Hanwha BFG-590 BFG Solar Module Series Instruction Manual
- June 1, 2024
- Hanwha
Table of Contents
Hanwha BFG-590 BFG Solar Module Series
Introduction
With solar modules from Hanwha Q CELLS America Inc. (hereafter referred to as “Qcells”), you can directly transform the sun’s limitless energy into environmentally friendly solar electricity. To ensure the maximum performance of your Qcells solar modules, please read the following instructions completely and carefully and observe all guidelines. Non-compliance may result in damage and/or physical injury.
- This installation manual provides instructions for the safe installation and operation of crystalline solar modules.
- Please read these instructions carefully before proceeding with your installation.
- Please retain these instructions for the life of the solar modules.
- Please ensure that this Manual is available to the operator at all times.
- This Manual should be given to all subsequent owners or users of the solar modules.
- All supplements received from the manufacturer should be included.
- Please observe all other applicable documents.
- If your questions are not satisfactorily answered in the manual, please contact your system supplier.
- Additional information can be found on our website at www.qcells.com.
Intended use
- This manual is valid in North America for Qcells solar modules.
- These instructions contain information regarding the safe handling and use of quality crystalline solar modules from Qcells and their installation, mounting, wiring, and maintenance.
Symbols and Labels
- The following symbols and labels are used throughout the Manual for ease of use.
- Beware of possible danger or damage.
Categories:
- Danger: Risk of fatal injury
- Attention: Risk of serious injury or damage to property
- Note: Risk of damage to product
Units
Where both Imperial and U.S. units (for example inches) are shown, metric
units are definitive. References to “Data Sheet” or “Module Data Sheet” refer
to the Module Data Sheet applicable to the module being used.
Safety Regulations
The installer and solar module operator are responsible for compliance with
all applicable statutory requirements and regulations. The following
regulations and standards must be upheld at all times during the installation,
operation, and maintenance of the solar modules:
- Installation and Operation Manual.
- Other applicable documents (such as country-specific regulations for pressure equipment, operational safety, hazardous goods, and environmental protection).
- Regulations and requirements specific to the system.
- Applicable country-specific laws, regulations, and provisions governing the planning, installation, and operation of solar power systems and work on roofs.
- Any valid international, national and regional regulations governing work with direct current, especially those applicable to the installation of electrical devices and systems, and regulations issued by the respective energy provider governing the parallel operation of solar power systems.
- Accident-prevention regulations.
Certified Personnel
Both, the operator and installer are responsible for ensuring that the
installation, maintenance, connection to the grid, and dismantling are carried
out by trained and qualified electricians and engineers with approved training
certificates (issued by a state or federal organization) for the respective
specialist trade. Electrical work may only be performed by a socially
certified tradesperson by the applicable safety standards, accident prevention
regulations, and the regulations of the local energy provider.
Validity
- These instructions are only valid for crystalline solar modules from the company Qcells as specified in chapter “2.1 Technical specifications”. Qcells assumes no liability for damage resulting from failure to observe these instructions.
- Please observe the wiring and dimensioning of the system.
- The installer of the system is responsible for compliance with all necessary safety regulations during set-up and installation.
- Qcells assumes no liability based on these instructions.
- Qcells is only liable in the context of contractual agreements or the context of accepted guarantees. Qcells accepts no other responsibility for the functionality and safety of the modules.
- Please observe the instructions for any other system components that may be part of the complete solar power system. It may be necessary to carry out a structural analysis of the entire project.
- If your questions are not satisfactorily answered in the manual, please contact your system supplier.
- Additional information can be found on our website at www.qcells.com.
Information for the Operator
- Please keep this manual for the entire life of the solar power system.
- Please contact your system supplier for information concerning the formal requirements for solar power systems.
- Please be sure to contact the relevant local authorities and energy providers regarding regulations and permit requirements before the installation of the solar power system. Your financial success depends on the fulfilment of these requirements.
Other applicable documents
- This installation manual is only valid in combination with the following technical information.
Document Type
- Product data sheet
- Packaging and transport information
MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER INSTALLATION OR CONFIGURATION, IMPROPER MAINTENANCE, UNINTENDED USE, AND UNAUTHORIZED MODIFICATION.
