HUMANTECHNIK SMH0002475 Lisa RF Gateway for Smartphones

Thank you very much for purchasing the lisa RF-Gateway. We expect this product to bring you many years of reliable service. Please read this manual thoroughly in order to operate the device properly and also to become accustomed with all features of the system.

Requirements

The following conditions must be given in order for the device to function:

  • An installed Internet router with a functioning internet connection

  • The internet router must have a free LAN port

  • Within the settings of the router, DHCP must be enabled (Usualy enabled by default)

  • An Android smartphone with OS version 4.01 or higher
    or

  • An Apple iPhone with iOS 9 or higher

Scope of delivery

Please check if all following contents are included:

  • lisa RF-Gateway
  • Network cable, 2 metres
  • 5V power supply unit with Micro-USB-plug
  • This manual and a warranty card

If any parts are missing please immediately contact your dealer or the manufacturer directly.

Function

An alerting system consists of at least one transmitter and one receiver.
The lisa RF-Gateway acts as a receiver and recognises the alerts sent by the various lisa RF transmitters within the house. The lisa RF-Gateway displays these alerts and forwards them to a server on the internet, which in turn supplies the information for portable devices.
The alert can be displayed worldwide on a smartphone via an installable app. Any amount of smartphones can be assigned to one Gateway device.
Please note: An interrupted internet connection at home or the smartphone being in a location without phone reception or WiFi will result in alerts not being displayed on the smartphone.

Setup

  1. Connecting the network cable Plug the supplied network cable into the network socket located on the rear panel of the device. Plug the other end of the network cable into a free LAN port of your internet router.

2. Connecting the power supply

Connect the Micro-USB-Plug of the power supply unit with the power-in-socket located on the rear panel of the lisa RF-Gateway ein. Plug the power supply unit into a mains electricity socket.
The Gateway will configure itself automatically with the router. This procedure may take a few minutes to complete.
The lisa RF-Gateway is now ready to receive the alerts of the lisa system and to forward these in encrypted form to the internet.

3a. Download and install the app

Search and download the app »Human Technik: Alert« from the respective app store for Apple or Android devices and install it on your according device. For your convenience you will find the according QR-Codes on page 21.

3b. Android OS: App configuration

After installing, launch the app and select the settings icon . In the settings, you need to enter the ID number and code, which is unique to every lisa RF-Gateway device.
You will find the ID and code on the label underneath the device as well as on the back cover of this manual.
After entering, select »Test settings«. The message »Testing connection…« is displayed.
After the message »Test successful!« has been indicated, select »Save settings « to save the ID-number and code entry.
The app will now receive alerts from the lisa RF-Gateway.

To return back to the main alert screen without alterations, press the „back“ key of your phone.

3c. Apple iOS: App configuration

After installing the app Humantechnik:Alert for iOS, please make sure that the following entries within the subfolder „Notifications“ of the iOS-settings are enabled (green):

  • Allow Notifications
  • Show in Notification Centre
  • Sounds
  • Badge App Icon
  • Show on Lock Screen

This ensures that notifications of the Humantechnik: Alert app can reach you at any time, even on the lock screen.
Upon first launch of the app, the operating system will ask for the permission to send notifications. Please select „Allow“.

After completing the previous steps, select the settings icon .
In the settings, you need to enter the ID number and code, which is unique to every lisa RF-Gateway device (see the image on page 17).
You will find the ID and code on the label underneath the device as well as on the back cover of this manual.
After entering, select »Test settings«. The message »Testing connection…« is displayed.
After the message »Test successful!« has been indicated, select »Save settings « to save the ID-number and code entry.
The app is now ready to receive alerts from the lisa RF-Gateway.

Test button

A test alert can be triggered by pressing the test button on the front panel of the  lisa RF-Gateway. If all is correctly configured and connected, the person call alert will be displayed on the app.
Please note: According to conditions within the internet, a delay of several seconds between the triggering of an alert on the lisa system and the actual event indication on the app may occur.

Test button

A test alert can be triggered by pressing the test button on the front panel of the lisa RF-Gateway. If all is correctly configured and connected, the person call alert will be displayed on the app.
Please note: According to conditions within the internet, a delay of several seconds between the triggering of an alert on the lisa system and the actual event indication on the app may occur.

