DUCO L2003463-A Ventilation Box for Renovation Instruction Manual

May 15, 2024
Duco

DUCO LOGO Installation manual
CO₂Box sensor (DucoBox Reno)
L2003463-A 18.01.2024

L2003463-A Ventilation Box for Renovation

Video instructions www.duco.tv

DUCO L2003463 A Ventilation Box for Renovation - QR
Code https://link.duco.eu/c6429eDUCO L2003463 A Ventilation Box for
Renovation

CO₂ MOUNTING AND CONNECTION

Box sensors can be integrated into a DucoBox Reno and provide CO₂ measurement in an air duct.
A DucoBox Reno can contain a maximum of one CO₂ Box sensor.

CO₂ BOX SENSOR – MOUNTING + CONNECTION

  1. Disconnect the DucoBox Reno from the mains and remove the lid of the DucoBox Reno. To do this, first remove the screw located behind the cover plate. (Figure 1: Remove the cover plate and unscrew the lid).
  2. Disconnect the motor plate by unclipping the 4 clamps. To do this, slide a flat screwdriver behind the clamp and tilt it back a little (approx. 5 mm) so that the clamp is released from the opening in the casing (see Figure 2: detaching motor plate and Figure 3: removing motor plate).
  3. Attach the CO₂ Box sensor from the outside into the desired spigot by clicking it on the rib closest to the motor plate (Figure 4: Snap the CO₂ Box sensor into the spigot). To do this, make a tilting movement by first tightening the lower and then the upper clamp.
  4. Thread the CO₂ Box sensor cable through the opening on the inside of the casing at the level of the corresponding spigot. Then pull the cable from the CO₂ Box sensor through the relevant opening (marked ‘sensor cable’) of the motor plate according to the diagram shown below in Figure 5: four options for wiring a maximum of 1 CO₂ Box sensor to the printed circuit board.
  5. Attach the motor plate to the casing. The motor plate is fixed when the 4 clamps are engaged in the casing. Make sure that the strain relief of the power cable is pushed into the opening provided for this purpose. The power cable can be attached to the outside of the casing by using the cable clips.
  6. Connect the CO₂ Box sensor to the connector (CO₂) on the printed circuit board of the DucoBox Reno (see DucoBox Reno installation manual).
  7. Mount the lid correctly on the unit. Make sure the notch in the lid is over the power cable opening (Figure 6: Note the notch in the lid). Screw the lid back on and close with the cover plate.

DUCO L2003463 A Ventilation Box for Renovation -
FIGUREDUCO L2003463 A Ventilation Box
for Renovation - FIGURE 2

LEGISLATION

The CO₂ Box sensor is an (optional) part of the DucoBox Reno.
Product card, EC declaration of conformity and energy labels can be viewed and downloaded at www.duco.eu.

Translation of the original instructions See www.duco.eu for information regarding warranty, maintenance, technical data, etc. Installation, connection, maintenance and repairs should be done by a recognised installer. The electronic components of this product may be live. Avoid contact with water.

DUCO L2003463 A Ventilation Box for Renovation - Symbol
2 Vero DUCO – Handelsstraat 19 – 8630 Veurne – Belgium
tel +32 58 33 00 33 –[email protected]www.duco.eu
L2003463- A 18.01.2024

Documents / Resources

| DUCO L2003463-A Ventilation Box for Renovation [pdf] Instruction Manual
L2003463-A Ventilation Box for Renovation, L2003463-A, Ventilation Box for Renovation, Box for Renovation, Renovation
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals