLATION OF DUCT AS SHOWN, USE RECOMMENDED DUCT SIZES FROM ROOFCURB INSTALLATION INSTRUCTIONS. FOR DUCT FLANGE ATTACHMENT TO UNIT. SEE UNIT INSTALLATION INSTRUCTIONS FOR RECOMMENDED DUCT SIZES.

Illustration
ST-A0743-02

ROOFCURB INSTALLATION

Rheem Renaissance RACD Series Line Package Air A1

Illustration
ADS-106190-01

[ ] Designates Metric Conversions

INTEGRATED AIR & WATER