Attention: This marking indicates that this product should not be disposed of with other household waste within the EU. Recycle this product properly to prevent possible damage to the environment or a risk to human health via uncontrolled waste disposal and to promote the sustainable reuse of material resources. Please return your used product to an appropriate collection point or contact the retailer where you purchased this product. Your retailer will accept used products and return them to an environmentally sound recycling facility.
Planning
Technical specifications
For additional information see the relevant datasheet of the module provided at www.qcells.com.
Fig. 1: External dimensions and components for Q.PEAK DUO XL-G11S.3 / BFG, Q.PEAK DUO XL-G11S.7 / BFG.
Requirements
Installation Site
Please note the following guidelines that apply to the installation site:
- Solar modules are not explosion-proof and are not suitable for use in explosive environments.
- Do not operate solar modules near highly flammable gas and vapours (e.g. gas tanks, and gas stations).
- Do not install modules in enclosed spaces.
- Do not install modules in locations where they may be submerged in water (e.g. floodplains).
- Do not use modules as a substitute for the normal roofing (e.g. modules are not watertight).
- Do not install modules near air conditioning systems.
- Do not install modules above 13,120 ft (4,000 m) altitude above sea level.
- Contact with saline water (e.g. spray water from the sea) and salt aggregation on the modules must be avoided.
- Do not bring any chemical substance (e.g. oil, solvent etc.) into contact with any part of the panel. Only substances, that are released by Qcells, are allowed to be used during installation, operation and maintenance.
- Any installation of modules on surfaces of water is prohibited.
- This includes installations on floating as well as pile-based platforms. Qcells may extend the coverage of its warranty to such installations, based on a case-by-case assessment of the system design and location. Prior written consent by the warrantor is required in any case.
Prevention of Shadowing Effects
Optimal solar irradiation leads to maximum energy output:
- For this reason, install the modules so that they face the sun.
- Avoid shadowing (due to objects such as buildings, chimneys or trees).
- Avoid partial shading (for example through overhead lines, dirt, snow).
Limitations
The solar modules are designed for the following applications:
- Operating temperatures from –40 °F to +185 °F.
- Pull loads and push loads according to Chapter 2.3 (‘Test Load’ by IEC 61215 and ‘Design Load ×1.5’ by UL 61730).
- Installation using a mounting structure for solar modules.
Mounting Structure Requirements
Requirements for the mounting structure:
- Conform to the necessary structural requirements.
- Compliant with local snow and wind loads.
- Properly fastened to the ground, the roof, or the façade.
- Forces acting on the module are relayed to the mounting substructure.
- Ensures sufficient rear ventilation of the module.
- Avoid the usage of different metals to prevent contact corrosion.
- Allows for stress-free expansion and contraction due to temperature fluctuations.
- Ensure that no additional forces are applied through the mounting system into the module except for the wind and snow loads. Additional forces and moments of torque at the mounting positions caused by torsions, displacements or vibrations in the mounting system are not allowed.
- Ensure that the clamps and the mounting frame are compatible.
Clamp System Requirements & Recommendations
Use customary clamps that satisfy the following requirements:
- Clamps are not in contact with the front glass laminate.
- Clamps do not deform the frame.
- Clamps that satisfy the structural requirements based on the conditions of the installation site according to the applicable regulations and technical standards.
- Long-term stable clamps that securely affix the module to the mounting frame.
- Front side clamp height complaint with the module frame height.
Flange Clamp Requirements
- Flange clamps must not touch the laminate even under load.
- Clamping at the long module sides only.
- Flange clamps type A (Fig. X):
- Clamp width: ≥ 0.71 in (18 mm)
- Clamp depth: ≥ 0.39 in (10 mm)
- Contact area: ≥ 0.062 in2 (40 mm2)
- The flange clamps type A must contact the flange at least as marked in fig. X (contact width: ≥ 0.07 in (2 mm)).