Transmission range

The radio signals of the lisa transmitters within the house are designed to have a range of 80 meters under ideal conditions.
The following conditions may result in a reduced range:
– Signal transmission through building structures or vegetation
– Interference from TVs, computer monitors and mobile phones. Under certain circumstances, this may prevent the receiver from functioning at all.
– Positioning of the transmitter at an unfavourable distance from surfaces which reflect radio waves, for example floors and walls. This may lead to the signal wave being weakened or even cancelled out by the reflected wave.
– Metallic objects reduce the range due to the shielding effect of the metal.
– Having units operating at similar frequencies located close to one another may also result in mutual interference.
– Particularly in towns and cities, there may be many other sources of radio waves which can disrupt the original signal.

Setting the radio channel

A special digital transmission processensures that the radio signals are picked up without errors. This process also makes it possible to set 10 different radio channels. When supplied from the factory, all lisa RF devices are set to channel 0 by default.
It is only necessary to alter this setting to another channel number if you have several different users operating individual lisa systems in the same building.
Please disconnect the device from the power supply before attempting to change the channel.
Set the required channel by turning the channel selector switch with a small screwdriver.
All transmitters and receivers within a system must be set to the same channel number.

Internet/Server-Status-LED

LED is on: Internet- and server connection is established and active.
LED is blinking: No internet connection. Please check the network cable connection or the DHCP-setting of your internet router. (DHCP must be enabled).

Placing the Gateway

The lisa RF-Gateway should be placed in the vicinity of the internet router. During the setup, please note the following:
– The Gateway should not be placed in proximity to strong sources of interference like TV-sets, computer monitors or mobile phones.
– The Gateway should not be placed on metal surfaces and objects, as the incoming signal strength can be weakened by the metal’s shielding effect.

QR-Codes for app stores

For a convenient access to the according app providers you can also use the following QR-Codes:

Notes on data usage

In order for the lisa-Gateway to function It is necessary to transmitt the ID, the code, the point of time and the type of alert to the server. No further data is transmitted.
The alerts are stored for 30 days, after which they are automatically deleted. Users of Apple-devices receive their alerts also over the Apple push- notification servers to their units.

All lisa-devices do no

Maintenance and care

t require any maintenance. If the unit does become dirty, simply wipe it clean with a soft, damp cloth. Never use spirits, thinners or other organic solvents.
Do not set up the Gateway where it will be exposed to full sunlight for long periods. In addition, it must be protected against excessive heat, moisture and severe mechanical shocks.

Note:

This product is not protected against splash water. Do not place any containers filled with water, such as flower vases, or anything with an open flame, such as a lit candle, on or near the product.

Warranty

The lisa RF-Gateway is a very reliable product. Should a malfunction occur despite the unit having been set up and operated correctly, please contact your dealer or the manufacturer directly. This warranty covers the repair of the product and returning it to you free of charge. It is recommended that you send in the product in its original packaging, so keep the packaging for the duration of the warranty period.
The warranty does not apply to damage caused by incorrect handling or attempts to repair the unit by people not authorised to do so (destruction of the seal on the unit).
Repairs will only be carried out under warranty if the completed warranty card is returned accompanied by a copy of the dealer’s invoice/till receipt.

Always specify the product number in any event.

Disposal of used electric and electronic units (applicable in the countries of the European Union and other European countries with a separate collection system). The symbol on the product or the packaging
indicates that this product is not to be handled as ordinary household waste but has to be returned to a collecting point for the recycling of electric and electronic units.
Help to protect the environment and health of your fellow men by the correct disposal of this product. Environment and health are endangered by careless disposal. Material recycling helps to reduce the consumption of raw material.
You will receive further information on the recycling of this product from your local community, your communal disposal company or your local dealer.

Specifications

Power supply: 5V power supply unit with Micro-USB-connector
Receiver frequency: 868.35 MHz
Operating temperature: 0° C – 40° C
Height: 42 mm
Width: 119 mm
Depth: 138 mm
Weight: 260 g

This device complies with the following EC directives:
– 2011 / 65 / EC RoHS-directive
– 2012 / 19 / EC WEEE-directive
– 2014 / 53 / EC RED-directive

Compliance with the directives listed above is confirmed by the CE seal on the device. CE compliance declarations are available on the Internet at www.humantechnik.com.
Technical specifications subject to change without prior notice.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals