CHARGE AMPS Dawn EV Charger User Manual
- June 11, 2024
- CHARGE AMPS
Table of Contents
CHARGE AMPS Dawn EV Charger
Respect the environment! Must not be discarded with household waste! This
product contains electrical or electronic components. Leave the product for
separate collection and proper treatment at a designated location e.g. the
local authority’s recycling station.
Approved in conformity with the relevant EU directives and UK legislation.
Neglecting to follow and carry out the directions, instructions and safety
precautions in this User Manual implies that any warranty provisions will be
cancelled and that Charge Amps AB can reject any and all claims for
compensation in connection with any injuries/damage or incidents – direct or
indirect – that are a result of such negligence.
Charge Amps AB does not give any warranties as to the accuracy or completeness
of this document and shall have no liability for the consequences of using
such information. Charge Amps AB reserves the right to make changes to
information published in this document without notice.
Visit www.chargeamps.com for the latest document
releases.
© Copyright Charge Amps AB. All rights reserved. Copying, amending and
translating are strictly forbidden without prior written approval from Charge
Amps AB.
Safety
WARNING: Read all instructions before installation
- Improper use may create a risk of personal injury.
- The product must only be installed by a qualified electrician in accordance with the installation manual.
- National usage requirements and restrictions apply.
- Only use this product for charging compatible electric vehicles.
- Never use an adapter between the EV socket outlet and the charging cable.
- Cord extension sets are not allowed to be used.
- Inspect the product for visible damage before use.
- Never attempt to repair or use the product if it is damaged.
- Do not immerse the product in water, subject it to physical abuse or insert foreign objects in any part of the product.
- Never attempt to disassemble the product in any way.
Technical data
- Charging mode Mode 3
- EV power supply identifier
- Metering MID certified active electrical energy meter
- Socket Type 2, 22 kW
- Rated voltage (Un) 230/400 V
- Rated insulation voltage (Ui) 250/400 V
- Rated impulse withstand voltage (Uimp) 4 kV
- Rated frequency (fn) 50 Hz
- Rated current (In) 32 A
- Rated diversity factor (RDF) 1 (can be lowered if used together with a load balancing functionality)
- Dimensions (W x D x H) 250 x 145 x 380 mm
- Characteristics of power supply and output
- AC EV supply equipment connected to AC supply network, permanently connected
- Assembly type AEVCS
- RFID Type: ISO/IEC 14443
- Typ A 13.56MHz
- Mifare
- Range: 13.553 – 13.567 MHz
- Max output: 24 dBm
- Bluetooth Type: Class 2
- Version: v4.2
- Range: 2400 – 2500 MHz
- Max output: 4 dBm
- Wi-Fi Type: 802.11 b/g/n
- Range: 2400 – 2500 MHz
- Max output: 17.5/14/12.5 dBm@802.11 b/g/n
- Cellular networks communication Type: LTE-M, eMTC*
- Supported LTE-M bands: B2, B3, B4,
- B8, B12, and B20.
- Range: 699 – 960 / 1710 – 2155 MHz
- Max output: 35 dBm@GSM, 28 dBm@ LTE
- SIM card: built-in
*Support for additional cellular standards will be available through OTA updates in later releases.
Product Overview
- A MID display
- B RFID reader
- C RFID light
- D EV socket
- E Socket lights
Package contents
- Front Cover
- Charging Unit
- Back Plate
Accessories:
Additional contents:
- 1 x RFID tag
- Quick Guide User
- Welcome letter
Use
Add RFID tag
N.B. Make sure your installer has given you the access to Charge Amps Admin
Portal to be able to manage RFID tags.
Add RFID tag using the Charge Amps cloud service:
https://my.charge.space/admin
Start and stop charging without RFID identification
- Initiate charging by connecting the EV connector to the car. Lift the EV socket lid and connect the EV plug to the EV socket.
- Stop charging by disconnecting the EV connector from the car and disconnect the EV plug from the EV socket.
Start and stop charging with RFID identification
-
Initiate charging by connecting the EV connector to the car. Lift the EV socket lid and connect the EV plug to the EV socket.
-
Briefly hold the RFID tag in front of the RFID reader to initiate charging.
If no RFID tag has been verified during the 5 minutes time window, charging needs to be initiated remotely or reactivated by unplugging and reconnecting the EV connector. -
Stop charging by disconnecting the EV connector from the car and disconnect the EV plug from the EV socket.
Cable lock
During charging the cable lock is automatically activated.
Cloud connectivity
Charge Amps Cloud and Charge Amps App are available for Charge Amps Dawn
connected to Charge Amps as the cloud provider.