- Flange clamps type B (Fig. Y):
- Clamp depth: ≥ 0.12 in (3 mm)
- Contact area: ≥ 0.155 in2 (100 mm2)
- Clamp position: contact area ≥ 0.39 in (10 mm) away from flange edge.
- For more details regarding flange clamps type B see fig. Y
- Flange clamps type C (Fig. Z):
- Clamp diameter: ≥ 0.62 in (15.8 mm)
- Contact area: ≥ 0.219in2 (141 mm2) completely flat on the frame flange.
- Clamp position: centre of contact area in the axis of the mounting slots (Detail A, Fig.1) or closer to the hollow chamber.
- For more details regarding flange clamps type C see fig. Z.
- Maximum pull design loads: minimum of selected mounting option and FB mounting options (see section “Mounting options with bolts” of chapter “2.3 Mounting options”).
Module Orientation Requirements
- Vertical or horizontal installation is permitted.
- Ensure that rain and melting snow can run of freely. No water accumulation.
- Ensure that the drainage holes in the frame are not covered. No sealing.
Mounting options REQUIREMENTS OF ALL MOUNTING OPTIONS
- The loads in the table are related to the mechanical stability of the solar modules. The mounting system and installation equipment (clamps, etc.) are not part of the PV module certification acc. IEC 61215 / 61730. The mechanical stability of the mounting system including clamps has to be evaluated by the system supplier. The listed test load values have been determined with special reusable test clamps with high stiffness to be able to apply maximum stress to the module components during the test. The installer has to make sure that the used clamps are capable of securely fastening the module under the specified maximum loads.
- The system installer is responsible for the determination of location-specific load requirements.
- Ensure that the connection cables of the junction box do not run between laminate and mounting rails.
- Modules bend under load. Therefore, sharp objects (e.g. screws, ballast stones, rail ends, rails with burrs or sharp corners) must not be placed near the module backside so as not to touch the laminate under load.
- Ensure that the junction boxes do not touch the mounting structure (e.g. shorts rails, ballast, etc.) or the rooftop under load.
- Clamps or insertion profiles etc. must not touch the glass (even under load).
- Unbalanced loads (e.g. snow overhangs, snowdrifts) that result in locally significantly increased loads must be removed or avoided by technical measures.
- A minimum support depth of 0.59 in (15 mm) is required on the back side of the module
Loads according to IEC 61215-2:2016 and UL 61730-2:2017 except for design
loads lower than 1600 Pa which do not fulfill the requirements of the
standards. The test procedure is always according to IEC 61215-2:2016. Design
loads result from the safety factor 1.5.
Mounting options with clamps
The illustrated installation options apply to both horizontal and vertical module orientation
Mounting options
Mounting options with bolts The illustrated installation options apply for both horizontal and vertical module orientation.
Tracker mounting options
Specifications for TB1a, TB1b, TB2a, TB2b and TC1 Mounting Options
NOTE! For a requested push load maintain a minimum distance (clearance) between the bottom module plane (level of bottom frame leg) and the closest substructure element below the solar module laminate. The minimum clearance is defined by the maximum test push load and the limited area where the substructure element is located beneath the module (see Figures 2 and 3).
Electrical layout
Module Selection
- For detailed key electrical data, please refer to the actual data sheet referring to the relevant Module (available at www.qcells.com).
- For maximum energy yields, mismatches of specified electric current (IMPP) of more than 5 % should be avoided for all modules connected in series.
Safety Factor
During normal operation, a module may generate a greater current and/or higher
voltage than that determined under standardized test conditions. Accordingly,
the values of ISC and VOC marked on the module should be multiplied by a
factor of 1.25 when determining:
- the component voltage ratings,
- conductor ampacities,
- fuse sizes,
- size of controls connected to the PV output.
Refer to Section 690-8 of the National Electrical Code for an additional multiplying factor of 125 per cent (80 per cent derating) which might be applicable. Please follow the valid national guidelines for the installation of electrical systems (refer to section 690-8 of the NEC for an additional multiplying factor of 125 per cent [80 per cent derating] which may be applicable).
Series Connection
- Connection of modules in series is only permitted up to the maximum system voltage as listed in the applicable datasheet.
