Product Information
Part Number | Description | Quantity |
---|---|---|
FCS9N-12-10R | OPTICOMTM SPLICE CASSETTE BASE | 1 |
FCS9N-12-10P | OPTI-COMTM SPLICE CASSETTE COVER | 1 |
FCS9N-12-LAR | CASSETTE PERFORMANCE LABEL | 1 |
FCS9N-12-LAP | #6-32 X 1/4 FLAT HEAD PHILLIPS SCREW | 3 |
FCSZO-12-10R | SPLICE CHIP | 1 |
FCSZO-12-10P | SPLICE CHIP ADHESIVE TAPE | 1 |
FCS9N-12-03P | PLT1.5I-M CABLE TIE | 2 |
FCS9N-12-SAP | SPLICE PROTECTOR FOR FIBER | DEPENDENT ON P/N |
FCSZO-12-03P |
WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION.
MAINTAIN DUST CAPS ON UNMATED CONNECTORS.
CAUTION: Fiber optic cable is sensitive to excess pulling, bending, and
crushing forces.
Consult the manufacturer’s cable specifications sheet for specific cable to
use.
For Technical Support:
www.panduit.com/resources/install_maintain.asp
Product Usage Instructions
Step 1: Remove Cover
Remove the 3 screws and cover from the Opti-ComTM Fiber Optic Splice
Cassette.
Step 2: Install Splice Chip
Using the splice chip adhesive tape, install the splice chip onto the
cassette. The splice chip can be placed in the center or in an alternative
position.
Step 3: Install Fiber
Insert the fiber into the rear of the splice chip.
Step 4: Install Cable Ties
Place the fiber cable through both sides of the heat shrink. Use cable ties
to secure the cables. Heat shrink the cables together using appropriate heat
shrinking techniques. It is possible to stack two heat shrinks per slot,
allowing for a total of 24 cables.
Step 5: Attach Heat Shrinked Cables to Connectors
Attach the heat shrinked cables to the connectors.
Step 6: Re-install Cover
Re-install the cover onto the Opti-ComTM Fiber Optic Splice Cassette using
the 3 screws.
For Instructions in Local Languages and Technical Support:
Website:
www.panduit.com/resources/install_maintain.asp
E-mail: techsupport@panduit.com
Phone: 866-405-6654
PART NUMBER | DESCRIPTION |
---|---|
FCS9N-12-10R | OPTI-COMTM OS2 SPLICE CASSETTE, DUPLEX LC, PRELOADED WITH |
12-FIBER RIBBON PIGTAIL
FCS9N-12-10P| OPTI-COMTM OS2 SPLICE CASSETTE, DUPLEX LC, PRELOADED WITH 12
PIGTAILS
FCS9N-12-LAR| OPTI-COMTM OS2 SPLICE CASSETTE, DUPLEX LC/APC, PRELOADED WTH
12-FIBER RIBBON PIGTAIL
FCS9N-12-LAP| OPTI-COMTM OS2 SPLICE CASSETTE, DUPLEX LC/APC, PRELOADED WITH 12
PIGTAILS
FCSZO-12-10R| OPTI-COMTM OM4 SPLICE CASSETTE, DUPLEX LC, PRELOADED WITH
12-FIBER RIBBON PIGTAIL
FCSZO-12-10P| OPTI-COMTM OM4 SPLICE CASSETTE, DUPLEX LC, PRELOADED WITH 12
PIGTAILS
FCS9N-12-03P| OPTI-COMTM OS2 SPLICE CASSETTE, DUPLEX SC, PRELOADED WITH 12
PIGTAILS
FCS9N-12-SAP| OPTI-COMTM OS2 SPLICE CASSETTE, DUPLEX SC/APC, PRELOADED WITH 12
PIGTAILS
FCSZO-12-03P| OPTI-COMTM OM4 SPLICE CASSETTE, DUPLEX SC, PRELOADED WITH 12
PIGTAILS
COMPONENTS
DESCRIPTION| QUANTITY
OPTICOMTM SPLICE CASSETTE BASE| 1
OPTI-COMTM SPLICE CASSETTE COVER| 1
CASSETTE PERFORMANCE LABEL| 1
6-32 X 1/4″ FLAT HEAD PHILLIPS SCREW| 3
SPLICE CHIP| 1
SPLICE CHIP ADHESIVE TAPE| 1
PLT1.5I-M CABLE TIE| 2
SPLICE PROTECTOR FOR FIBER| DEPENDENT ON P/N
WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. MAINTAIN
DUST CAPS ON UNMATED CONNECTORS.
CAUTION: Fiber optic cable is sensitive to excess pulling, bending, and
crushing forces. Consult the manufacturer’s cable specifications sheet for
specific cable to use.
Remove 3 screws and cover.Install splice chip using
splice chip adhesive tape.
Showing alternative placement for
splice chip
Install fiber into rear of splice
chip.
Install cable ties over fiber cable.
Bring cable in through both sides of
heat shrink. Heat shrink cables together using best practices for heat
shrinking. Heat shrink may be stacked two per slot for a total of 24 cables.
Attach heat shrinked cables to
connectors,
Re-install cover and 3 screws.