PedSafety Guardian Wave Pedestrian Signal User Guide
- June 7, 2024
- PedSafety
Table of Contents
PedSafety Guardian Wave Pedestrian Signal
Specifications
Component | Specification |
---|---|
Input Warning | 120VAC input or 48VDC input |
Output | 12 VDC outputs |
Wire Colors | Blue to Walk, White to Neutral, Orange to Don’t Walk |
SPI Terminals | Terminal 4: +12VDC, Terminal 3: -GND, Terminal 2: S2 W (Walk), |
Terminal 1: S1 DW (Don’t Walk)
Guardian Connections| +12VDC, -GND, W (Walk), DW (Don’t Walk)
Cable Type| 18 Gauge 4 Conductor Shielded Cable (12VDC Low Voltage Connection)
Recommendation for New Installations| IMSA 14-gauge (loop detector wire)
Technical Support and Documentation
- For complete documentation, visit PedSafety Installation Guides and refer to the PedConnex Utility Manual, pages 10-11. For assistance, call Tech Support at 208-345-7459, option 2.
FAQ
What should I do if I have a 48VDC intersection?
A different SPI is required for 48VDC intersections compared to 120VAC intersections.
How do I connect the SPI in the Pedestrian Signal Head?
Connect the blue wire to Walk, white wire to Neutral, and orange wire to Don't Walk. Ensure that the SPI is not set on the bottom and that its terminals are connected to the corresponding terminals on the Base Station.
What happens if the Guardian is installed upside down?
The warranty for the Guardian/Guardian Wave is void if the unit is installed upside down.
What type of wire is recommended for new intersection installations?
PedSafety recommends IMSA 14-gauge wire (loop detector wire) for new intersection installations, in the absence of city or other local specifications.
Where can I find complete documentation for installation?
Complete documentation can be found at the PedSafety Product Installation Guides website, specifically in the PedConnex Utility Manual on pages 10-11.
Quick Wiring Guide
- SPI (Signal Power Interface) in the Pedestrian Signal Head
Warning 120VAC input or 48VDC input
Cabinet Connection
- Utilizes the existing field wires from cabinet to pedestrian push buttons to place calls
- NOT polarity dependent
- Field Wires only required for intersections not in the recall
Note: For NEW intersection installations, in the absence of city or other local specifications, PedSafety recommends IMSA 14-gauge (loop detector wire).
Guardian/ Guardian Wave
- Warranty void if Guardian is installed upside down
Wiring
- Guardian Wiring Connections (Enhanced view of terminal block in front)
CONTACT
- For complete documentation visit https://www.pedsafety.com/product-installation-guides/ and refer to the PedConnex Utility Manual
- Tech Support: 208-345-7459