- Take into account all possible operating situations and all relevant technical norms and regulations when designing the system. It has to be ensured that the maximum system voltage, including all necessary safety margins, is not exceeded.
- Take the voltage limit of the inverter into account when determining the maximum number of modules in the string
Parallel Connection
- Modules may be damaged by the occurrence of reverse currents (caused by module defects, ground leaks, or defective insulation).
- Ensure that the maximum reverse current load capacity indicated in the data-sheet is met.
- To limit reverse currents that may occur, we recommend using the following safety options:
- Layout with a limited number of parallel connected strings:
- Without undertaking further current blocking measures, a maximum of two module strings may be operated in parallel on a single inverter or MPP tracker.
- Layout with string fuses:
- Use overcurrent devices (e.g. fuses) according to the relevant standards in each string. Use gPV-fuses according to IEC 60269- 6. Observe the maximum permitted number of strings as indicated in the specifications provided by the respective string fuse manufacturer and the technical guidelines.
NOTE!
- When installing different product versions, the lowest minimum permitted reverse current load capacity applies.
Inverters
- Inverters with or without transformers may be used.
Installation
Safety and transport
Preparation of installation
Module installation
Electrical Connection
Safety
- Danger! Risk of fatal injury due to electric shock!
- When disconnecting an electric circuit carrying direct current, electric arcs can occur that may result in life-threatening injuries.
- Do NOT unplug the cable when under load.
- Do NOT connect any exposed cable ends.
- Electrical work may only be performed by qualified and skilled personnel (see page 3).
- A solar module generates electrical current and voltage even at a low intensity of illumination. Sparks and electric arcs may result from the separation of a closed circuit. These can result in life-threatening injuries. The danger increases when several modules are connected in series.
- Please be aware that the entire open circuit voltage is active even at low levels of solar irradiation.
- Please follow the valid national regulations and safety guidelines for the installation of electrical devices and systems.
- Please make sure to take all necessary safety precautions.
- With module or phase voltages of more than 120 V, the safety extra-low voltage range is exceeded.
- Carry out work on the inverter and the wiring with extreme caution.
- Ensure that the modules are disconnected at the inverter before separation.
- Be sure to observe the time intervals specified by the inverter manufacturer after switching off the inverter.
- Make sure that the plugs can not be connected unintentionally.
- Before working on the contacts, check them for safety extra-low voltage.
Electrical installation safety
Connection of modules
After installation
Grounding
Protective Grounding
- To prevent electrical shock or fire, the frame of the module as well as any non-current-carrying metal parts of the system must be grounded. While this section provides some information about grounding the Qcells frames and modules, reference should be made to local statutes and regulations for specific requirements on grounding. The U.S. National Electrical Code addresses these issues in Article 250. A module with exposed conductive parts is considered to comply with this standard only when it is either electrically grounded following the manufacturer’s instructions and the requirements of the National
- Electrical Code, ANSI/NFPA 70 (2014-2017), or when the bonding means has been evaluated with this module to UL 2703.
- Proper grounding is achieved by bonding all exposed non-current carrying metal equipment to the appropriately sized equipment grounding conductor (EGC) or racking system that can be used for integrated grounding.
- Qcells frames are protected from corrosion with an anodized coating, which has to be penetrated to ensure proper bonding. The different methods listed below are suggested methods for an appropriate bond between the frame and the EGC or racking system (that will have to be properly grounded). The method appropriate for any individual installation will depend on multiple factors.
Option A: Use of a grounding lug
- A listed grounding lug can be bonded to the frame using the grounding holes pre-drilled in the frame. These holes are marked with a ground symbol, as shown below on the frame section drawing: To install the grounding lug, follow the specified instructions of the manufacturer. The grounding lug should be made of stainless steel or tin-plated metals such as aluminium to avoid corrosion.
- The grounding lug should be attached to the frame grounding hole using a stainless steel screw, toothed lock washer or KEPS nut (to penetrate the anodized layer) and backing nut. Care should be taken to avoid the use of grounding hardware of dissimilar metals, which may lead to corrosion.
Option B: Integrated grounding methods
- The Qcells modules can be bonded with the racking system using UL1703 or UL2703-certified integrated grounding methods.
