PedSafety RRFB Rectangular Rapid Flashing Beacon User Guide
- June 6, 2024
- PedSafety
Table of Contents
PedSafety RRFB Rectangular Rapid Flashing Beacon
![]()
Product Description
Rectangular Rapid Flashing Beacon (RRFB)
![]()
Initial Setup
✓ Use Ped Connex to set the Guardian station to RRFB mode.
✓ Use only 5 wires from the flasher cabinet to the Guardian station:
- 2 field terminals connect to PPB input inside of the flasher cabinet (12-18 VAC or VDC).
- 12 Volt and GND terminals need continuous 12VDC from the flasher cabinet.
- Both the walk and don’t walk terminals need a 12VDC signal to activate the walk message (see options A and B).
WARNING: To use Guardian in RRFB Mode, use only 1 terminal: walk or don’t walk, depending on the voltage of the flasher controller. Do not use both terminals in RRFB mode.
Option A: Using the Walk Terminal to Activate Audible Messages
✓ If the voltage from the flasher cabinet changes from 0 Volts to 12VDC when the lights are flashing, use the Walk (W) terminal on the Guardian station to obtain an audible message for WALK indication.
![]()
Option B: Using the Don’t Walk Terminal to Activate Audible Messages
✓ If the voltage from the flasher cabinet constantly switches from 0 Volts to 12VDC when the lights are flashing, use the Don’t Walk (DW) terminal on the Guardian station to obtain an audible message for WALK indication.
![]()
For specific information about the flasher controller and its functionality, contact the RRFB manufacturer directly or consult the schematics.
Doc # 906-0040 Rev B