Charge Amps App
Please download Charge Amps App for full control, adjusting settings and
enabling smart charging and scheduling.
Charge Amps Cloud
Please create an account in the Charge Amps Cloud to configure, control and
manage your charger via our web interface.
https://my.charge.space/userapp
Full product information
Visit www.chargeamps.com for Charge Amps Dawn
Installation Manual, Charge Amps Dawn User Manual and other product
documentation.
MID display
- Overview of the total energy (kWh) imported using the Charge Amps Dawn.
- Impulses per kWh
- MID serial number
- Legal software version and CRC
- Non-legal software version and CRC
Reset the MCB
If the MCB is installed internally of Charge Amps Dawn and the MCB is tripped,
reset the MCB by following the steps below.
Recommended tools:
A Torx 25 to unscrew the front cover
-
Using a Torx 25, untighten the lock screw by turning it counterclockwise until the front cover slightly releases from the bottom. Do not unscrew the lock screw completely.
-
Remove the front cover by a pull from the bottom.
-
Remove the rubber cap.
-
Turn the switch to an upright position using a screwdriver.
-
Put the rubber cap back in place.
-
Reassemble Charge Amps Dawn by inserting the front cover bottom flange and rotate the cover in place. Secure in place by tightening the front cover lock screw using Torx 25.
N.B. Use a max. torque of 2 Nm when tightening the screw.
Detect earth fault and test the RCD
The built-in RCD function of Charge Amps Dawn needs to be tested twice a year.
An earth fault is indicated by a steady red light on the socket lights and the
RFID lights. Test and reset the built-in RCD function by following the steps
below.
Recommended tools:
- A Torx 25 to unscrew the front cover.
- A charging cable.
- Access to an electric vehicle to start a charging session.
-
Using a Torx 25, untighten the lock screw by turning it counterclockwise until the front cover slightly releases from the bottom. Do not unscrew the lock screw completely.
-
Remove the front cover by a pull from the bottom.
-
Connect the electric vehicle to Charge Amps Dawn using the charging cable.
-
If RFID authentication is enabled, briefly hold the RFID tag in front of the RFID reader to initiate a charging session.
-
When the charging session has started, hold your finger on the test button marked ”T” for three seconds to test the RCD.
-
Charging will be aborted and a steady red light will show on the socket lights which indicates a ground fault.
-
Reset the RCD by disconnecting the charging cable from Charge Amps Dawn.
-
A steady green light will show on the socket lights which indicates the RCD has been reset.
-
Reassemble Charge Amps Dawn by inserting the front cover bottom flange and rotate the cover in place. Secure in place by tightening the front cover lock screw using Torx 25.
N.B. Use a max. torque of 2 Nm when tightening the screw.
LED indications
General
Status : Socket light : RFID light
- Ready for charging Green light Green light
- Charging Blue pulsating light No light
- Charging complete Yellow light No light
RFID tag verification
Status : Socket light : RFID light
- Waiting for RFID tag verification – White short pulsating light
- Processing RFID tag – White pulsating light
- RFID tag approved – Green pulsating light
- RFID tag not approved – Red short pulsating light
Other
Status : Socket light : RFID light
- Error Red short pulsating light Red short pulsating light
- Earth fault detected Steady red light Steady red light
- EV socket unavailable for use
- No light No light
- Firmware update Yellow pulsating light Yellow pulsating light
Maintenance
WARNING! Never spray water or any other liquid directly on the product.
- Visually check that the EV connector is free from damage.
- The outside of the product must be regularly wiped with a clean, dry cloth to remove dirt and dust.
- Do not use detergent to clean any of the product components.
Product support and service
If you have any questions or problems with the product, support is always available. To find answers to your questions most quickly: Read through the User Manual to check whether your questions are answered there.
- If your question is not answered in the User Manual, please contact support.
- If you need service or repair, start by contacting the supplier from whom you purchased the product.
- For additional information, visit chargeamps.com/support.
Warranty
As warranty terms may differ from market to market, we recommend that you contact your supplier regarding the warranty terms.
chargeamps.com
Charge Amps AB (publ) Frösundaleden 2B, 8th floor
SE–169 75 Solna, Sweden
Charge Amps UK Ltd
4th Floor, 3 More London Riverside London SE1 2AQ, United Kingdom
Doc. Nr: 130986 Rev: 01
© Copyright Charge Amps AB. All rights reserved
References
- Support - Charge Amps
- Support - Charge Amps
- my.charge.space/
- Charge Amps Admin
- My Charge Space
- Charge Amps Amp Guard - dynamic load balancing
- Charge Amps Aura dual EV charger
- Charge Amps Dawn EV charger 22 kW
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>