- The racking system will then have to be grounded so that the overall system is properly grounded. The listed racking system and grounding device should be installed according to the manufacturer’s instructions. An example of such an integrated grounding method is the use of a WEEB clip or Schletter plate between the module and the racking system when mounting the module.
- The WEEB washers are generally compatible with Qcells modules, however, each combination module/racking system requires a specific WEEB washer size. Note that WEEB clips are intended for single use only; they must not be reused after removal or loosening. Refer to Wiley’s installation instructions for the specific use of WEEB washers.
- An example of such an integrated grounding method is the use of a washer recognized as meeting UL2703 requirements between the module and the racking system when mounting the module.
- For example, WEEB washers are generally compatible with Qcells modules, however, each combination module/racking system requires a specific WEEB washer size. Note that WEEB washers are intended for single use only; they must not be reused after removal or loosening. Refer to Wiley’s installation instructions for the specific use of WEEB washers.
Faults and defects
Danger!
- Risk of fatal injury due to electric shock!
- Do not attempt to fix any problems yourself (e.g., glass cracks, or damaged cables).
- Please contact an installer or Qcells Technical Customer Service Department.
Disposal
- Do not disconnect modules by yourself.
- Please commission a trade specialist.
- Dispose of modules by the local disposal regulations.
Maintenance and cleaning
- Qcells solar modules are known for a long operating life and minimal maintenance eort and expense. Dirt and grime are usually washed away by rain. If the module is fully or partially shaded by dirt or debris (e.g., plants, bird droppings), it needs to be cleaned to prevent a loss of performance.
Maintenance
- The PV system has to be inspected regularly by certified personnel.
- The time intervals and extent of the inspection can depend on local circumstances (e.g. salt, ammonia content in the air, high humidity etc.). The customer/operator must inform himself about time intervals and the extent of necessary inspections.
- Inspections have to be performed especially after extraordinary events (e.g. storms, hail, high snow loads etc.)
- During the inspections, it has to be checked that the components are secure, undamaged and clean.
Cleaning
- WARNING!
- Risk of injury due to hot and live modules!
- Only clean modules that have cooled down.
- Do not carry or wear any electrically conductive parts.
- WARNING!
- Risk of falling due to unsecured access!
- Never access the installation area alone or without taking adequate security precautions.
- Please commission a trade specialist.
- NOTE!
- Module surface damage may occur!
- Remove snow and ice carefully without force (e.g. with a very soft broom).
- Do not scratch of dirt.
- Module cleaning has to be done by qualified personnel according to the state of the art and taking into account all relevant safety issues and general product properties, e.g., but not restricted to:
- electrical safety
- mechanical stability (load limits depending on the actual mounting options)
- chemical suitability (no effect on any of the module‘s components, e.g. cable, connector, silicone)
- no abrasive materials.
- NOTE!
- Dust and dirt are abrasive materials!
- The situation for each project (or type of dirt) must always be professionally evaluated.
- Wrong cleaning may cause damages such as, but not limited to, damages to the glass surface (e.g. scratches) and AR coating, power loss, delamination, loss of frame-to-laminate bond, reduced snow and wind load capability etc.
- Apart from the above, each customer is free to choose the method of cleaning. However, possible damages, caused by the cleaning or related to the cleaning tools or agents shall not be covered by the module‘s Product and Performance Warranty.
- Therefore it is recommended to use only the tools and agents that have already been successfully tested and used with PV modules, to prevent possible damage.
- Isopropyl alcohol (IPA) can be used selectively to remove stubborn dirt and stains within one hour after emergence.
CONTACT
-
HANWHA Q CELLS AMERICA INC.
400 Spectrum Center Drive Suite 1400 Irvine, CA 92618 USA -
EMAIL hqc-inquiry@qcells.com.
-
WEB www.qcells.com.
-
TEL +1 949 748 59 69
Subject to change without notice. © Qcells Installation manual solar modules Q.PEAK DUO XL-G11S.X / BFG_modules_series_2023-12_Rev10_NA INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G11S.X / BFG